SELF-ABSORPTION CORRECTIONS FOR WELL-TYPE GERMANIUM DETECTORS

被引:198
|
作者
APPLEBY, PG
RICHARDSON, N
NOLAN, PJ
机构
[1] UNIV LIVERPOOL,DEPT PHYS,LIVERPOOL L69 3BX,ENGLAND
[2] UNIV LIVERPOOL,DEPT GEOG,LIVERPOOL L69 3BX,ENGLAND
关键词
D O I
10.1016/0168-583X(92)95328-O
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Corrections for self-absorption are of vital importance to accurate determination by gamma spectrometry of radionuclides such as Pb-210, Am-241 and Th-234 which emit low energy gamma radiation. A simple theoretical model for determining the necessary corrections for well-type germanium detectors is presented. In this model, self-absorption factors are expressed in terms of the mass attenuation coefficient of the sample and a parameter characterising the well geometry. Experimental measurements of self-absorption are used to evaluate the model and to determine a semi-empirical algorithm for improved estimates of the geometrical parameter.
引用
收藏
页码:228 / 233
页数:6
相关论文
共 50 条
  • [41] EVALUATION OF WELL-TYPE GE(LI) DETECTORS FOR LOW-LEVEL RADIOCHEMICAL ANALYSIS
    BRAUER, FP
    MITZLAFF, WA
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1978, 25 (01) : 398 - 403
  • [42] Some modifications to Sima’s model for total efficiency calculation of well-type detectors
    S. Pommé
    J. Camps
    G. Sibbens
    T. Vidmar
    Y. Spasova
    Journal of Radioanalytical and Nuclear Chemistry, 2009, 281 : 143 - 147
  • [43] Some modifications to Sima's model for total efficiency calculation of well-type detectors
    Pomme, S.
    Camps, J.
    Sibbens, G.
    Vidmar, T.
    Spasova, Y.
    JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 2009, 281 (01) : 143 - 147
  • [44] TABULATED EFFICIENCIES OF SOME WELL-TYPE GAMMA RAY SCINTILLATION DETECTORS FOR VARIOUS GEOMETRIES
    SNYDER, BJ
    NUCLEAR INSTRUMENTS & METHODS, 1967, 53 (02): : 313 - &
  • [45] CALCULATED PHOTOPEAK EFFICIENCIES OF NAI(TI)-SCINTILLATION DETECTORS WITH SELF-ABSORPTION IN SOURCE
    RIEPPO, R
    NUCLEAR INSTRUMENTS & METHODS, 1973, 107 (02): : 209 - 212
  • [46] Calibration and use of well-type germanium detectors for low-level gamma-ray spectrometry of sediments using a semi-empirical method
    Diaz-Asencio, Misael
    Sanchez-Cabeza, Joan-Albert
    Carolina Ruiz-Fernandez, Ana
    Corcho-Alvarado, Jose A.
    Hascibe Perez-Bernal, Libia
    JOURNAL OF ENVIRONMENTAL RADIOACTIVITY, 2020, 225
  • [47] EXPERIMENTAL AND CALCULATED PHOTOPEAK EFFICIENCY VALUES FOR WELL-TYPE NAI(T1) DETECTORS
    CEJNAR, F
    KOVAR, I
    INTERNATIONAL JOURNAL OF APPLIED RADIATION AND ISOTOPES, 1980, 31 (02): : 79 - 84
  • [48] A WELL-TYPE GE(LI) DETECTOR
    SANTHANA.S
    MONARO, S
    BULLETIN OF THE AMERICAN PHYSICAL SOCIETY, 1968, 13 (11): : 1404 - &
  • [49] A WELL-TYPE GE(LI) DETECTOR
    SANTHANAM, S
    WEBB, PP
    MONARO, S
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1969, NS16 (01) : 75 - +
  • [50] SELF-ABSORPTION IN A RADIATING SPHERE
    BULASHEVICH, IP
    SOVIET PHYSICS-TECHNICAL PHYSICS, 1956, 1 (11): : 2512 - 2513