MEASURING OF THE SHIELDING EFFECTIVENESS OF THE OUTER CONDUCTOR OF COAXIAL CABLES

被引:0
|
作者
DEHMEL, G
机构
关键词
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
For Measurements of the shielding effectiveness of the outer conductor of coaxial cables a simple but reliable method is to be selected. The methods found in the literature are briefly characterized and three appropriate ways, (1) the determination of the transimpedance from surface current of the shield and voltage inside the cable up to 30 MHz, (2) the "wire injection" method with coupled lines applied from 0.1 to 1000 MHz, and (3) the measurement of thc shield surface current using a high-frequency clamp-on current probe in the range between 1 and 500 MHz, have been chosen and tested.
引用
收藏
页码:167 / 173
页数:7
相关论文
共 50 条
  • [41] THE SHIELDING EFFECTIVENESS OF LONG CABLES .2. LT AND GTR
    MARTIN, AR
    EMERT, SE
    IEEE TRANSACTIONS ON ELECTROMAGNETIC COMPATIBILITY, 1980, 22 (04) : 269 - 275
  • [42] Effect of penetrative conductor coupling on shielding effectiveness of metal enclosure
    Li, Kai
    Wei, Guanghui
    Pan, Xiaodong
    Liu, Guohong
    Li, Xinfeng
    Gaodianya Jishu/High Voltage Engineering, 2014, 40 (09): : 2842 - 2848
  • [43] Influence of metal enclosure shielding effectiveness on short penetrating conductor
    Wei, Guanghui
    Li, Kai
    Pan, Xiaodong
    Li, Xinfeng
    Gaodianya Jishu/High Voltage Engineering, 2013, 39 (10): : 2344 - 2350
  • [44] Optimization of Shielding Effectiveness of Coaxial Double Braided Screens in Contact
    Colak, Bektas
    Cerezci, Osman
    Ari, Niyazi
    Helhel, Selcuk
    2016 9TH INTERNATIONAL KHARKIV SYMPOSIUM ON PHYSICS AND ENGINEERING OF MICROWAVES, MILLIMETER AND SUBMILLIMETER WAVES (MSMW), 2016,
  • [45] The Development of Novel Coaxial Tester on Electromagnetic Shielding Effectiveness Measurement
    Chen, Chaochan
    Sang, Yu
    2015 IEEE 6TH INTERNATIONAL SYMPOSIUM ON MICROWAVE, ANTENNA, PROPAGATION, AND EMC TECHNOLOGIES (MAPE), 2015, : 506 - 510
  • [46] Coaxial approximations determine EMI effectiveness of power cable shielding
    ORV Technologies, Orange, United States
    Powerconvers Intell Motion, 10 (51-55):
  • [47] Suggestion for Changes in Shielding Effectiveness Measuring Standard
    Hromadka, M.
    Kubik, Z.
    2013 4TH INTERNATIONAL YOUTH CONFERENCE ON ENERGY (IYCE), 2013,
  • [48] Measuring of shielding effectiveness in the range of higher frequencies
    Pavlik, Marek
    Kolcunova, Iraida
    Dolnik, Bystrik
    Kurimsky, Juraj
    Meszaros, Alexander
    Medved, Dusan
    Kolcun, Michal
    Zbojovsky, Jan
    PROCEEDINGS OF THE 14TH INTERNATIONAL SCIENTIFIC CONFERENCE ELECTRIC POWER ENGINEERING 2013, 2013, : 269 - 273
  • [49] MEASURING CONNECTOR SHIELDING EFFECTIVENESS DURING VIBRATION
    KNOWLES, ED
    BROSSIER, JC
    IEEE TRANSACTIONS ON ELECTROMAGNETIC COMPATIBILITY, 1974, MC16 (01) : 24 - 29
  • [50] THE ELECTROMAGNETIC-FIELD NEAR COAXIAL CABLES WITH NON-SOLID OUTER CONDUCTORS
    GRODNEV, II
    BASANSKAYA, PR
    KOROTKOV, VN
    TELECOMMUNICATIONS AND RADIO ENGINEERING, 1987, 41-2 (01) : 22 - 24