DNA FLOW-CYTOMETRY OF FRESH AND PARAFFIN-EMBEDDED TISSUE USING CYTOKERATIN STAINING

被引:0
|
作者
FREI, JV
MARTINEZ, VJ
机构
关键词
DNA FLOW CYTOMETRY; CYTOKERATIN PARAMETER; PARAFFIN SAMPLES; QUALITY CONTROL; STANDARDIZATION; COLON; BREAST; ADENOCARCINOMA;
D O I
暂无
中图分类号
R36 [病理学];
学科分类号
100104 ;
摘要
DNA flow cytometry measurements were performed using cytokeratin as a second parameter to identify epithelial cells selectively in fresh and in archival paraffin samples of normal and adenocarcinoma tissues from breast and colon. Fresh specimens consisted of 22 adenocarcinomas of breast, 20 adenocarcinomas of colon, 16 control breast samples, and 13 control colon samples. Paraffin block specimens consisted of 22 adenocarcinomas of breast (the same as fresh samples), 20 adenocarcinomas of colon (the same as fresh samples), 37 control breast samples and 34 control colon samples. The average proportion of cytokeratin-positive cells per group ranged from 31 to 55% for fresh samples and from 14 to 34% for paraffin samples. For aneuploid cells populations of adenocarcinomas, which consist only of epithelial cells, the average percentage of cytokeratin-positive cells ranged from 60 to 72%. The technique gave satisfactory measurements of ploidy and of cell cycle data in both types of samples. Cell cycle measurements were less accurate than ploidy measurements in both types of samples, and multiple sampling will be required for adequate accuracy. The average S-phase fraction of cytokeratin-positive cells ranged from 6 to 15% for fresh specimens and from 11 to 20% for paraffin samples. Similar data were obtained for the proliferative index (G1 + S + G2 + M phases). The coefficients of variation were smaller for proliferative index than for S-phase fraction data, indicating greater accuracy. Paraffin data give higher cycling cell measurements than corresponding fresh data, so separate standardization of measurements may be required for fresh and for paraffin data.
引用
收藏
页码:599 / 605
页数:7
相关论文
共 50 条
  • [41] APPLICATION OF DNA FLOW-CYTOMETRY TO PARAFFIN-EMBEDDED ARCHIVAL MATERIAL FOR THE STUDY OF ANEUPLOIDY AND ITS CLINICAL-SIGNIFICANCE
    HEDLEY, DW
    FRIEDLANDER, ML
    TAYLOR, IW
    CYTOMETRY, 1985, 6 (04): : 327 - 333
  • [42] DNA CONTENT IN FRESH VERSUS PARAFFIN-EMBEDDED TISSUE - FLOW CYTOMETRIC ANALYSIS OF 100 TUMORS
    KRAUSE, JR
    BLANK, MK
    ANALYTICAL AND QUANTITATIVE CYTOLOGY AND HISTOLOGY, 1992, 14 (02): : 89 - 95
  • [43] DNA PLOIDY OF MALIGNANT-MELANOMA DETERMINED BY IMAGE CYTOMETRY OF FRESH-FROZEN AND PARAFFIN-EMBEDDED TISSUE
    HERZBERG, AJ
    KERNS, BJ
    BOROWITZ, MJ
    SEIGLER, HF
    KINNEY, RB
    JOURNAL OF CUTANEOUS PATHOLOGY, 1991, 18 (06) : 440 - 448
  • [44] DNA FLOW-CYTOMETRY IN METASTASES AND A RECURRENCY OF MALIGNANT MELANOMAS - A COMPARISON OF RESULTS FROM FRESH AND PARAFFIN EMBEDDED MATERIAL
    JACOBSEN, AB
    THORUD, E
    FOSSA, SD
    LUNDE, S
    SHOAIB, MC
    JUUL, NO
    PETTERSEN, EO
    VIRCHOWS ARCHIV B-CELL PATHOLOGY INCLUDING MOLECULAR PATHOLOGY, 1988, 54 (05) : 273 - 277
  • [45] DNA FLOW-CYTOMETRY OF CELLS OBTAINED FROM OLD PARAFFIN-EMBEDDED SPECIMENS - A COMPARISON WITH RESULTS OF SCANNING ABSORPTION CYTOMETRY (A METHODOLOGICAL STUDY)
    FOSSA, SD
    THORUD, E
    SHOAIB, MC
    PETTERSEN, EO
    PATHOLOGY RESEARCH AND PRACTICE, 1986, 181 (02) : 200 - 205
  • [46] Interphase cytogenetic analysis of myxoid soft tissue tumors by fluorescence in situ hybridization and DNA flow cytometry using paraffin-embedded tissue
    Aoki, T
    Hisaoka, M
    Kouho, H
    Hashimoto, H
    Nakata, H
    CANCER, 1997, 79 (02) : 284 - 293
  • [47] COMPARISON OF FLOW AND IMAGE CYTOMETRY FOR DNA CONTENT-ANALYSIS OF FRESH AND FORMALIN-FIXED, PARAFFIN-EMBEDDED TISSUE IN BREAST-CARCINOMA
    CHEN, TL
    LUO, I
    MIKHAIL, N
    RASKOVA, J
    RASKA, K
    CYTOMETRY, 1995, 22 (03): : 181 - 189
  • [48] COMPARISON OF FLOW CYTOMETRIC DATA OBTAINED USING FRESH AND PARAFFIN-EMBEDDED LYMPHOID-TISSUE
    GRACE, J
    HALL, B
    ANALYTICAL AND QUANTITATIVE CYTOLOGY AND HISTOLOGY, 1989, 11 (01): : 67 - 71
  • [49] COMPARATIVE-STUDY OF DNA FLOW-CYTOMETRY ON FIXED EMBEDDED AND FRESH TISSUE FROM HUMAN LYMPHOMAS
    CAMPLEJOHN, R
    MACARTNEY, JC
    JOURNAL OF PATHOLOGY, 1985, 145 (01): : A91 - A91
  • [50] Method to make paraffin-embedded breast and lymph tissue mimic fresh tissue in DNA analysis
    Overton, WR
    Catalano, E
    McCoy, JP
    CYTOMETRY, 1996, 26 (02): : 166 - 171