IMPROVED TRANSJUGULAR INTRAHEPATIC PORTOSYSTEMIC SHUNT PATENCY WITH PTFE-COVERED STENT-GRAFTS - EXPERIMENTAL RESULTS IN SWINE

被引:114
|
作者
NISHIMINE, K
SAXON, RR
KICHIKAWA, K
MENDELHARTVIG, J
TIMMERMANS, HA
SHIM, HJ
UCHIDA, BT
BARTON, RE
KELLER, FS
ROSCH, J
机构
[1] OREGON HLTH SCI UNIV,SOTTER INTERVENT INST,PORTLAND,OR 97201
[2] NARA MED UNIV,DEPT RADIOL,NARA,JAPAN
[3] NARA MED UNIV,DEPT ONCORADIOL,NARA,JAPAN
[4] CHUNG ANG UNIV,DEPT RADIOL,SEOUL 156756,SOUTH KOREA
关键词
LIVER; INTERVENTIONAL PROCEDURE; SHUNTS; PORTOSYSTEMIC; STENTS AND PROSTHESES;
D O I
10.1148/radiology.196.2.7617843
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PURPOSE: To evaluate the ability of stent-grafts made with polytetrafluoroethylene (PTFE) graft material to improve transjugular intrahepatic portosystemic shunt (TIPS) patency. MATERIALS AND METHODS: TIPS were created in 13 swine by using PTFE-covered stent-grafts. Uncovered TIPS were placed in 13 other swine. Twenty-one of 26 animals were followed up with portal venography for 3 months or until the shunt became severely stenotic. Five animals without severe stenosis were sacrificed before 3 months because of illness. RESULTS: At 4 weeks after TIPS placement, nine of 13 stent-graft TIPS were patent (<50% diameter narrowing) compared with only one patent stent in 13 uncovered TIPS. Six of 13 stent-graft TIPS remained patent until the animals were sacrificed. In 11 of 12 uncovered TIPS, stenosis was most prominent in the parenchymal tract. In five of seven stent-graft TIPS, stenosis was most prominent in the hepatic vein above the end of the graft material. Bile leaks were discovered in six occluded uncovered TIPS and in two of the stent-graft TIPS. CONCLUSION: PTFE-covered stent-grafts significantly improved TIPS patency in swine (P < .01). However, stenosis in the hepatic vein led to late shunt malfunction in selected cases.
引用
收藏
页码:341 / 347
页数:7
相关论文
共 50 条
  • [11] PTFE-covered stent-grafts for TIPS procedure: One-year patency and clinical results
    Angeloni, S
    Nicolini, G
    Nicolao, E
    Ridola, L
    Salvatori, F
    Fanelli, F
    Rossi, P
    Attili, AF
    Merli, M
    Riggio, O
    JOURNAL OF HEPATOLOGY, 2005, 42 : 75 - 76
  • [12] PTFE-covered stent-grafts for TIPS procedure: One-year patency and clinical results
    Nicolini, G
    Angeloni, S
    Salvatori, F
    Plinio, R
    Fanelli, F
    Pepino, D
    Merli, M
    Riggio, O
    JOURNAL OF HEPATOLOGY, 2003, 38 : 66 - 66
  • [13] Transjugular Intrahepatic Portosystemic Shunt: The Covered Stent
    Patel, T.
    Funaki, B.
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2010, 194 (05)
  • [14] PTFE-covered stent-grafts for tips procedure:: One-year patency and clinical results.
    Riggio, O
    Angeloni, S
    Nicolao, F
    Nicolini, G
    Ridola, L
    Attili, AF
    Salvatori, FM
    Rossi, P
    Fanelli, F
    Merli, M
    HEPATOLOGY, 2004, 40 (04) : 630A - 630A
  • [15] Transjugular intrahepatic portosystemic shunt with an autologous vein-covered stent: Results in a swine model
    Zhuang, ZW
    Hoopes, PJ
    Koutras, PC
    Ebbighausen, WH
    Wagner, RJ
    Bettmann, MA
    JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 2001, 12 (11) : 1333 - 1342
  • [16] Dacron-covered Stent-grafts in transjugular intrahepatic portosystemic shunts: Initial experience
    Lau, CT
    Scott, M
    Stavropoulos, SW
    Soulen, MC
    Solomon, JA
    Clark, TWI
    RADIOLOGY, 2005, 236 (02) : 725 - 729
  • [17] Influence of the Secondary Deployment of Expanded Polytetrafluoroethylene-covered Stent Grafts on Maintenance of Transjugular Intrahepatic Portosystemic Shunt Patency
    Jirkovsky, Vaclav
    Fejfar, Tomas
    Safka, Vaclav
    Hulek, Petr
    Krajina, Antonin
    Chovanec, Vendelin
    Raupach, Jan
    Lojik, Miroslav
    Vanasek, Tomas
    Renc, Ondrej
    Ali, Shahzad M.
    JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 2011, 22 (01) : 55 - 60
  • [18] Expanded polytetrafluoroethylene-covered stent-grafts for transjugular intrahepatic portosystemic shunts in cirrhotic patients: Long-term patency and clinical outcome results
    Geeroms, Barbara
    Laleman, Wim
    Laenen, Annouschka
    Heye, Sam
    Verslype, Chris
    van der Merwe, Schalk
    Nevens, Frederik
    Maleux, Geert
    EUROPEAN RADIOLOGY, 2017, 27 (05) : 1795 - 1803
  • [19] Expanded polytetrafluoroethylene-covered stent-grafts for transjugular intrahepatic portosystemic shunts in cirrhotic patients: Long-term patency and clinical outcome results
    Barbara Geeroms
    Wim Laleman
    Annouschka Laenen
    Sam Heye
    Chris Verslype
    Schalk van der Merwe
    Frederik Nevens
    Geert Maleux
    European Radiology, 2017, 27 : 1795 - 1803
  • [20] Long-Term Patency and Clinical Analysis of Expanded Polytetrafluoroethylene-Covered Transjugular Intrahepatic Portosystemic Shunt Stent Grafts
    Weber, Charles N.
    Nadolski, Gregory J.
    White, Sarah B.
    Clark, Timothy W. I.
    Mondschein, Jeffrey I.
    Stavropoulos, S. William
    Shlansky-Goldberg, Richard D.
    Trerotola, Scott O.
    Soulen, Michael C.
    JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 2015, 26 (09) : 1257 - 1265