DC AND LOW-FREQUENCY MAGNETIC MEASURING TECHNIQUES

被引:13
|
作者
FLANDERS, PJ [1 ]
GRAHAM, CD [1 ]
机构
[1] UNIV PENN,DEPT MAT SCI & ENGN,PHILADELPHIA,PA 19104
关键词
D O I
10.1088/0034-4885/56/3/002
中图分类号
O4 [物理学];
学科分类号
0702 ;
摘要
Experimental methods for the determination of basic magnetic properties (magnetization, Curie temperature, anisotropy, magnetostriction, and some related quantities) are reviewed. The discussion is limited to Dc and low-frequency methods, with emphasis on simple and inexpensive experimental equipment and on methods that permit measurements as a function of temperature. Information on the production and measurement of magnetic fields is included.
引用
收藏
页码:431 / 492
页数:62
相关论文
共 50 条
  • [31] Low-frequency magnetic noise in magnetic tunnel junctions
    Ren, C
    Liu, XY
    Schrag, BD
    Xiao, G
    PHYSICAL REVIEW B, 2004, 69 (10)
  • [32] DC GLOW DISCHARGE IN LOW-FREQUENCY ACOUSTIC FIELD
    SUBERTOV.S
    SLOVAK, P
    SEIFERT, A
    BULLETIN OF THE AMERICAN PHYSICAL SOCIETY, 1968, 13 (04): : 594 - &
  • [33] Low-Frequency Vibration Actuator Using a DC Motor
    Yem, Vibol
    Okazaki, Ryuta
    Kajimoto, Hiroyuki
    HAPTICS: PERCEPTION, DEVICES, CONTROL, AND APPLICATIONS, EUROHAPTICS 2016, PT II, 2016, 9775 : 317 - 325
  • [34] A DC AMPLIFIER FOR GSR AND LOW-FREQUENCY POTENTIAL MEASUREMENT
    Trueblood, Harold
    Grings, William
    JOURNAL OF PSYCHOLOGY, 1950, 30 (02): : 401 - 403
  • [35] Excess low-frequency flux noise in dc SQUIDs
    Huber, ME
    Cromar, MW
    Ono, RH
    IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, 1997, 7 (02) : 2882 - 2885
  • [36] LOW-FREQUENCY DC PULSED PLASMA FOR IRON NITRIDING
    BOUGDIRA, J
    HENRION, G
    FABRY, M
    REMY, M
    CUSSENOT, JR
    MATERIALS SCIENCE AND ENGINEERING A-STRUCTURAL MATERIALS PROPERTIES MICROSTRUCTURE AND PROCESSING, 1991, 139 (1-2): : 15 - 19
  • [37] Fundamental Mode Orthogonal Fluxgate Magnetometer Applicable for Measurements of DC and Low-Frequency Magnetic Fields
    Murata, Naofumi
    Karo, Hikaru
    Sasada, Ichiro
    Shimizu, Takafumi
    IEEE SENSORS JOURNAL, 2018, 18 (07) : 2705 - 2712
  • [38] Longitudinal detection of pulsed low-frequency, low-temperature nuclear magnetic resonance using a dc SQUID
    Wurm, M
    Brison, JP
    Flouquet, J
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1998, 69 (03): : 1456 - 1462
  • [39] MEASURING THE QUALITY FACTOR OF LOW-FREQUENCY QUARTZ RESONATORS
    KONSHIN, BN
    MEASUREMENT TECHNIQUES USSR, 1986, 29 (03): : 218 - 220
  • [40] A NEW PROCEDURE FOR MEASURING ANELASTICITY IN LOW-FREQUENCY RANGE
    PFANNES, HD
    ZEITSCHRIFT FUR METALLKUNDE, 1970, 61 (09): : 662 - &