VOLTAMMETRIC STUDY OF THE REDOX BEHAVIOR OF THE HG(II)/HG(I)/HG SYSTEM AT A ROTATING METAL-RING GLASSY-CARBON DISK ELECTRODE

被引:8
|
作者
KIEKENS, P
TEMMERMAN, E
VERBEEK, F
机构
关键词
D O I
10.1016/0039-9140(84)80152-6
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
引用
收藏
页码:693 / 701
页数:9
相关论文
共 50 条
  • [21] Voltammetric Detection of Hg(II) in Real Wastewater Using Red Alga Modified Carbon Paste Electrode: Mechanism Insight
    Maria Zaib
    Muhammad Makshoof Athar
    Arabian Journal for Science and Engineering, 2019, 44 : 179 - 187
  • [22] REACTION-KINETICS OF HYDROGEN-PEROXIDE ON THE GLASSY-CARBON ROTATING-RING-DISK ELECTRODE IN ALKALINE-SOLUTION
    TANABE, H
    FUKUSHIMA, S
    NIPPON KAGAKU KAISHI, 1986, (06) : 745 - 750
  • [23] A KINETIC-STUDY OF THE CU(II)-CU(I) SYSTEM IN CL- MEDIA AT THE GLASSY-CARBON ELECTRODE
    KIEKENS, P
    VERBEECK, RMH
    TEMMERMAN, E
    MIKROCHIMICA ACTA, 1981, 2 (1-2) : 29 - 36
  • [24] GENERATION OF CHLORINE AT GLASSY-CARBON - STUDY OF KINETIC-PARAMETERS AND CURRENT EFFICIENCIES BY ROTATING-DISK ELECTRODE VOLTAMMETRY
    BISHOP, E
    COFRE, P
    ANALYST, 1981, 106 (1261) : 433 - 438
  • [25] ROTATING-DISK ELECTRODE STUDY OF THE CURRENT EFFICIENCY OF ELECTROGENERATION OF HYDROQUINONE AS COULOMETRIC TITRANT AT PLATINUM AND GLASSY-CARBON ELECTRODES
    BUTAKOVA, NA
    OGANESYAN, LB
    SOVIET ELECTROCHEMISTRY, 1985, 21 (11): : 1449 - 1454
  • [26] Improving the Voltammetric Determination of Hg(II): A Comparison Between Ligand-Modified Glassy Carbon and Electrochemically Reduced Graphene Oxide Electrodes
    Raicopol, Matei D.
    Pandele, Andreea M.
    Dascalu, Constanta
    Vasile, Eugeniu
    Hanganu, Anamaria
    Vasile, Gabriela-Geanina
    Bugean, Ioana Georgiana
    Pirvu, Cristian
    Stanciu, Gabriela
    Buica, George-Octavian
    SENSORS, 2020, 20 (23) : 1 - 18
  • [27] VOLTAMMETRIC BEHAVIOR OF THE COPPER(II) THIOUREA SYSTEM IN SULFURIC-ACID MEDIUM AT PLATINUM AND GLASSY-CARBON ELECTRODES
    COFRE, P
    BUSTOS, A
    JOURNAL OF APPLIED ELECTROCHEMISTRY, 1994, 24 (06) : 564 - 568
  • [28] Polythiophene-based MWCNTCOOH@RGO nanocomposites as a modified glassy carbon electrode for the electrochemical detection of Hg(II) ions
    AL-Refai, Hanaa H.
    Ganash, Aisha A.
    Hussein, Mahmoud A.
    CHEMICAL PAPERS, 2022, 76 (02) : 797 - 812
  • [29] Polythiophene-based MWCNTCOOH@RGO nanocomposites as a modified glassy carbon electrode for the electrochemical detection of Hg(II) ions
    Hanaa H. AL-Refai
    Aisha A. Ganash
    Mahmoud A. Hussein
    Chemical Papers, 2022, 76 : 797 - 812
  • [30] Single and simultaneous voltammetric sensing of lead(II), cadmium(II) and zinc(II) using a bimetallic Hg-Bi supported on poly(1,2-diaminoanthraquinone)/glassy carbon modified electrode
    Hassan, Khalid Mahmoud
    Gaber, Seleem Elsaid
    Altahan, Mahmoud Fatehy
    Azzem, Magdi Abdel
    SENSING AND BIO-SENSING RESEARCH, 2020, 29