Correlation Between Humphrey Visual Field, Optical Coherence Tomography and Heidelberg Retina Tomograph Parameters in Primary Open-Angle Glaucoma, Normal-Tension Glaucoma and Ocular Hypertension

被引:0
|
作者
Ayhan, Ziya [1 ]
Arikan, Gul [1 ]
Gunenc, Uzeyir [1 ]
Cingil, Guray [1 ]
机构
[1] Dokuz Eylul Univ, Tip Fak, Geiz Hastalildan Anabilim Dali, Izmir, Turkey
关键词
Visual field; heidelberg retina tomograph; optical coherence tomography;
D O I
10.4274/tjo.41.352290
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To evaluate the correlation of Humphrey visual field (VF) parameters (MD and PSD) with Heidelberg Retina Tomograph (HRT) 3 and Stratus optical coherence tomography (OCT) parameters in patients with primary open-angle glaucoma (POAG), normal-tension glaucoma (NTG) and ocular hypertension (014T). Material and Method: Fifty-five eyes of 29 POAG patients, 32 eyes of 16 Off patients and 26 eyes of 13 NTG patients were enrolled in the study prospectively. Humphrey visual field test as well as optic nerve head and retinal nerve fiber layer (RNFL) thickness analysis with HRT 3 and Stratus OCT were performed in all patients; the measurements were repeated every 6 months. Results: The mean age of the patients was 66.4 +/- 10.0 years and the mean follow-up time was 22 +/- 2.2 months. In POAG and NTG groups, MD and PSD correlated with all analyzed parameters in HRT, except for the height variation contour (HVC). In POAG group, MD and PSD values correlated with all analyzed parameters in OCT, except for the rim area (RA). In NTG group, correlation was found between MD values and all parameters in OCT. In NTG group, PSD correlated with all parameters in OCT, except for the RNFL thickness. In Off group, no correlation was found between MD, PSD values and HRT parameters. In Off group, only RA values in OCT correlated with MD and PSD. In all groups, there was no statistically significant difference between the first and last examinations for MD and PSD values and for the mean RNFL thickness measured with OCT and HRT. Discussion: In our study, it was found that in POAG and NTG patients, there was a general correlation of Humphrey VF parameters with HRT 3 and Stratus OCT parameters.
引用
收藏
页码:143 / 150
页数:8
相关论文
共 50 条
  • [31] Comparison of optical coherence tomography angiography metrics in primary angle-closure glaucoma and normal-tension glaucoma
    Shen, Ruyue
    Wang, Yu Meng
    Cheung, Carol Y.
    Chan, Poemen P.
    Tham, Clement C.
    SCIENTIFIC REPORTS, 2021, 11 (01)
  • [32] Retinal mean transit time in patients with primary open-angle glaucoma and normal-tension glaucoma
    Bjarnhall, Gunilla
    Tomic, Lidija
    Mishima, Hiromu K.
    Tsukamoto, Hidetoshi
    Alm, Albert
    ACTA OPHTHALMOLOGICA SCANDINAVICA, 2007, 85 (01): : 67 - 72
  • [33] Peripapillary vessel density in healthy people, primary open-angle glaucoma, and normal-tension glaucoma
    Arish, Mohammad
    Momeni-Moghaddam, Hamed
    Alborzi, Moniba
    Maleki, Alireza
    Daneshvar, Ramin
    Heidari, Hamid-Reza
    EUROPEAN JOURNAL OF OPHTHALMOLOGY, 2024, 34 (01) : 161 - 167
  • [34] Optic disc topography in Malay patients with normal-tension glaucoma and primary open-angle glaucoma
    Adlina, Abdul Rahim
    Alisa-Victoria, Koh
    Shatriah, Ismail
    Liza-Sharmini, Ahmad Tajudin
    Ahmad, Mt Saad
    CLINICAL OPHTHALMOLOGY, 2014, 8 : 2533 - 2539
  • [35] Pattern electroretinogram changes in patients with primary open-angle glaucoma in correlation with visual field and optical coherence tomography changes
    Elohary, Asmaa M.
    Elbedewy, Hazem A.
    Saad, Hisham A.
    Eid, Tarek M.
    EUROPEAN JOURNAL OF OPHTHALMOLOGY, 2020, 30 (06) : 1362 - 1369
  • [36] Oxygen saturation of the retinal vessels may differ between primary open-angle glaucoma and normal-tension glaucoma
    Hirooka, Kazuyuki
    Shimazaki, Takeru
    Nakano, Yuki
    Nitta, Eri
    Ukegawa, Kaori
    Tsujikawa, Akitaka
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2017, 58 (08)
  • [37] Comparison of Optical Coherence Tomography, Heidelberg Retina Tomograph and Heidelberg Edge Perimeter for the detection of glaucoma with beginning visual field defects
    Scheuerle, Alexander Friedrich
    Seibel, Frauke J.
    Schulz, Stephan
    Auffarth, Gerd
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2014, 55 (13)
  • [38] COMPARISON OF VISUAL-FIELD DEFECTS BETWEEN NORMAL-TENSION AND PRIMARY OPEN-ANGLE GLAUCOMA IN THE LATE-STAGE OF THE DISEASE
    ARAIE, M
    HORI, J
    KOSEKI, N
    GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 1995, 233 (10) : 610 - 616
  • [39] Correlation of Visual Field With Peripapillary Vessel Density Through Optical Coherence Tomography Angiography in Normal-Tension Glaucoma
    Lin, Yun-Hsuan
    Huang, Shih-Ming
    Yeung, Ling
    Ku, Wan-Chen
    Chen, Henry Shen-Lih
    Lai, Chi-Chun
    Chuang, Lan-Hsin
    TRANSLATIONAL VISION SCIENCE & TECHNOLOGY, 2020, 9 (13): : 1 - 8
  • [40] Episcleral venous pressure in untreated primary open-angle and normal-tension glaucoma
    Selbach, JM
    Posielek, K
    Steuhl, KP
    Kremmer, S
    OPHTHALMOLOGICA, 2005, 219 (06) : 357 - 361