AUTOMATED ALLYL CLEAVAGE FOR CONTINUOUS-FLOW SYNTHESIS OF CYCLIC AND BRANCHED PEPTIDES

被引:114
|
作者
KATES, SA
DANIELS, SB
ALBERICIO, F
机构
[1] MILLIPORE CORP,75A WIGGINS AVE,BEDFORD,MA 01730
[2] MILLIPORE CORP,DIV WATERS CHROMATOG,MILFORD,MA 01757
关键词
D O I
10.1006/abio.1993.1334
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
An automated allyl cleavage scheme on a continuous-flow peptide synthesizer was used for the preparation of "head-to-tail" cyclic peptides, branched peptides, and multiple antigenic peptides. Standard allyl removal uses a suspended palladium catalyst. This approach is not feasible on a batch and continuous-flow peptide synthesizer due to problematic delivery of the insoluble palladium catalyst. Solvent conditions were examined and optimized to solubilize the catalyst, prevent undesired Fmoc deblocking and be compatible with sensitive amino acids (Trp and Met) and with glyco- and sulfopeptides. Protocols for a continuous-flow peptide synthesizer were modified using new conditions to carry out the allyl cleavage scheme for the facile preparation of complex peptides. © 1993 Academic Press, Inc.
引用
收藏
页码:303 / 310
页数:8
相关论文
共 50 条
  • [21] Sustainable synthesis of N-methylated peptides in a continuous-flow fixed bed reactor
    Szloszar, Aliz
    Mandity, Istvan M.
    Fulop, Ferenc
    JOURNAL OF FLOW CHEMISTRY, 2018, 8 (01) : 21 - 27
  • [22] Toward a Continuous-Flow Synthesis of Boscalid®
    Glasnov, Toma N.
    Kappe, C. Oliver
    ADVANCED SYNTHESIS & CATALYSIS, 2010, 352 (17) : 3089 - 3097
  • [23] CONTINUOUS-FLOW SYNTHESIS OF PEPTIDES USING A POLYACRYLAMIDE-GEL RESIN (EXPANSIN(TM))
    MENDRE, C
    SARRADE, V
    CALAS, B
    INTERNATIONAL JOURNAL OF PEPTIDE AND PROTEIN RESEARCH, 1992, 39 (03): : 278 - 284
  • [24] Microchemical systems for continuous-flow synthesis
    Hartman, Ryan L.
    Jensen, Klavs F.
    LAB ON A CHIP, 2009, 9 (17) : 2495 - 2507
  • [25] A Continuous-Flow Process for the Synthesis of Artemisinin
    Kopetzki, Daniel
    Levesque, Francois
    Seeberger, Peter H.
    CHEMISTRY-A EUROPEAN JOURNAL, 2013, 19 (17) : 5450 - 5456
  • [26] AUTOMATED CONTINUOUS-FLOW ANALYSIS OF TOTAL PROTEIN IN URINE
    OMALLEY, AH
    PENNEY, MD
    MEDICAL LABORATORY SCIENCES, 1984, 41 (01): : 66 - 67
  • [27] RADIOIMMUNOASSAY FOR DIGOXIN WITH A FULLY AUTOMATED CONTINUOUS-FLOW SYSTEM
    GREENWOOD, H
    LANDON, J
    FORREST, GC
    CLINICAL CHEMISTRY, 1977, 23 (10) : 1868 - 1872
  • [28] TUBULAR DEBUBBLER FOR SEGMENTED CONTINUOUS-FLOW AUTOMATED ANALYZERS
    MARTIN, GB
    CHO, HK
    MEYERHOFF, ME
    ANALYTICAL CHEMISTRY, 1984, 56 (13) : 2612 - 2613
  • [29] AN IMPROVED FULLY AUTOMATED CONTINUOUS-FLOW SYSTEM FOR IMMUNOASSAYS
    ISMAIL, AAA
    WEST, PM
    GOLDIE, DJ
    POOLE, AC
    ANNALS OF CLINICAL BIOCHEMISTRY, 1981, 18 (SEP) : 287 - 294
  • [30] SERUM AMYLASE DETERMINATION - AUTOMATED CONTINUOUS-FLOW METHOD
    CAILLENS, H
    TALLET, F
    MENDYK, A
    RAICHVARG, D
    PATHOLOGIE BIOLOGIE, 1982, 30 (01): : 61 - 64