A COMPARISON OF TRANSCUTANEOUS, END-TIDAL AND ARTERIAL MEASUREMENTS OF CARBON-DIOXIDE DURING GENERAL-ANESTHESIA

被引:44
|
作者
REID, CW
MARTINEAU, RJ
MILLER, DR
HULL, KA
BAINES, J
SULLIVAN, PJ
机构
[1] OTTAWA GEN HOSP, DEPT ANAESTHESIA, 501 SMYTH RD, OTTAWA K1H 8L6, ONTARIO, CANADA
[2] OTTAWA GEN HOSP, DEPT BIOMED ENGN, OTTAWA K1H 8L6, ONTARIO, CANADA
[3] UNIV OTTAWA, OTTAWA K1N 6N5, ONTARIO, CANADA
来源
CANADIAN JOURNAL OF ANAESTHESIA-JOURNAL CANADIEN D ANESTHESIE | 1992年 / 39卷 / 01期
关键词
CARBON DIOXIDE; MONITORING; TENSION; ARTERIAL; CUTANEOUS; END-TIDAL; GRADIENTS; VENTILATION; CARBON DIOXIDE TENSION;
D O I
10.1007/BF03008669
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
A randomized, prospective study was performed to evaluate the accuracy of a new transcutaneous carbon dioxide (CO2) monitor (Fastrac(TM)) during general anaesthesia. Twenty-two adult patients undergoing elective surgery were subjected to three different levels of minute ventilation by varying their respiratory rates in a randomized cross-over design. Simultaneous measurements of transcutaneous CO2 (PTCCO2) and arterial CO2 (PaCO2) were obtained at three levels of minute ventilation (low, medium and high). End-tidal CO2 (PETCO2) values were also recorded from a mass spectrometer (SARA(TM)) at each time period. A total of 66 data sets with PaCO2 ranging from 28-62 mmHg were analyzed. The PTCCO2 values demonstrated a high degree of correlation with PaCO2 over the range of minute ventilation (y = 0.904x + 6.36, r = 0.92, P < 0.001). The PETCO2 measurement also demonstrated a generally good correlation with PaCO2 (y = 0.62x + 9.21, r = 0.89, and P < 0.01). However, the PETCO2-PaCO2 gradients (mean 7.0 +/- 3.1 mmHg) were greater than the PTCCO2-PaCO2 gradients (mean 2.3 +/- 2.4 mmHg) at all three levels of minute ventilation (P < 0.05). These differences were greatest when PaCO2 was in the high range (48-60 mmHg). We conclude that the new Fastrac(TM) CO2 monitor is accurate for monitoring carbon dioxide levels during general anaesthesia. The new transcutaneous devices provide an effective method for non-invasive monitoring of CO2 in situations where continuous, precise control of CO2 levels is desired.
引用
收藏
页码:31 / 36
页数:6
相关论文
共 50 条
  • [11] ARTERIAL TO END-TIDAL CARBON-DIOXIDE TENSION DIFFERENCE IN CHILDREN UNDER HALOTHANE ANESTHESIA
    VALENTIN, N
    LOMHOLT, B
    THORUP, M
    CANADIAN ANAESTHETISTS SOCIETY JOURNAL, 1982, 29 (01) : 12 - 15
  • [12] Comparison of Transcutaneous, Arterial and End-tidal Measurements of Carbon Dioxide during Laparoscopic Cholecystectomy in Patients with Chronic Obstructive Pulmonary Disease
    Ozyuvaci, E.
    Demircioglu, O.
    Toprak, N.
    Topacoglu, H.
    Sitilci, T.
    Akyol, O.
    JOURNAL OF INTERNATIONAL MEDICAL RESEARCH, 2012, 40 (05) : 1982 - 1987
  • [13] TRANSCUTANEOUS AND END-TIDAL CARBON-DIOXIDE PRESSURES SHOULD BE MEASURED DURING PEDIATRIC POLYSOMNOGRAPHY
    MORIELLI, A
    DESJARDINS, D
    BROUILETTE, RT
    AMERICAN REVIEW OF RESPIRATORY DISEASE, 1993, 148 (06): : 1599 - 1604
  • [14] Comparison of end-tidal and transcutaneous measures of carbon dioxide during general anaesthesia in severely obese adults
    Griffin, J
    Terry, BE
    Burton, RK
    Ray, TL
    Keller, BP
    Landrum, AL
    Johnson, JO
    Tobias, JD
    BRITISH JOURNAL OF ANAESTHESIA, 2003, 91 (04) : 498 - 501
  • [15] END-TIDAL CARBON-DIOXIDE AS AN INDICATOR OF ARTERIAL CARBON-DIOXIDE IN NEUROINTENSIVE CARE PATIENTS
    RUSSELL, GB
    GRAYBEAL, JM
    JOURNAL OF NEUROSURGICAL ANESTHESIOLOGY, 1992, 4 (04) : 245 - 249
  • [16] THE ARTERIAL TO END-TIDAL CARBON-DIOXIDE DIFFERENCE IN NEUROSURGICAL PATIENTS DURING CRANIOTOMY
    RUSSELL, GB
    GRAYBEAL, JM
    ANESTHESIA AND ANALGESIA, 1995, 81 (04): : 806 - 810
  • [17] End-tidal carbon dioxide does not correlate with arterial carbon dioxide in early recovery from general anesthesia
    Rudolph, F
    Hein, HAT
    Marcel, RJ
    Swygert, TH
    Lynch, K
    Ramsay, KJ
    Ramsay, MAE
    ANESTHESIA AND ANALGESIA, 1998, 86 (2S):
  • [18] END-TIDAL CARBON-DIOXIDE DOES NOT REFLECT ARTERIAL CARBON-DIOXIDE IN HEMORRHAGIC-SHOCK
    DOMSKY, MF
    PEROV, S
    ANESTHESIA AND ANALGESIA, 1993, 76 (02): : S85 - S85
  • [19] STABILITY OF ARTERIAL TO END-TIDAL CARBON-DIOXIDE GRADIENTS DURING POSTOPERATIVE CARDIORESPIRATORY SUPPORT
    RUSSELL, GB
    GRAYBEAL, JM
    STROUT, JC
    CANADIAN JOURNAL OF ANAESTHESIA-JOURNAL CANADIEN D ANESTHESIE, 1990, 37 (05): : 560 - 566
  • [20] TITRATION OF PEEP BY THE ARTERIAL MINUS END-TIDAL CARBON-DIOXIDE GRADIENT
    MURRAY, IP
    MODELL, JH
    GALLAGHER, TJ
    BANNER, MJ
    CHEST, 1984, 85 (01) : 100 - 104