OPEN-LOOP POSITION CONTROL OF THE KNEE-JOINT USING ELECTRICAL-STIMULATION OF THE QUADRICEPS AND HAMSTRINGS

被引:53
|
作者
HAUSDORFF, JM [1 ]
DURFEE, WK [1 ]
机构
[1] MIT,DEPT MECH ENGN,ROOM 3-455,77 MASSACHUSETTS AVE,CAMBRIDGE,MA 02139
关键词
FUNCTIONAL ELECTRICAL STIMULATION; PARAPLEGIC GAIT;
D O I
10.1007/BF02446709
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
The clinical acceptability of functional electrical stimulation (FES) as an aid for restoration of paraplegic gait is limited by the inability to accurately and repeatedly position the lower extremity. To gain insight into the causes of and possible solutions to this problem, the responses of the quadriceps and hamstrings to FES were studied in able-bodied subjects. Isometric torque was dependent on knee angle and changed unpredictably with time. An open-loop feedforward knee-joint position controller was also tested. The results demonstrated that it is beneficial to account for the dependence of torque on position, that modifications to this open-loop controller might improve accuracy and that closed-loop control may be essential for functional restoration of gait.
引用
收藏
页码:269 / 280
页数:12
相关论文
共 50 条
  • [21] OPTIMIZING ELECTRODE PLACEMENTS AND JOINT ANGLE FOR ELECTRICAL-STIMULATION PROGRAMS AT THE KNEE
    MCNEAL, DR
    BAKER, LL
    HAMMER, D
    MARTIN, C
    MORI, K
    OBRIEN, C
    PITMAN, S
    VANDERHOEVEN, N
    PHYSICAL THERAPY, 1986, 66 (05): : 807 - 807
  • [22] Arthroscopic Evaluation of Patellofemoral Congruence With Rotation of the Knee Joint and Electrical Stimulation of the Quadriceps
    Suganuma, Jun
    Mochizuki, Ryuta
    Inoue, Yutaka
    Kitamura, Kazuya
    Honda, Akio
    ARTHROSCOPY-THE JOURNAL OF ARTHROSCOPIC AND RELATED SURGERY, 2014, 30 (02): : 214 - 221
  • [23] RECONSTRUCTION OF THE QUADRICEPS APPARATUS FOLLOWING OPEN INJURIES TO THE KNEE-JOINT USING PEDICLED GASTROCNEMIUS MUSCULOTENDINOUS UNIT AS BRIDGE GRAFT
    BABU, NV
    CHITTARANJAN, S
    ABRAHAM, G
    BHATTACHARJEE, S
    PREM, H
    KORULA, RJ
    BRITISH JOURNAL OF PLASTIC SURGERY, 1994, 47 (03): : 190 - 193
  • [24] THE EFFECT OF MECHANICAL STIMULATION OF KNEE-JOINT AFFERENTS ON QUADRICEPS MOTOR UNIT-ACTIVITY IN THE DECEREBRATE CAT
    BAXENDALE, RH
    FERRELL, WR
    WOOD, L
    BRAIN RESEARCH, 1987, 415 (02) : 353 - 356
  • [25] Closed-loop estimation of the arterial baroreflex open-loop transfer function by electrical stimulation
    Kawada, T
    Sato, T
    Sunagawa, K
    FASEB JOURNAL, 2000, 14 (04): : A386 - A386
  • [26] Closed-loop identification of carotid sinus baroreflex open-loop transfer function using electrical stimulation in rabbits
    Kawada, T
    Sato, T
    Shishido, T
    Inagaki, M
    Yanagiya, Y
    Sunagawa, K
    CIRCULATION, 1999, 100 (18) : 14 - 14
  • [27] Open-loop position tracking control of a piezoceramic flexible beam using a dynamic hysteresis compensator
    Nguyen, Phuong-Bac
    Choi, Seung-Bok
    SMART MATERIALS AND STRUCTURES, 2010, 19 (12)
  • [28] RESPONSES OF BLOOD-VESSELS IN THE RABBIT KNEE TO ELECTRICAL-STIMULATION OF THE JOINT CAPSULE
    FERRELL, WR
    KHOSHBATEN, A
    JOURNAL OF PHYSIOLOGY-LONDON, 1990, 423 : 569 - 578
  • [29] Targeting qubit states using open-loop control
    D'Helon, C
    Protopopescu, V
    Perez, R
    JOURNAL OF PHYSICS A-MATHEMATICAL AND GENERAL, 2003, 36 (25): : 7129 - 7148
  • [30] Loopshaped wavefront control using open-loop reconstructors
    Lee, Lawton H.
    OPTICS EXPRESS, 2006, 14 (17): : 7477 - 7486