Destruction of Escherichia coli and Enterococcus faecalis Using Low Frequency Ultrasound Technology: A Response Surface Methodology

被引:6
|
作者
Gholami, Mitra [1 ,2 ]
Mirzaei, Roya [1 ]
Mohammadi, Rashin [3 ]
Zarghampour, Zohre [4 ]
Afshari, Akhtar [1 ]
机构
[1] Iran Univ Med Sci, Sch Publ Hlth, Dept Environm Hlth Engn, Tehran, Iran
[2] Iran Univ Med Sci, Occupat Hlth Res Ctr, Tehran, Iran
[3] Univ Tehran, Coll Sci, Dept Cellular Mol Biol, Tehran, Iran
[4] Tehran Water & Wastewater Co, Tehran, Iran
来源
HEALTH SCOPE | 2014年 / 3卷 / 01期
关键词
Escherichia coli; Enterococcus faecalis; Sonication; Disinfection;
D O I
10.17795/jhealthscope-14213
中图分类号
R1 [预防医学、卫生学];
学科分类号
1004 ; 120402 ;
摘要
Background: Ultrasonic irradiation has been used for a variety of purposes. Ultrasound is able to inactivate bacteria and deagglomerate bacterial clusters through a number of physical, mechanical and chemical effects. Objectives: The current study aimed to investigate the effect of ultrasound technology on Escherichia coli (E. coli) (ATCC 25922) and Enterococcus faecalis (E. faecalis) (ATCC 11700) reduction in drinking water. Materials and Methods: Fifty mL inoculated samples of drinking water were sonicated by ultrasonic homogenizer with the dissipated power (Pdiss) of 70 watt and 20 KHz frequency at 2, 6 and 10 pulse/s ultrasound cycles, with the retention time of 5 and 10 minutes and also the microbial suspension concentration of 3, 6 and 9 CFU/mL. Microbial colonies were counted by McFarland and plate count methods. Response surface methodology (RSM) was applied to optimize the operating conditions. Design-Experts 8 (trial version) was employed in order to perform an ANOVA to analyze the ultrasound efficiency for the selected bacterial inactivation. Results: The results showed that E. coli and E. faecalis were effectively treated at 10 pulse/s in 9 minutes and 6 log CFU/mL bacterial suspension (P < 0.0001 for E. coli with 99.99% (4 log) and P = 0.0002 for E. faecalis with 97.5% removal efficiency). High coefficient of correlation (R-2 = 99.85 for E. coli and R-2 = 99.49 for E. faecalis) indicated that the model was reproducible. Conclusions: ANOVA results showed that the effect of cycle and time on the selected bacterial removal efficiency were more important than that of the microbial concentration.
引用
收藏
页数:9
相关论文
共 50 条
  • [41] Extracellular Production of Recombinant L-Asparaginase II in Escherichia coli: Medium Optimization Using Response Surface Methodology
    Ghoshoon, Mohammad Bagher
    Berenjian, Aydin
    Hemmati, Shiva
    Dabbagh, Fatemeh
    Karimi, Zeinab
    Negahdaripour, Manica
    Ghasemi, Younes
    INTERNATIONAL JOURNAL OF PEPTIDE RESEARCH AND THERAPEUTICS, 2015, 21 (04) : 487 - 495
  • [42] Optimization of Fermentation Process for Human-like Collagen Production of Recombinant Escherichia coli Using Response Surface Methodology
    Zhang Chi
    Fan Daidi
    Shang Long'an
    Ma Xiaoxuan
    Luo Yan'e
    Xue Wenjiao
    Gao Pengfei
    CHINESE JOURNAL OF CHEMICAL ENGINEERING, 2010, 18 (01) : 137 - 142
  • [43] Deactivating environmental strains of Escherichia coli, Enterococcus faecalis and Clostridium perfringens from a real wastewater effluent using UV-LEDs
    Kamel, A.
    Fuentes, M.
    Palacios, A. M.
    Rodrigo, M. J.
    Vivar, M.
    HELIYON, 2022, 8 (12)
  • [44] Removal of Escherichia coli and Enterococcus faecalis from synthetic wastewater using thermally treated palygorskite as a bacterial adsorbent in fixed bed reactors
    Mavrikos, Aristodimos
    Tekerlekopoulou, Athanasia. G.
    Venieri, Danae
    Lazaratou, Christina., V
    Vayenas, Dimitris
    Papoulis, Dimitris
    JOURNAL OF CHEMICAL TECHNOLOGY AND BIOTECHNOLOGY, 2024, 99 (11) : 2228 - 2236
  • [45] Efficient refolding of recombinant lipase from Escherichia coli inclusion bodies by response surface methodology
    Akbari, Neda
    Khajeh, Khosro
    Ghaemi, Nasser
    Salemi, Zahra
    PROTEIN EXPRESSION AND PURIFICATION, 2010, 70 (02) : 254 - 259
  • [46] Towards higher accuracy for ECM hybridized with low-frequency vibrations using the response surface methodology
    Ebeid, SJ
    Hewidy, MS
    El-Taweel, TA
    Youssef, AH
    JOURNAL OF MATERIALS PROCESSING TECHNOLOGY, 2004, 149 (1-3) : 432 - 438
  • [47] Reduction of Escherichia coli and Vibrio parahaemolyticus Counts on Freshly Sliced Shad (Konosirus punctatus) by Combined Treatment of Slightly Acidic Electrolyzed Water and Ultrasound Using Response Surface Methodology
    Shin Young Park
    Sang-Do Ha
    Food and Bioprocess Technology, 2015, 8 : 1762 - 1770
  • [49] Optimization of culture conditions for a synthetic gene expression in Escherichia coli using response surface methodology:: The case of human interferon beta
    Paz Maldonado, Luz M. T.
    Hernandez, Victor E. Balderas
    Rivero, Emilio Medina
    de la Rosa, Ana P. Barba
    Flores, Jose L. Flores
    Acevedo, Leandro G. Ordonez
    De Leon Rodriguez, Antonio
    BIOMOLECULAR ENGINEERING, 2007, 24 (02): : 217 - 222
  • [50] Response surface methodology for damage detection using frequency and mode shape
    Umar, Sarehati
    Bakhary, Norhisham
    Abidin, A. R. Z.
    MEASUREMENT, 2018, 115 : 258 - 268