Four fresh, cadaveric specimens were fitted with total knee replacements and mounted on a knee joint loading and measuring rig. Femoral component micromotion in the sagittal plane was measured with a transducer during flexion and extension of the specimen. Various condylar designs were used without and with cement. Movement followed a characteristic curve pattern and was less with cement fixation particularly for bone of low trabecular strength as determined by bone sample tests for stiffness. Cement fixation appears to be superior to cementless fixation.
引用
收藏
页码:25 / 28
页数:4
相关论文
共 50 条
  • [11] The effect of the design of the femoral component on the conformity of the patellofemoral joint in total knee replacement
    Ma, H.-M.
    Lu, Y.-C.
    Kwok, T.-G.
    Ho, F.-Y.
    Huang, C.-Y.
    Huang, C.-H.
    JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2007, 89B (03): : 408 - 412
  • [12] Theoretical assessment of an intramedullary condylar component versus screw fixation for the condylar component of a hemiarthroplasty alloplastic TMJ replacement system
    Ramos, A.
    Mesnard, M.
    Relvas, C.
    Completo, A.
    Simoes, J. A.
    JOURNAL OF CRANIO-MAXILLOFACIAL SURGERY, 2014, 42 (02) : 169 - 174
  • [13] The effect of tibial stem design on component micromotion in knee arthroplasty
    Stern, SH
    Wills, RD
    Gilbert, JL
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 1997, (345) : 44 - 52
  • [14] THE EFFECT OF SCREWS AND PEGS ON THE INITIAL FIXATION STABILITY OF AN UNCEMENTED UNICONDYLAR KNEE REPLACEMENT
    KAISER, AD
    WHITESIDE, LA
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 1990, (259) : 169 - 178
  • [15] The accuracy of sizing of the femoral component in total knee replacement
    Fu-Yuen Ng
    Xue-Feng Jiang
    Wen-Zhen Zhou
    Kwong-Yuen Chiu
    Chun-Hoi Yan
    Margaret W. M. Fok
    Knee Surgery, Sports Traumatology, Arthroscopy, 2013, 21 : 2309 - 2313
  • [16] The accuracy of sizing of the femoral component in total knee replacement
    Ng, Fu-Yuen
    Jiang, Xue-Feng
    Zhou, Wen-Zhen
    Chiu, Kwong-Yuen
    Yan, Chun-Hoi
    Fok, Margaret W. M.
    KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2013, 21 (10) : 2309 - 2313
  • [17] Determination of femoral component size in unicompartmental knee replacement
    Fawzy, Ernest
    Pandit, Hemant
    Jenkins, Cathy
    Dodd, Christopher A. F.
    Murray, David W.
    KNEE, 2008, 15 (05): : 403 - 406
  • [18] Loosening of the femoral component after unicompartmental knee replacement
    Monk, A. P.
    Keys, G. W.
    Murray, D. W.
    JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2009, 91B (03): : 405 - 407
  • [19] Is a femoral component applicator useful in total knee replacement?
    Faraj, Adnan A.
    Boda, Prashant
    KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2009, 17 (02) : 125 - 127
  • [20] Fatigue fracture of the femoral component in total knee replacement
    Chithartha, Karthik
    Thilak, Jai
    Sukesh, A. N.
    Theruvil, Bipin
    KNEE, 2020, 27 (05): : 1439 - 1445