INCREASING THE LIMIT OF USABILITY OF CFRP TUBES BY BUILT-IN STRESSES

被引:2
|
作者
CUNTZE, RG [1 ]
HEIBEL, R [1 ]
机构
[1] URENCO LTD,MARLOW SL7 2NL,BUCKS,ENGLAND
关键词
5;
D O I
10.1016/0263-8223(93)90219-G
中图分类号
O3 [力学];
学科分类号
08 ; 0801 ;
摘要
The limit of usability of a CFRP structure is often determined by first ply failure (FPF) indicated by interfibre/matrix cracking. It will be shown how for certain types of CFRP structures this crack initiation threshold can be delayed. The process used here is prestraining in analogy to that Of prestressed concrete. It is a so-called thermo-mechanical after treatment, inducing advantageous compression built-in stresses, i.e. negative strains transverse to the fibres. Cylindrical tube specimens were wound, prestrained and submitted to hydraulic pressurisation or spin load testing. Acoustic emission monitoring and crack counting following sectioning confirmed an increase in crack threshold level for this specimen type from epsilon(hoop) almost-equal-to 0.8% to 1.3%, which is higher than the operational strain, normally defined as tensile failure strain e(parallel-to) of the fibre divided by the usual design factor j(u) = 1.5. Theoretical investigations were done in support of the design of the prestraining device and of the tube specimen, as well as an evaluation of experimental data.
引用
收藏
页码:251 / 264
页数:14
相关论文
共 47 条
  • [1] Usability Evaluation of iPhone Built-in Applications
    Al-Dabet, Saja
    Jusoh, Shaidah
    PROCEEDINGS OF THE 11TH INTERNATIONAL CONFERENCE ON ELECTRONICS, COMPUTERS AND ARTIFICIAL INTELLIGENCE (ECAI-2019), 2019,
  • [2] A usability study of iPhone built-in applications
    Faliagka, Evanthia
    Rigou, Maria
    Sirmakessis, Spiros
    BEHAVIOUR & INFORMATION TECHNOLOGY, 2015, 34 (08) : 799 - 808
  • [3] Motors with built-in drives increasing
    不详
    CONTROL ENGINEERING, 2000, 47 (02) : 13 - 13
  • [4] HOSPITAL ICU HAS BUILT-IN JOB STRESSES
    DUNAVANT, MK
    INTERNATIONAL JOURNAL OF OCCUPATIONAL HEALTH AND SAFETY, 1974, 43 (01): : 20 - 23
  • [5] A polymer with built-in charge for increasing the organic diode efficiency
    Zajarskiy, Dmitriy Alexandrovich
    Ruzanov, Oleg Michailovich
    Fedorkov, Dmitry Albertovich
    Petrov, Vladimir Vladimirovich
    Klimov, Boris Nikolaevich
    XV INTERNATIONAL SYMPOSIUM ON ADVANCED DISPLAY TECHNOLOGIES, 2007, 6637
  • [6] EFFECT OF BUILT-IN STRESSES ON DEFECTS OF GRAPHENE BASED GAS SENSORS
    Hu, Kai-Ming
    Bai, Kun-Chao
    Yan, Han
    Peng, Bo
    Zhang, Wen-Ming
    2019 20TH INTERNATIONAL CONFERENCE ON SOLID-STATE SENSORS, ACTUATORS AND MICROSYSTEMS & EUROSENSORS XXXIII (TRANSDUCERS & EUROSENSORS XXXIII), 2019, : 2388 - 2391
  • [7] Increasing the testability of object-oriented frameworks with built-in tests
    Jeon, T
    Lee, S
    Seung, H
    ADVANCED INTERNET SERVICES AND APPPLICATIONS, PROCEEDINGS, 2002, 2402 : 169 - 182
  • [8] Cylindrical magnetic shield made of a CFRP/amorphous magnetic tape/CFRP layered composite with built-in shaking coil
    Sasada, I.
    Kimura, T.
    Takeda, T.
    Shimada, M.
    Journal of Applied Physics, 2006, 99 (08):
  • [9] Cylindrical magnetic shield made of a CFRP/amorphous magnetic tape/CFRP layered composite with built-in shaking coil
    Sasada, I
    Kimura, T
    Takeda, T
    Shimada, M
    JOURNAL OF APPLIED PHYSICS, 2006, 99 (08)
  • [10] A study on the connection of Concrete Filled Steel Tubes (CFT) with built-in steel bars
    Qiao, Q. Y.
    Kawano, A.
    Nawa, A.
    Kutani, K.
    Shirakawa, T.
    STESSA 2009 - BEHAVIOUR OF STEEL STRUCTURES IN SEISMIC AREAS, 2009, : 319 - 324