RAPID AND SENSITIVE WHEAT-PROTEIN FRACTIONATION AND VARIETAL IDENTIFICATION BY NARROW-BORE REVERSED-PHASE HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY

被引:0
|
作者
HUEBNER, FR
BIETZ, JA
机构
关键词
D O I
暂无
中图分类号
O69 [应用化学];
学科分类号
081704 ;
摘要
For wheat varietal identification by reversed-phase high-performance liquid chromatography (RP-HPLC), gliadins are typically extracted from approximate to 50 mg of flour with 70% ethanol. Aliquots 10-15 mu l are analyzed on 15- or 25-cm x 4.6-mm (i.d.) columns at 1.0 ml/min for approximate to 1 hr. A gradient of increasing acetonitrile concentration, containing trifluoroacetic acid, is commonly used to elute proteins. However, such solvents are expensive, and present a disposal problem. Smaller RP-HPLC columns offer shorter analysis times, reduced flow rates, decreased disposal problems, and lower cost per analysis. The ability of such columns to fractionate gliadins and to differentiate cultivars was investigated. Using a 3.2-mm x 15-cm C-4 column, flow rate, sample size, analysis time, and solvent consumption were reduced by half, while preserving excellent resolution of extracted proteins. Gliadins can also be extracted from as little as 1-2 mg of flour or ground endosperm. With a 2.1-mm x 15-cm C-4 column (Vydac), further reductions of flow rates and analysis time (about one fourth that of a standard column) are possible, while maintaining excellent resolution. Under these conditions, solvent use is about one eighth that of standard RP-HPLC analyses. To further reduce analysis time and sample consumption, gradient times can be reduced to as little as one tenth that of standard columns, and separations can be done in only 9-10 min. Some resolution is sacrificed for such rapid analyses; while this is often acceptable, it may sometimes prevent differentiation of genetically similar cultivars that are otherwise identifiable. Similar RP-HPLC procedures can be used to analyze reduced subunits of glutenins. The ability to perform such rapid, high-resolution analyses of small samples, with low solvent consumption, suggests that narrow-bore RP-HPLC may become especially useful for selection and identification during wheat breeding.
引用
收藏
页码:504 / 507
页数:4
相关论文
共 50 条
  • [21] ON-LINE THERMIONIC DETECTION FOR NARROW-BORE REVERSED-PHASE LIQUID CHROMATOGRAPHY.
    Maris, Frans A.
    van Delft, Rob J.
    Frei, Roland W.
    Geerdink, Rene B.
    Brinkman, Udo A.Th.
    1634, (58):
  • [22] REVERSED-PHASE HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY OF BLEOMYCIN
    RZESZOTARSKI, WJ
    ECKELMAN, WC
    REBA, RC
    JOURNAL OF CHROMATOGRAPHY, 1976, 124 (01): : 88 - 91
  • [23] SEPARATION OF WHEAT GLIADINS BY PREPARATIVE REVERSED-PHASE HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY
    HUEBNER, FR
    BIETZ, JA
    CEREAL CHEMISTRY, 1984, 61 (05) : 449 - 454
  • [24] REVERSED-PHASE HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY OF DOXYCYCLINE
    DELEENHEER, AP
    NELIS, HJCF
    JOURNAL OF CHROMATOGRAPHY, 1977, 140 (03): : 293 - 299
  • [25] REVERSED-PHASE HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY OF DACTINOMYCIN
    SCHNEEBAUM, S
    BIES, JM
    BRIELE, HA
    JOURNAL OF CHROMATOGRAPHY-BIOMEDICAL APPLICATIONS, 1988, 427 (01): : 166 - 171
  • [26] SEPARATION OF WHEAT GLIADINS BY PREPARATIVE REVERSED-PHASE HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY
    HUEBNER, FR
    BIETZ, JA
    CEREAL CHEMISTRY, 1984, 61 (06) : 544 - 549
  • [27] INTRODUCTION TO REVERSED-PHASE HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY
    COLIN, H
    GUIOCHON, G
    JOURNAL OF CHROMATOGRAPHY, 1977, 141 (03): : 289 - 312
  • [28] REVERSED-PHASE HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY OF METALLOPORPHYRINS
    BOREHAM, CJ
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1990, 199 : 73 - GEOC
  • [29] REVERSED-PHASE HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY OF HISTONES
    CERTA, U
    VONEHRENSTEIN, G
    ANALYTICAL BIOCHEMISTRY, 1981, 118 (01) : 147 - 154
  • [30] REVERSED-PHASE HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY OF PEPTIDES
    NAKAZAWA, H
    NAGASE, M
    YAKUGAKU ZASSHI-JOURNAL OF THE PHARMACEUTICAL SOCIETY OF JAPAN, 1986, 106 (05): : 398 - 405