摘要
In partial discharge (PD) phenomenon energy is emitted as electromagnetic emission, acoustic emission and chemical reactions as ozone formation and nitrous oxide gases. One of the continuous conditions monitoring process is done in high voltage equipments such as power transformer. This paper deals with a short review on PD detection methods regarding high-voltage equipments such as electrical detection, chemical detection, acoustic detection and optical detection. Also, new technique for PD signal monitoring in power transformer call as chromatic in the present. The chromatic approach shows the ability to quantifying information content of PD signal by chromatic parameters hue (H), saturation (S) and lightness (L), which can be related to characteristics of PD signal. The chromatic approach shows the ability to yielding new patterns, which monitoring indications of the discharges signals with high accurac and without noise.
引用
收藏
页数:3
相关论文
共 50 条
  • [41] Partial Discharge in 345-kV Power Transformer
    Chen, Mu-Kuen
    Cheng, Chao-Yuan
    Chen, Jeng-Ming
    Chang, Wen-Yeau
    2009 IEEE ELECTRICAL INSULATION CONFERENCE, 2009, : 17 - 20
  • [42] Locating partial discharge in power transformer by electrical method
    Gui, JF
    Gao, WS
    Tan, KX
    Gao, SY
    PROCEEDINGS OF THE 7TH INTERNATIONAL CONFERENCE ON PROPERTIES AND APPLICATIONS OF DIELECTRIC MATERIALS, VOLS 1-3, 2003, : 459 - 462
  • [43] Partial Discharge Signal Propagation Characteristics inside the Winding of Oil-immersed Power Transformer - Using the Three-Winding Transformer Model in Air
    Okabe, Shigemitsu
    Ueta, Genyo
    Wada, Haruhisa
    IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2011, 18 (06) : 2024 - 2031
  • [44] On-line power transformer partial discharge monitoring based on the optical fiber sensing technology
    Wang Kun
    Tong Xinglin
    Hu Jie
    Zhu Xiaolong
    FOURTH ASIA PACIFIC OPTICAL SENSORS CONFERENCE, 2013, 8924
  • [45] Site partial discharge test on large power transformer
    Ma, WP
    Hao, DZ
    Zheng, LH
    Cheng, YS
    JOINT CONFERENCE OF 96' AICDEI / 4T-JCCEID, 1996, : 405 - 408
  • [46] Acoustic Partial Discharge Signal Denoising using Power Spectral Subtraction
    Hussein, Ramy
    Shaban, Khaled Bashir
    El-Hag, Ayman H.
    2015 IEEE CONFERENCE ON ELECTRICAL INSULATION AND DIELECTRIC PHENOMENA (CEIDP), 2015, : 330 - 333
  • [47] Quantitative Analysis and Simple Monitoring for Partial Discharge from Transformer
    Kwak, Seung Soo
    Kim, Yong Sin
    2021 INTERNATIONAL CONFERENCE ON ELECTRONICS, INFORMATION, AND COMMUNICATION (ICEIC), 2021,
  • [48] Transformer partial discharge monitoring based on optical fiber sensing
    Wang K.
    Tong X.
    Zhu X.
    Photonic Sensors, 2014, 4 (02) : 137 - 141
  • [49] Partial Discharge Pulse Propagation in Power Cable and Partial Discharge Monitoring System
    Sheng, Bojie
    Zhou, Chengke
    Hepburn, Donald M.
    Dong, Xiang
    Peers, Graham
    Zhou, Wenjun
    Tang, Zeyang
    IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2014, 21 (03) : 948 - 956
  • [50] Partial discharge pulse propagation in power cable and partial discharge monitoring system
    1600, Institute of Electrical and Electronics Engineers Inc., United States (21):