THERMAL DISCOMFORT IN AIR-CONDITIONED TREATMENT ROOMS OF A PEDIATRIC INTENSIVE CAR UNIT

被引:0
|
作者
SENKPIEL, K
OHGKE, H
BECKERT, J
机构
来源
关键词
D O I
暂无
中图分类号
R1 [预防医学、卫生学];
学科分类号
1004 ; 120402 ;
摘要
Personnel of a pediatric intensive care unit claimed health problems due to air draughts. Mucous membrane symptoms such as burning eyes, an increased number of colds as well as headaches and stiff necks were the most frequent complaints. According to our indoor climate analysis high turbulence intensities were the main cause for thermal discomfort (Tu(max) = 88%, Tu(min) = 50%, median = 58% at measuring position Nr. 7). The percentage of people dissatisfied due to draught (PD value) were for example PDmax = 31%, PDmin = 6.7%, median = 16% at measuring position Nr. 7. In addition the humidification device of the HVAC system was not run continuously resulting in relative humidities below existing standards (51% r. h. in summer and 28% r. h. during the heating period).
引用
收藏
页码:319 / 329
页数:11
相关论文
共 50 条
  • [1] Wall/roof thermal performance differences between air-conditioned and non air-conditioned rooms
    Barrios, G.
    Huelsz, G.
    Rechtman, R.
    Rojas, J.
    ENERGY AND BUILDINGS, 2011, 43 (01) : 219 - 223
  • [2] AIR MOVEMENTS IN ILLUMINATED AND AIR-CONDITIONED ROOMS
    SOLLNER, G
    LICHTTECHNIK, 1970, 22 (01): : 17 - &
  • [3] HEAT BALANCE IN AIR-CONDITIONED ROOMS
    HANSEN, E
    MADSEN, TL
    ACTA ANAESTHESIOLOGICA SCANDINAVICA, 1972, 16 (01) : 27 - &
  • [4] TEMPERATURE DISTRIBUTIONS IN AIR-CONDITIONED ROOMS
    PALLIER, JM
    YEZOU, R
    BRAU, J
    APPLIED ENERGY, 1983, 14 (01) : 49 - 64
  • [5] Thermal performance of envelope wall/roofs of intermittent air-conditioned rooms
    Barrios, G.
    Huelsz, G.
    Rojas, J.
    APPLIED THERMAL ENGINEERING, 2012, 40 : 1 - 7
  • [7] Transient Thermal Analysis of an Air-Conditioned IT Rack with a Thermal Buffering Unit
    VanGilder, James
    Tian, Wei
    Bean, John
    PROCEEDINGS OF THE NINETEENTH INTERSOCIETY CONFERENCE ON THERMAL AND THERMOMECHANICAL PHENOMENA IN ELECTRONIC SYSTEMS (ITHERM 2020), 2020, : 323 - 327
  • [8] Ventilation and Indoor Thermal Environment in Air-Conditioned Rooms with Open Windows in Winter
    Okamura, Akira
    Lee, Sihwan
    INDOOR ENVIRONMENTAL QUALITY PERFORMANCE APPROACHES (IAQ 2020), PT 1, 2021,
  • [9] MEASUREMENT OF SMALL AIR VELOCITIES IN AIR-CONDITIONED ROOMS.
    Gasser, R.
    Sulzer Technical Review, 1974, 56 (02): : 105 - 114
  • [10] Appraisal of Thermal Comfort in Non-Air-conditioned and Air-conditioned Railway Pantry Car Kitchens
    Alam, Md. Sarfaraz
    Muthiah, Arunachalam
    Salve, Urmi Ravindra
    INTERNATIONAL JOURNAL OF INTEGRATED ENGINEERING, 2020, 12 (08): : 318 - 327