THERMAL DISCOMFORT IN AIR-CONDITIONED TREATMENT ROOMS OF A PEDIATRIC INTENSIVE CAR UNIT

被引:0
|
作者
SENKPIEL, K
OHGKE, H
BECKERT, J
机构
来源
关键词
D O I
暂无
中图分类号
R1 [预防医学、卫生学];
学科分类号
1004 ; 120402 ;
摘要
Personnel of a pediatric intensive care unit claimed health problems due to air draughts. Mucous membrane symptoms such as burning eyes, an increased number of colds as well as headaches and stiff necks were the most frequent complaints. According to our indoor climate analysis high turbulence intensities were the main cause for thermal discomfort (Tu(max) = 88%, Tu(min) = 50%, median = 58% at measuring position Nr. 7). The percentage of people dissatisfied due to draught (PD value) were for example PDmax = 31%, PDmin = 6.7%, median = 16% at measuring position Nr. 7. In addition the humidification device of the HVAC system was not run continuously resulting in relative humidities below existing standards (51% r. h. in summer and 28% r. h. during the heating period).
引用
收藏
页码:319 / 329
页数:11
相关论文
共 50 条
  • [21] AIRBORNE INFECTION IN A FULLY AIR-CONDITIONED HOSPITAL .1. AIR TRANSFER BETWEEN ROOMS
    FOORD, N
    LIDWELL, OM
    JOURNAL OF HYGIENE, 1975, 75 (01) : 15 - 30
  • [22] Optimization of IAQ characteristics of an air-conditioned car using GRA and RSM
    P. Thirumal
    K. S. Amirthagadeswaran
    S. Jayabal
    Journal of Mechanical Science and Technology, 2014, 28 : 1899 - 1907
  • [23] AIR-CONDITIONED CENTER FLOW CAR MAINTAINS QUALITY OF BULK PRODUCE
    不详
    AMERICAN POTATO JOURNAL, 1969, 46 (02): : 63 - &
  • [24] Optimization of IAQ characteristics of an air-conditioned car using GRA and RSM
    Thirumal, P.
    Amirthagadeswaran, K. S.
    Jayabal, S.
    JOURNAL OF MECHANICAL SCIENCE AND TECHNOLOGY, 2014, 28 (05) : 1899 - 1907
  • [25] Investigating thermal environment inside the kitchen of air-conditioned pantry car on Indian Railway using CFD
    Alam, Md Sarfaraz
    Sharma, Milap
    Salve, Urmi R.
    HUMAN FACTORS AND ERGONOMICS IN MANUFACTURING & SERVICE INDUSTRIES, 2022, 32 (05) : 359 - 372
  • [26] Air Flow Distribution Effects on Thermal Comfort in an Air-Conditioned Enclosure
    Khalil, Essam E.
    Alhariry, Gamal
    Mahfouz, Alaa O.
    2013 ASHRAE ANNUAL CONFERENCE, 2013,
  • [27] Prediction and optimization of thermal comfort, IAQ and energy consumption of typical air-conditioned rooms based on a hybrid prediction model
    Hou, Fangli
    Ma, Jun
    Kwok, Helen H. L.
    Cheng, Jack C. P.
    BUILDING AND ENVIRONMENT, 2022, 225
  • [28] WOUND CONTAMINATION IN CONVENTIONALLY AIR-CONDITIONED OPERATING-ROOMS AS COMPARED TO LAMINAR-FLOW-OPERATING-ROOMS
    BOTZENHART, K
    HOPPENKAMPS, G
    ZENTRALBLATT FUR BAKTERIOLOGIE MIKROBIOLOGIE UND HYGIENE SERIE B-UMWELTHYGIENE KRANKENHAUSHYGIENE ARBEITSHYGIENE PRAVENTIVE MEDIZIN, 1978, 167 (1-2): : 29 - 37
  • [29] A CFD-based test method for control of indoor environment in air-conditioned rooms
    Li, Kangji
    Su, Hongye
    Chu, Jian
    PROCEEDINGS OF THE 31ST CHINESE CONTROL CONFERENCE, 2012, : 6933 - 6937
  • [30] Experimental and Numerical Model Investigations of Oxygen-Enriched Characteristics in Air-Conditioned Rooms
    Zhang, Chuanzhao
    Yang, Xiong
    Li, Ziyi
    Liu, Yingshu
    Zhao, Yu
    Wang, Haoyu
    Ma, Xiaojun
    Li, Chunwang
    Zhang, Yuanhui
    APPLIED SCIENCES-BASEL, 2021, 11 (11):