INCREASING THE LIMIT OF USABILITY OF CFRP TUBES BY BUILT-IN STRESSES

被引:2
|
作者
CUNTZE, RG [1 ]
HEIBEL, R [1 ]
机构
[1] URENCO LTD,MARLOW SL7 2NL,BUCKS,ENGLAND
关键词
5;
D O I
10.1016/0263-8223(93)90219-G
中图分类号
O3 [力学];
学科分类号
08 ; 0801 ;
摘要
The limit of usability of a CFRP structure is often determined by first ply failure (FPF) indicated by interfibre/matrix cracking. It will be shown how for certain types of CFRP structures this crack initiation threshold can be delayed. The process used here is prestraining in analogy to that Of prestressed concrete. It is a so-called thermo-mechanical after treatment, inducing advantageous compression built-in stresses, i.e. negative strains transverse to the fibres. Cylindrical tube specimens were wound, prestrained and submitted to hydraulic pressurisation or spin load testing. Acoustic emission monitoring and crack counting following sectioning confirmed an increase in crack threshold level for this specimen type from epsilon(hoop) almost-equal-to 0.8% to 1.3%, which is higher than the operational strain, normally defined as tensile failure strain e(parallel-to) of the fibre divided by the usual design factor j(u) = 1.5. Theoretical investigations were done in support of the design of the prestraining device and of the tube specimen, as well as an evaluation of experimental data.
引用
收藏
页码:251 / 264
页数:14
相关论文
共 47 条
  • [31] MEASUREMENT AND ANALYSIS OF TEMPERATURES AND HEAT FLOWS ON BOILER TUBES IN ORDER TO LIMIT STRESSES OF THERMAL ORIGIN
    MALJEAN, M
    REVUE GENERALE DE THERMIQUE, 1972, 11 (130): : 951 - &
  • [32] Experimental Study of the Flexural Performance of GFRP-Reinforced Seawater Sea Sand Concrete Beams with Built-In GFRP Tubes
    Deng, Xiaoqi
    Tang, Song
    Tang, Jinyu
    Liu, Shutong
    Yang, Shutong
    MATERIALS, 2024, 17 (13)
  • [33] TEST RESULTS AND POSSIBILITIES OF CALCULATING COOLING OF DUSTY PRODUCTS IN FLUIDIZED-BED COOLING CHANNELS WITH BUILT-IN COOLING TUBES
    BAHR, A
    GRABBERT, G
    RAMMLER, E
    CHEMISCHE TECHNIK, 1971, 23 (4-5): : 225 - &
  • [34] Increasing the Working Limit of Extruded Aluminum Tubes During Draw Bending by Introducing a Wiper Die
    Okude, Yusuke
    Sakaki, Shuji
    Yoshihara, Shoichiro
    MacDonald, Bryan J.
    MATERIALS TRANSACTIONS, 2012, 53 (05) : 875 - 878
  • [35] Hierarchical Sensing System Combining a Fiber-Optic Network and Distributed Built-in Capillary Sensors for Impact Damage Monitoring of CFRP Structures
    Banshoya, H.
    Minakuchi, S.
    Takeda, N.
    STRUCTURAL HEALTH MONITORING 2011: CONDITION-BASED MAINTENANCE AND INTELLIGENT STRUCTURES, VOL 1, 2011, : 539 - 546
  • [36] An Experimental Investigation on Flexural Behavior of Reinforced Concrete Beams Strengthened by an Intelligent CFRP Plate with Built-In Optical Fiber Bragg Grating Sensors
    Zhou, Zhi
    Wang, Zhenzhen
    JOURNAL OF SENSORS, 2018, 2018
  • [37] Seismic performance and bearing capacity calculation of cross shaped concrete columns with built-in T-shaped steel and steel tubes
    Zhao, Lidong
    Yu, Yong
    Tang, Congrong
    Zhong, Licai
    Qiu, Qirong
    PLOS ONE, 2023, 18 (11):
  • [38] Improved heat transfer and flow resistance achieved with drag reducing Cu nanofluids in the horizontal tube and built-in twisted belt tubes
    Sun, Bin
    Zhang, Zhimin
    Yang, Di
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2016, 95 : 69 - 82
  • [39] Axial compressive behaviour of SWSSC-filled stainless steel tube columns with in-built CFRP or stainless steel tubes
    Huang, Zhe
    Zheng, Kaiqi
    Wei, Yang
    Wang, Gaofei
    Zhang, Yirui
    JOURNAL OF BUILDING ENGINEERING, 2023, 72
  • [40] Fine-Grained Ultrasound Range Finding for Mobile Devices: Sensing Way Beyond the 24 kHz Limit of Built-In Microphones
    Chen, Yuchi
    Gong, Wei
    Liu, Jiangchuan
    Cui, Yong
    2017 IEEE CONFERENCE ON COMPUTER COMMUNICATIONS WORKSHOPS (INFOCOM WKSHPS), 2017, : 845 - 850