SIMULTANEOUS DETERMINATION OF PALLADIUM AND NICKEL IN ELECTROPLATING SOLUTIONS BY DIFFERENTIAL-PULSE POLAROGRAPHY

被引:9
|
作者
BASU, BJ
RAJAGOPALAN, SR
机构
[1] Materials Science Division, National Aeronautical Laboratory
关键词
PALLADIUM DETERMINATION; NICKEL DETERMINATION; DIFFERENTIAL-PULSE POLAROGRAPHY; DIMETHYLGLYOXIME; ELECTROPLATING SOLUTION;
D O I
10.1039/an9921701623
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Differential-pulse polarography can be successfully employed for the simultaneous determination of palladium and nickel in electroplating baths. Both palladium and nickel give peaks in ammoniacal ammonium chloride and ammoniacal ammonium tartrate media that are separated by about 250 mV. When the nickel-to-palladium ratio exceeds 100, ethylenediaminetetraacetic acid (EDTA) may be added to complex nickel and thus remove the interference due to an excess of nickel. In the presence of large amounts of palladium, dimethylglyoxime is used to enhance the peak current of nickel. The palladium peak in ammoniacal ammonium chloride buffer at pH 9.0 is not affected by the presence of either EDTA or dimethylglyoxime. Hence it is possible to determine palladium and nickel simultaneously and in the presence of an excess of each other.
引用
收藏
页码:1623 / 1625
页数:3
相关论文
共 50 条
  • [21] DETERMINATION OF ASCORBIC-ACID IN ASPARAGUS BY DIFFERENTIAL-PULSE POLAROGRAPHY
    ESTEVE, MJ
    FARRE, R
    FRIGOLA, A
    FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1995, 351 (08): : 804 - 805
  • [22] DETERMINATION OF MICROGRAM AMOUNTS OF URANIUM IN THORIUM BY DIFFERENTIAL-PULSE POLAROGRAPHY
    DAS, SK
    KULKARNI, AV
    DHANESHWAR, RG
    ANALYST, 1993, 118 (09) : 1153 - 1155
  • [23] DETERMINATION OF THE STOICHEIOMETRY OF URANIUM-DIOXIDE BY DIFFERENTIAL-PULSE POLAROGRAPHY
    BULDINI, PL
    FERRI, D
    PAULUZZI, E
    ZAMBIANCHI, M
    ANALYST, 1984, 109 : 225 - 227
  • [24] DETERMINATION OF FLUOCINOLONE ACETONIDE IN PHARMACEUTICAL PREPARATIONS BY DIFFERENTIAL-PULSE POLAROGRAPHY
    LEUNG, CP
    TAM, SYK
    ANALYST, 1981, 106 (1258) : 100 - 104
  • [25] DETERMINATION OF PROPAZINE BY DIFFERENTIAL-PULSE POLAROGRAPHY IN MICELLAR AND EMULSIFIED MEDIA
    MATEOS, MA
    GALVEZ, R
    DEVILLENA, FJM
    PINGARRON, JM
    MIKROCHIMICA ACTA, 1995, 120 (1-4) : 339 - 349
  • [26] Determination of cinnamic acid in human urine by differential-pulse polarography
    Ferreira, VS
    Melios, CB
    Zanoni, MVB
    Stradiotto, NR
    ANALYST, 1996, 121 (02) : 263 - 267
  • [27] REVERSE DIFFERENTIAL-PULSE VOLTAMMETRY AND POLAROGRAPHY
    CAMACHO, L
    RUIZ, J
    SERNA, C
    MARTINEZORTIZ, F
    MOLINA, A
    ANALYTICAL CHEMISTRY, 1995, 67 (15) : 2619 - 2624
  • [28] DETERMINATION OF PYRIDINE-BASED LEVELING COMPOUNDS IN NICKEL ELECTROPLATING BATHS BY DIFFERENTIAL PULSE POLAROGRAPHY
    CARANO, M
    WARD, W
    PLATING AND SURFACE FINISHING, 1984, 71 (11): : 54 - 56
  • [29] SIMPLIFIED TREATMENT OF DIFFERENTIAL-PULSE POLAROGRAPHY
    FATOUROS, N
    KRULIC, D
    ROUELLE, F
    CHAMPAGNE, GY
    ELECTROANALYSIS, 1993, 5 (5-6) : 493 - 496
  • [30] DETERMINATION OF SACCHARIN IN ELECTROPLATING BATHS BY DIFFERENTIAL PULSE AND AC POLAROGRAPHY