PIEZOELECTRIC PH SENSORS - AT-CUT QUARTZ RESONATORS WITH AMPHOTERIC POLYMER-FILMS

被引:30
|
作者
WANG, J
WARD, MD
EBERSOLE, RC
FOSS, RP
机构
[1] UNIV MINNESOTA, DEPT CHEM ENGN & MAT SCI, AMUNDSON HALL, 421 WASHINGTON AVE SE, MINNEAPOLIS, MN 55455 USA
[2] DUPONT CO INC, EXPTL STN, DEPT CENT RES & DEV, WILMINGTON, DE 19880 USA
关键词
D O I
10.1021/ac00067a002
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Piezoelectric AT-cut quartz resonators immersed in aqueous media, coated with cross-linked films of the random copolymer-{[CH2CH(CO2H)]a-[CH2-C(CH3)(CO2CH3)]b-[CH2C(CH3)(CO2CH2CH2-NMe2)]c}n (1), exhibit large frequency changes when the pH is changed in the vicinity of the isoelectric point of the polymer film. The frequency changes are attributed to changes in the viscoelastic properties of the films that occur during phase transitions between the isoelectric form and the cationic polymer (1-NMe2H+) present at low pH or the anionic polymer (1-CO2-) present at high pH. These phase transitions are accompanied by dramatic changes in acoustic energy attenuation, film thickness changes, and film surface energy, as indicated by acoustic impedance analysis, phase measurement interferometric microscopy, and contact angle measurements. The results are consistent with pH-dependent segregation of the isolectric and ionic phases within the bulk and between the bulk and the surface. The unique pH-sensing capabilities of the coated resonators, combined with their robustness, ease of fabrication, and low cost, provide a convenient approach for the measurement of ''threshold'' pH changes. Real-time measurements of enzymatic activity and microbe metabolism are demonstrated as examples of potential applications of these sensors.
引用
收藏
页码:2553 / 2562
页数:10
相关论文
共 50 条
  • [11] Resonators using a Lamb wave on AT-cut quartz
    Nakagawa, Yasuhiko
    Momose, Masayuki
    Kakio, Shoji
    JAPANESE JOURNAL OF APPLIED PHYSICS PART 1-REGULAR PAPERS BRIEF COMMUNICATIONS & REVIEW PAPERS, 2007, 46 (7B): : 4665 - 4668
  • [12] The piezoelectrically forced vibrations of AT-cut quartz strip resonators
    Wang, J
    Momosaki, E
    PROCEEDINGS OF THE 1996 IEEE INTERNATIONAL FREQUENCY CONTROL SYMPOSIUM (50TH ANNIVERSARY), 1996, : 390 - 397
  • [13] EQUIVALENT RESONANCE RADIUS OF CONTOURED AT-CUT QUARTZ RESONATORS
    SLAVOV, SH
    APPLIED PHYSICS A-MATERIALS SCIENCE & PROCESSING, 1987, 43 (02): : 111 - 116
  • [14] AT-cut quartz resonators with inverted-mesa electrodes
    Hirama, K
    Aoyama, Y
    Naito, M
    JAPANESE JOURNAL OF APPLIED PHYSICS PART 1-REGULAR PAPERS SHORT NOTES & REVIEW PAPERS, 1997, 36 (10): : 6432 - 6436
  • [16] The piezoelectrically forced vibrations of AT-cut quartz strip resonators
    Wang, J
    Momosaki, E
    JOURNAL OF APPLIED PHYSICS, 1997, 81 (04) : 1868 - 1876
  • [17] Stress Sensitivity of Micromachined AT-cut Quartz Resonators Characterized using Magnetostrictive Metglas Films
    Goel, Nishit
    Tadigadapa, Srinivas
    2018 IEEE SENSORS, 2018, : 1644 - 1647
  • [18] Quadric analysis for AT-cut quartz resonator humidity sensors
    Nakazawa, M
    Kuroiwa, M
    Shimamoto, Y
    Iwahashi, H
    Wakamoto, S
    PROCEEDINGS OF THE 2000 IEEE/EIA INTERNATIONAL FREQUENCY CONTROL SYMPOSIUM & EXHIBITION, 2000, : 124 - 127
  • [19] Modeling quality factor in AT-cut quartz-crystal resonators
    Silva, Leonardo B. M.
    Santos, Edval J. P.
    2013 28TH SYMPOSIUM ON MICROELECTRONICS TECHNOLOGY AND DEVICES (SBMICRO 2013), 2013,
  • [20] EQUIVALENT RESONANCE RADIUS OF CONTOURED AT-CUT QUARTZ RESONATORS.
    Slavov, S.H.
    Applied Physics A: Solids and Surfaces, 1987, A43 (02): : 111 - 116