Four fresh, cadaveric specimens were fitted with total knee replacements and mounted on a knee joint loading and measuring rig. Femoral component micromotion in the sagittal plane was measured with a transducer during flexion and extension of the specimen. Various condylar designs were used without and with cement. Movement followed a characteristic curve pattern and was less with cement fixation particularly for bone of low trabecular strength as determined by bone sample tests for stiffness. Cement fixation appears to be superior to cementless fixation.
引用
收藏
页码:25 / 28
页数:4
相关论文
共 50 条
  • [1] The influence of stem length and fixation on initial femoral component stability in revision total knee replacement
    Conlisk, N.
    Gray, H.
    Pankaj, P.
    Howie, C. R.
    BONE & JOINT RESEARCH, 2012, 1 (11): : 281 - 288
  • [2] MICROMOTION ANALYSIS OF THE FIXATION OF TOTAL KNEE TIBIAL COMPONENT
    TISSAKHT, M
    ESKANDARI, H
    AHMED, AM
    COMPUTERS & STRUCTURES, 1995, 56 (2-3) : 365 - 375
  • [3] FIXATION OF TIBIAL COMPONENTS OF CONDYLAR REPLACEMENT KNEE PROSTHESES
    WALKER, PS
    RANAWAT, C
    INSALL, J
    JOURNAL OF BIOMECHANICS, 1976, 9 (04) : 269 - &
  • [4] LOOSENING OF FEMORAL COMPONENT IN SURFACE REPLACEMENT OF KNEE
    COLLEY, J
    CAMERON, HU
    FREEMAN, MAR
    SWANSON, SAV
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 1978, 92 (01) : 31 - 34
  • [5] FRACTURE OF A UNICOMPARTMENTAL KNEE REPLACEMENT FEMORAL COMPONENT
    MORELAND, JR
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 1986, (206) : 166 - 168
  • [6] Enhancing femoral cement fixation in total knee arthroplasty
    LaButti, RS
    Bayers-Thering, M
    Krackow, KA
    JOURNAL OF ARTHROPLASTY, 2003, 18 (08): : 979 - 983
  • [7] Long-term implant-bone fixation of the femoral component in total knee replacement
    Cristofolini, L.
    Affatato, S.
    Erani, P.
    Leardini, W.
    Tigani, D.
    Viceconti, M.
    PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART H-JOURNAL OF ENGINEERING IN MEDICINE, 2008, 222 (H3) : 319 - 331
  • [8] FEMORAL COMPONENT LOOSENING USING CONTEMPORARY TECHNIQUES OF FEMORAL CEMENT FIXATION
    HARRIS, WH
    MCCARTHY, JC
    ONEILL, DA
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1982, 64 (07): : 1063 - 1067
  • [9] REPLACEMENT OF THE PATELLO-FEMORAL JOINT WITH THE TOTAL CONDYLAR KNEE ARTHROPLASTY
    RANAWAT, CS
    ROSE, HA
    BRYAN, WJ
    INTERNATIONAL ORTHOPAEDICS, 1984, 8 (01) : 61 - 65
  • [10] Custom total knee replacement in a dog with femoral condylar bone loss
    Liska, William D.
    Marcellin-Little, Denis J.
    Eskelinen, Esa V.
    Sidebotham, Christopher G.
    Harrysson, Ola L. A.
    Hielm-Bjorkman, Anna K.
    VETERINARY SURGERY, 2007, 36 (04) : 293 - 301