Clinical comparison of two initial arch wires (A-NiTi and Heat Activated NiTi) for amount of tooth alignment and perception of pain: A randomized clinical trial

被引:1
|
作者
Mahmoudzadeh, Majid [1 ]
Farhadian, Maryam [2 ]
Alijani, Sara [1 ]
Azizi, Fatemeh [3 ]
机构
[1] Hamadan Univ Med Sci, Dent Fac, Orthodont Dept, Hamadan, Iran
[2] Hamadan Univ Med Sci, Sch Publ Hlth, Dept Biostat, Biostat Modeling Noncommunicable Dis Res Ctr, Hamadan, Iran
[3] Kermanshah Univ Med Sci, Dent Fac, Orthodont Dept, Kermanshah, Iran
关键词
Orthodontic wire; Alignment; Pain;
D O I
10.1016/j.ortho.2018.01.007
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objectives: The aim of this study was to compare two initial arch wires, 0.014 '' A-NiTi and 0.016 '' Heat Activated NiTi (HANT), for amount of tooth alignment and perception of pain. Materials and methods: In total, 59 orthodontic patients (21 males and 38 females) from three orthodontic clinics participated in this 2-arm, parallel-group clinical trial and were randomized to 0.014 '' A-NiTi (n = 30) or 0.016 '' HANT groups (n = 29). Patient recruitment commenced in April 2016 and ended in December 2016. Age of the patients was between 12 to 25 years with an average of 17.92 +/- 3.74 years. Eligibility criteria included permanent dentition, non-extraction treatment plan in lower arch, Irregularity Index > 2 in lower arch, no systemic disease influencing pain, no chronic Non Steroid Anti Inflammatory Drug (NSAID) therapy, and no history of dental pain, mucosal ulcers or temporomandibular disorders (TMD). Blinding was applicable to the patients and outcome assessment. The primary outcome was to compare the reduction of the Irregularity Index mean from bonding sessions to 4 weeks later in these groups and the secondary outcome was evaluation of the pain according to the modified McGill Pain Questionnaire (MPQ) with Visual Analogue Scale questionnaire (VAS). Results: The mean differences of irregularity indices between the two groups are not statistically significant (95% CI: 0.39-1.03; P = 0.36) and according to the questionnaire, there was no significant difference between the two groups in trigger, site, description, duration, beginning, medication, and pain reduction over time. However, the VAS scale of HANT group was significantly higher than that of A-NiTi (P = 0.04). Conclusion: Results from this investigation suggested that there was no clinical difference in amount of tooth alignment and perception of pain between 0.0140 '' A-NiTi and 0.016 '' HANT wires. (C) 2018 CEO. Published by Elsevier Masson SAS. All rights reserved
引用
收藏
页码:60 / 72
页数:13
相关论文
共 43 条
  • [1] Tooth alignment and pain experience with A-NiTi versus Cu-NiTi: a randomized clinical trial
    Fatemeh Azizi
    Aida Extiari
    Mohammad Moslem Imani
    BMC Oral Health, 21
  • [2] Tooth alignment and pain experience with A-NiTi versus Cu-NiTi: a randomized clinical trial
    Azizi, Fatemeh
    Extiari, Aida
    Imani, Mohammad Moslem
    BMC ORAL HEALTH, 2021, 21 (01)
  • [3] MULTIFLEX VERSUS SUPERELASTIC - A RANDOMIZED CLINICAL-TRIAL OF THE TOOTH ALIGNMENT ABILITY OF INITIAL ARCH WIRES
    WEST, AE
    JONES, ML
    NEWCOMBE, RG
    AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 1995, 108 (05) : 464 - 471
  • [4] Alleviation of Lower Anterior Crowding with Super-Elastic and Heat-Activated NiTi Wires: A Prospective Clinical Trial
    Keerthana, Pasupureddi
    Chitra, Prasad
    TURKISH JOURNAL OF ORTHODONTICS, 2021, 34 (02) : 127 - 135
  • [6] Assessment of postoperative pain after reciprocating or rotary NiTi instrumentation of root canals: a randomized, controlled clinical trial
    Formigas Relvas, Joao Bosko
    Barreto Bastos, Mariana Mena
    Franco Marques, Andre Augusto
    Bitencourt Garrido, Angela Delfina
    Sponchiado, Emilio Carlos, Jr.
    CLINICAL ORAL INVESTIGATIONS, 2016, 20 (08) : 1987 - 1993
  • [7] Assessment of postoperative pain after reciprocating or rotary NiTi instrumentation of root canals: a randomized, controlled clinical trial
    João Bosko Formigas Relvas
    Mariana Mena Barreto Bastos
    André Augusto Franco Marques
    Angela Delfina Bitencourt Garrido
    Emílio Carlos Sponchiado
    Clinical Oral Investigations, 2016, 20 : 1987 - 1993
  • [8] Perception of discomfort during initial orthodontic tooth alignment using a self-ligating or conventional bracket system: a randomized clinical trial
    Scott, Paul
    Sherriff, Martyn
    DiBiase, Andrew T.
    Cobourne, Martyn T.
    EUROPEAN JOURNAL OF ORTHODONTICS, 2008, 30 (03) : 227 - 232
  • [9] Erratum to: Assessment of postoperative pain after reciprocating or rotary NiTi instrumentation of root canals: a randomized, controlled clinical trial
    João Bosko Formigas Relvas
    Mariana Mena Barreto Bastos
    André Augusto Franco Marques
    Angela Delfina Bitencourt Garrido
    Fernando Jose Herkrath
    Emílio Carlos Sponchiado
    Clinical Oral Investigations, 2016, 20 : 1995 - 1995
  • [10] Comparison of Pain Perception and Discomfort with Three Types of Nickel-Titanium Arch Wires during the Initial Alignment with Fixed Orthodontic Treatment in Lower Arch: An Observational Study
    Joshi, Tanu
    Bhardwaj, Amit
    Toshniwal, Nandlal G.
    Mani, Shubhangi
    Choudhary, Vaibhav Kumar
    Patel, Shalini
    JOURNAL OF THE INTERNATIONAL CLINICAL DENTAL RESEARCH ORGANIZATION, 2020, 12 (02) : 119 - 126