HOLD-UP TIME MEASUREMENTS FOR HIGH-SPEED GAS-CHROMATOGRAPHY

被引:7
|
作者
KLEMP, MA [1 ]
SACKS, RD [1 ]
机构
[1] UNIV MICHIGAN,DEPT CHEM,ANN ARBOR,MI 48109
关键词
D O I
10.1093/chromsci/29.12.507
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Hold-up time determination for high-speed gas chromatography is an important but difficult measurement, as hold-up times may be only a few seconds or less. We describe a technique where production of methane from thermal cracking of higher molecular weight compounds in an electrically heated cold trap inlet system can be used for an accurate and reliable measure for hold-up time. Hold-up time measurements from this technique are compared with values obtained from direct methane injections and from analysis of retention time data of a homologous series.
引用
收藏
页码:507 / 510
页数:4
相关论文
共 50 条
  • [21] FAST FLUIDIC LOGIC INJECTION AT PRESSURES UP TO 25 BAR IN HIGH-SPEED CAPILLARY GAS-CHROMATOGRAPHY
    SCHUTJES, CPM
    CRAMERS, CA
    VIDALMADJAR, C
    GUIOCHON, G
    JOURNAL OF CHROMATOGRAPHY, 1983, 279 (NOV): : 269 - 277
  • [22] Consistency of gas hold-up determinations
    Gonzalez, FR
    JOURNAL OF CHROMATOGRAPHY A, 1999, 832 (1-2) : 165 - 172
  • [23] GAS HOLD-UP IN AERATED REACTORS
    STPETROV, P
    PETKOV, AA
    PANAYOTOVA, EN
    DIMITROV, DI
    POPANGELOVA, MP
    CHEMICAL ENGINEERING JOURNAL AND THE BIOCHEMICAL ENGINEERING JOURNAL, 1979, 17 (03): : 169 - 171
  • [24] ON THE DETERMINATION OF THE HOLD-UP TIME IN REVERSED PHASE LIQUID-CHROMATOGRAPHY
    BERENDSEN, GE
    SCHOENMAKERS, PJ
    GALAN, LD
    VIGH, G
    VARGAPUCHONY, Z
    JOURNAL OF LIQUID CHROMATOGRAPHY, 1980, 3 (11): : 1669 - 1686
  • [25] High-speed gas chromatography
    Sacks, R
    Smith, H
    Nowak, M
    ANALYTICAL CHEMISTRY, 1998, 70 (01) : 29A - 37A
  • [26] THEORETICAL CALCULATION OF GAS HOLD-UP TIME IN CAPILLARY GAS-CHROMATOGRAPHY - INFLUENCE OF COLUMN, INSTRUMENT PARAMETERS AND ANALYSIS CONDITIONS AND COMPARISON OF DIFFERENT METHODS OF DEAD-TIME DETERMINATION
    CASTELLO, G
    VEZZANI, S
    MORETTI, P
    JOURNAL OF CHROMATOGRAPHY A, 1994, 677 (01) : 95 - 106
  • [27] Study on dispersed phase hold-up and gas hold-up in a stirred extraction column introduced with gas.
    Tan, Dingsheng
    Xu, Zhenliang
    Shi, Yajun
    Journal of Chemical Engineering of Chinese Universities, 1993, 7 (02) : 125 - 130
  • [28] Study on dispersed phase hold-up and gas hold-up in a stirred extraction column introduced with gas.
    Tan, Dingsheng
    Xu, Zhenliang
    Shi, Yajun
    Gao Xiao Hua Xue Gong Cheng Xue Bao/Journal of Chemical Engineering of Chinese Universities, 1993, 7 (02): : 125 - 130
  • [29] A method of calculating the second dimension hold-up time for comprehensive two-dimensional gas chromatography
    Koo, Imhoi
    Zhao, Yaping
    Zhang, Jun
    Kim, Seongho
    Zhang, Xiang
    JOURNAL OF CHROMATOGRAPHY A, 2012, 1260 : 193 - 199
  • [30] Hold-up time in gas chromatography V.: Dependence of the retention of n-alkanes on the chromatographic variables in isothermal gas chromatography
    Quintanilla-López, JE
    Lebrón-Aguilar, R
    García-Domínguez, JA
    JOURNAL OF CHROMATOGRAPHY A, 2000, 878 (01) : 125 - 135