Electrochemical behaviour of clenbuterol at Nafion-modified carbon-paste electrodes

被引:48
|
作者
Moane, S
Rodriguez, JRB
Ordieres, AJM
Blanco, PT
Smyth, MR
机构
[1] UNIV OVIEDO,DEPT QUIM FIS & ANALIT,E-33006 OVIEDO,SPAIN
[2] DUBLIN CITY UNIV,SCH CHEM SCI,DUBLIN 9,IRELAND
关键词
carbon-paste electrodes; clenbuterol; electrochemical behaviour; Nafion-modified electrodes;
D O I
10.1016/0731-7085(95)01610-4
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A detailed study of the electrochemistry of clenbuterol at bare carbon-paste electrodes (CPEs) has been carried out. Results showed that clenbuterol undergoes an ECE process. This compound is irreversibly oxidised at high potentials, resulting in the formation of a product which demonstrates quasi-reversible electrochemical behaviour at less positive potentials. The amount of this chemical product formed is very pH-dependent. Investigations into the electrochemical behaviour of clenbuterol al Nafion-modified CPEs were also made. The use of a thin Nafion film cast over the CPE resulted in a large increase in peak current over bare electrodes. Linear accumulation occurred with time, the linear range increasing with decreasing concentration. This allowed the detection of low concentrations of clenbuterol. Diffusion proved to be the rate-controlling process of clenbuterol through the Nafion membrane.
引用
收藏
页码:57 / 63
页数:7
相关论文
共 50 条
  • [1] VOLTAMMETRIC STUDY OF SALBUTAMOL, FENOTEROL AND METAPROTERENOL AT UNMODIFIED AND NAFION-MODIFIED CARBON-PASTE ELECTRODES
    BOYD, D
    RODRIGUEZ, JRB
    ORDIERES, AJM
    BLANCO, PT
    SMYTH, MR
    ANALYST, 1994, 119 (09) : 1979 - 1984
  • [2] Simple electrochemical sensor for caffeine based on carbon and Nafion-modified carbon electrodes
    Carolina Torres, A.
    Barsan, Madalina M.
    Brett, Christopher M. A.
    FOOD CHEMISTRY, 2014, 149 : 215 - 220
  • [3] Electrochemical behavior of graphene modified carbon-paste electrodes and promazine detection
    Alaqad, Khaled M.
    Saleh, Tawfik
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2016, 252
  • [4] Differential-pulse voltammetric determination of clenbuterol in bovine urine using a nafion-modified carbon paste electrode
    Moane, S
    Smyth, MR
    OKeeffe, M
    ANALYST, 1996, 121 (06) : 779 - 784
  • [5] ELECTROCHEMICAL-BEHAVIOR OF MARCELLOMYCIN AT LIPID-MODIFIED CARBON-PASTE ELECTRODES
    CHASTEL, O
    KAUFFMANN, JM
    PATRIARCHE, GJ
    CHRISTIAN, GD
    TALANTA, 1990, 37 (02) : 213 - 217
  • [6] CEPHALOSPORIN ANTIBIOTICS AT CARBON-PASTE AND MODIFIED CARBON-PASTE ELECTRODES IN BOTH AQUEOUS AND BIOLOGICAL MEDIA
    ELMAALI, NA
    GHANDOUR, MA
    KAUFFMANN, JM
    BIOELECTROCHEMISTRY AND BIOENERGETICS, 1995, 38 (01): : 91 - 97
  • [7] UV-Spectrophotometry and square wave voltammetry at nafion-modified carbon-paste electrode for the determination of doxazosin in urine and formulations
    de Betoño, SF
    Garcia, AA
    Valentín, JFA
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 1999, 20 (04) : 621 - 630
  • [8] AN ELECTROCHEMICAL STUDY OF REDUCED ILMENITE CARBON-PASTE ELECTRODES
    MARINOVICH, Y
    BAILEY, S
    AVRAAMIDES, J
    JAYASEKERA, S
    JOURNAL OF APPLIED ELECTROCHEMISTRY, 1995, 25 (09) : 823 - 832
  • [10] Electrochemical behaviour of NAD+-modified carbon paste electrodes
    Saidman, SB
    INDIAN JOURNAL OF CHEMISTRY SECTION A-INORGANIC BIO-INORGANIC PHYSICAL THEORETICAL & ANALYTICAL CHEMISTRY, 2003, 42 (04): : 769 - 773