Electrochemical behaviour of clenbuterol at Nafion-modified carbon-paste electrodes

被引:48
|
作者
Moane, S
Rodriguez, JRB
Ordieres, AJM
Blanco, PT
Smyth, MR
机构
[1] UNIV OVIEDO,DEPT QUIM FIS & ANALIT,E-33006 OVIEDO,SPAIN
[2] DUBLIN CITY UNIV,SCH CHEM SCI,DUBLIN 9,IRELAND
关键词
carbon-paste electrodes; clenbuterol; electrochemical behaviour; Nafion-modified electrodes;
D O I
10.1016/0731-7085(95)01610-4
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A detailed study of the electrochemistry of clenbuterol at bare carbon-paste electrodes (CPEs) has been carried out. Results showed that clenbuterol undergoes an ECE process. This compound is irreversibly oxidised at high potentials, resulting in the formation of a product which demonstrates quasi-reversible electrochemical behaviour at less positive potentials. The amount of this chemical product formed is very pH-dependent. Investigations into the electrochemical behaviour of clenbuterol al Nafion-modified CPEs were also made. The use of a thin Nafion film cast over the CPE resulted in a large increase in peak current over bare electrodes. Linear accumulation occurred with time, the linear range increasing with decreasing concentration. This allowed the detection of low concentrations of clenbuterol. Diffusion proved to be the rate-controlling process of clenbuterol through the Nafion membrane.
引用
收藏
页码:57 / 63
页数:7
相关论文
共 50 条
  • [31] SURFACTANT MODIFIED CARBON-PASTE ELECTRODE .1. ELECTROCHEMICAL AND MICROSCOPIC CHARACTERIZATION
    DIGUA, K
    KAUFFMANN, JM
    DELPLANCKE, JL
    ELECTROANALYSIS, 1994, 6 (5-6) : 451 - 458
  • [32] ELECTROCHEMICAL-BEHAVIOR OF CELIPTIUM AT CARBON PASTE AND LIPID MODIFIED CARBON PASTE ELECTRODES
    ARCOS, J
    KAUFFMANN, JM
    PATRIARCHE, GJ
    SANCHEZBATANERO, P
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1990, 199 : 3 - ANYL
  • [33] ELECTROCHEMICAL DETERMINATION OF AG(I) AND CU(II) USING ACTIVATED CARBON-PASTE ELECTRODES
    RIVAS, GA
    ORTIZ, PI
    ANALYTICAL LETTERS, 1994, 27 (04) : 751 - 773
  • [34] IMPROVED RESPONSE OF CARBON-PASTE ELECTRODES FOR ELECTROCHEMICAL DETECTION IN FLOW SYSTEMS BY PRETREATMENT WITH SURFACTANTS
    ALBAHADILY, FN
    MOTTOLA, HA
    ANALYTICAL CHEMISTRY, 1987, 59 (07) : 958 - 962
  • [35] Powdered activated carbon and carbon paste electrodes: Comparison of electrochemical behaviour
    Biniak, S.
    Pakula, M.
    Darlewski, W.
    Świątkowski, A.
    Kula, P.
    Journal of Applied Electrochemistry, 2009, 39 (05): : 593 - 600
  • [36] Powdered activated carbon and carbon paste electrodes: comparison of electrochemical behaviour
    Biniak, S.
    Pakula, M.
    Darlewski, W.
    Swiatkowski, A.
    Kula, P.
    JOURNAL OF APPLIED ELECTROCHEMISTRY, 2009, 39 (05) : 593 - 600
  • [37] Powdered activated carbon and carbon paste electrodes: comparison of electrochemical behaviour
    S. Biniak
    M. Pakuła
    W. Darlewski
    A. Świątkowski
    P. Kula
    Journal of Applied Electrochemistry, 2009, 39 : 593 - 600
  • [38] APPLICATION OF MODIFIED CARBON-PASTE ELECTRODES FOR DETERMINATION OF CAPTAX AND BM-Z THIAZOLE
    MEDYANTSEVA, EP
    ULAKHOVICH, NA
    BUDNIKOV, GK
    INDUSTRIAL LABORATORY, 1994, 60 (04): : 197 - 199
  • [39] Reagentless biosensors based on Ru-complex modified carbon-paste/enzyme electrodes
    Ivanova, EV
    Sergeeva, VS
    Ryabov, AD
    Schuhmann, W
    JOURNAL OF INORGANIC BIOCHEMISTRY, 2001, 86 (01) : 276 - 276
  • [40] NITRATE DETECTION AT NAFION-MODIFIED ELECTRODES INCORPORATING YTTERBIUM AND URANYL ELECTROCATALYSTS
    UGO, P
    MORETTO, LM
    BALLARIN, B
    ELECTROANALYSIS, 1995, 7 (02) : 129 - 131