POINT SPREAD FUNCTION OF THE GENERAL CONE-BEAM X-RAY RECONSTRUCTION FORMULA

被引:13
|
作者
WANG, G
LIN, TH
CHENG, PC
SHINOZAKI, DM
机构
[1] SUNY BUFFALO,DEPT ELECT & COMP ENGN,ADV REAL TIME SYST LAB,BUFFALO,NY 14260
[2] UNIV WESTERN ONTARIO,FAC ENGN SCI,DEPT MAT ENGN,LONDON N6A 3K7,ONTARIO,CANADA
关键词
D O I
10.1002/sca.4950140402
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
In this paper, the spatially varying point spread function (PSF) of the general cone-beam x-ray reconstruction formula is derived. It is proved that the vertical integral of the PSF is a two-dimensional delta-function. Therefore, although the general cone-beam formula is not exact in nature, the vertical integral of the reconstructed three-dimensional image is equal to that of the actual image. The band-limited version of the PSF is also derived. The PSF of the general cone-beam formula is simulated, based on which the reconstruction resolution can be approximately inferred.
引用
收藏
页码:187 / 193
页数:7
相关论文
共 50 条
  • [1] HALF-SCAN CONE-BEAM X-RAY MICROTOMOGRAPHY FORMULA
    WANG, G
    LIU, Y
    LIN, TH
    CHENG, PC
    SCANNING, 1994, 16 (04) : 216 - 220
  • [2] Supergridded cone-beam reconstruction and its application to point-spread function calculation
    Chen, ZK
    Ning, R
    APPLIED OPTICS, 2005, 44 (22) : 4615 - 4624
  • [3] FPGA-acceleration of cone-beam reconstruction for the X-ray CT
    Stsepankou, D
    Kornmesser, K
    Hesser, J
    Männer, R
    2004 IEEE INTERNATIONAL CONFERENCE ON FIELD-PROGRAMMABLE TECHNOLOGY, PROCEEDINGS, 2004, : 327 - 330
  • [4] An accelerated RAMLA reconstruction algorithm for X-ray cone-beam CT
    Zhao, Xing
    Hu, Jing-jing
    Yang, Tao
    Wang, Feng
    INSIGHT, 2013, 55 (05) : 237 - 242
  • [5] Anisotropic point spread function of cone-beam computed tomography
    Chen, Zikuan
    Ning, Ruola
    MEDICAL IMAGING 2007: PHYSICS OF MEDICAL IMAGING, PTS 1-3, 2007, 6510
  • [6] Coherent Cone-Beam X-ray Microscopy
    Harder, R.
    Xiao, X.
    10TH INTERNATIONAL CONFERENCE ON X-RAY MICROSCOPY, 2011, 1365 : 429 - 432
  • [7] Cone-beam reconstruction (CBR) using a X-ray simulator in intracavitary brachytherapy
    Chang, J.
    Suh, T.
    Ji, Y.
    MEDICAL PHYSICS, 2006, 33 (06) : 2083 - 2083
  • [9] AN INVERSION-FORMULA FOR CONE-BEAM RECONSTRUCTION
    TUY, HK
    SIAM JOURNAL ON APPLIED MATHEMATICS, 1983, 43 (03) : 546 - 552
  • [10] Point spread function modeling and image restoration for cone-beam CT
    张华
    黄魁东
    史仪凯
    徐哲
    Chinese Physics C, 2015, 39 (03) : 101 - 106