QUANTITATIVE DETECTION OF HEMOGLOBIN SATURATION IN THE LIVER WITH NEAR-INFRARED SPECTROSCOPY

被引:63
|
作者
KITAI, T [1 ]
TANAKA, A [1 ]
TOKUKA, A [1 ]
TANAKA, K [1 ]
YAMAOKA, Y [1 ]
OZAWA, K [1 ]
HIRAO, K [1 ]
机构
[1] OTSUKA ELECTR,SHIGA 528,JAPAN
关键词
D O I
10.1002/hep.1840180426
中图分类号
R57 [消化系及腹部疾病];
学科分类号
摘要
To quantify the changes in oxygen saturation of hemoglobin in the liver in hypoxia and liver transplantation, we applied a novel method using near-infrared spectroscopy. Instead of the conventional two-wavelength method, we obtained near-infrared data from a wide spectral range of 700 nm to 1,000 nm with continuous-wave spectroscopy. To correct the flattened spectral shape caused by photon scattering in living tissue, we then applied an equation taking into account the relationship between absorber concentration and actual absorption in scattering materials as assessed with time-resolved spectroscopy. Hepatic hemoglobin oxygen saturation was calculated with multicomponent analysis. In room air, hepatic hemoglobin oxygen saturation of rabbit was calculated as 57.4% +/- 2.5% (mean +/- S.E.M., n = 7). Arterial, portal and hepatic venous hemoglobin oxygen saturation were simultaneously measured as 97.5% +/- 0.7%, 77.1% +/- 3.4% and 55.5% +/- 4.6%, respectively. The changes in hepatic hemoglobin oxygen saturation seen in graded hypoxia were also close to those in hepatic venous hemoglobin oxygen saturation, suggesting that the average oxygenation state of sinusoidal blood approximates that in the central vein. We tested the clinical applicability of this method in a case of liver transplantation. It was determined that the hepatic hemoglobin oxygen saturation of the graft liver was heterogeneously distributed and that the initially low level of hepatic hemoglobin oxygen saturation was increased by the ligation of portal-systemic shunts.
引用
收藏
页码:926 / 936
页数:11
相关论文
共 50 条
  • [41] NEAR-INFRARED SPECTROSCOPY
    BRAZY, JE
    CLINICS IN PERINATOLOGY, 1991, 18 (03) : 519 - 534
  • [42] NEAR-INFRARED SPECTROSCOPY
    COLEMAN, D
    TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 1990, 9 (07) : 208 - 209
  • [43] NEAR-INFRARED SPECTROSCOPY
    CRUZ, J
    JOURNAL OF NEUROSURGERY, 1994, 80 (01) : 181 - 182
  • [44] MEASUREMENT OF CEREBRAL VENOUS SATURATION BY NEAR-INFRARED ABSORPTION-SPECTROSCOPY
    YOXALL, CW
    WEINDLING, AM
    DAWANI, NMH
    PEART, I
    PEDIATRIC RESEARCH, 1994, 36 (01) : A45 - A45
  • [45] NEAR-INFRARED SPECTROSCOPY
    KAWANO, S
    JOURNAL OF THE JAPANESE SOCIETY FOR FOOD SCIENCE AND TECHNOLOGY-NIPPON SHOKUHIN KAGAKU KOGAKU KAISHI, 1992, 39 (04): : 376 - 376
  • [46] NEAR-INFRARED SPECTROSCOPY
    GERMON, TJ
    YOUNG, AER
    NELSON, RJ
    JOURNAL OF NEUROSURGERY, 1995, 83 (06) : 1111 - 1111
  • [47] Vascular responsiveness determined by near-infrared spectroscopy measures of oxygen saturation
    Mclay, Kaitlin M.
    Fontana, Federico Y.
    Nederveen, Josh P.
    Guida, Federico F.
    Paterson, Donald H.
    Pogliaghi, Silvia
    Murias, Juan M.
    EXPERIMENTAL PHYSIOLOGY, 2016, 101 (01) : 34 - 40
  • [48] Development of an oxygen saturation measuring system by using near-infrared spectroscopy
    Kono, K.
    Nakamachi, E.
    Morita, Y.
    APPLIED OPTICAL METROLOGY II, 2017, 10373
  • [49] Near-infrared saturation spectroscopy of cesium molecules using a diode laser
    Chen, H
    Li, HB
    Rostovtsev, YV
    Gubin, MA
    Sautenkov, VA
    Scully, MO
    JOURNAL OF THE OPTICAL SOCIETY OF AMERICA B-OPTICAL PHYSICS, 2006, 23 (04) : 723 - 726
  • [50] MEASUREMENT OF HEMOGLOBIN FLOW AND BLOOD-FLOW BY NEAR-INFRARED SPECTROSCOPY
    EDWARDS, AD
    RICHARDSON, C
    VANDERZEE, P
    ELWELL, C
    WYATT, JS
    COPE, M
    DELPY, DT
    REYNOLDS, EOR
    JOURNAL OF APPLIED PHYSIOLOGY, 1993, 75 (04) : 1884 - 1889