Biomechanical Comparison of 2 Different Locking Plate Fixation Methods in Vancouver B1 Periprosthetic Femur Fractures

被引:17
|
作者
Pletka, Joshua D. [1 ]
Marsland, Daniel [2 ]
Belkoff, Stephen M. [2 ]
Mears, Simon C. [2 ]
Kates, Stephen L. [1 ]
机构
[1] Univ Rochester, Dept Orthopaed Surg, Rochester, NY USA
[2] Johns Hopkins Univ, Johns Hopkins Bayview Med Ctr, Int Ctr Orthopaed Adv, Dept Orthopaed Surg, Baltimore, MD 21205 USA
关键词
periprosthetic fracture; femur; locking plate; working length; fixation;
D O I
10.1177/2151458510397609
中图分类号
R592 [老年病学]; C [社会科学总论];
学科分类号
03 ; 0303 ; 100203 ;
摘要
Locking plates are commonly used to treat fractures around a well-fixed femoral component. The optimal construct should provide sufficient fixation while minimizing soft-tissue dissection. The purpose of the current study was to determine whether plate length, working length, or bone mineral density affects survival of locking plate fixation for Vancouver type B1 periprosthetic hip fractures. A transverse osteotomy was created just distal to cemented femoral prostheses in 9 pairs of cadaveric femurs. Fractures were stabilized with long (20-hole) or short (12-hole) locking plates that were secured proximally with cables and screws and distally with screws only. Specimens were then cycled 10 000 times at 2500 Nof axial force and 15 Nm of torque to simulate full weightbearing. Amotion capture system was used to record fracture displacement during cycling. Failure occurred in 5 long and 3 short plates, with no significant differences found in the number of cycles to failure. For the specimens that survived, there were no significant differences found between long and short plates for displacement or rotation observed at the fracture site. Ashorter working length was not associated with increased failure rate. Lower bone mineral density was significantly associated with failure (P =.02). We concluded that long locked plates do not appear to offer a biomechanical advantage over short locking plates in terms of fixation survival, and that bone mineral density was a better predictor of failure than was the fixation construct type.
引用
收藏
页码:51 / 55
页数:5
相关论文
共 50 条
  • [31] Comparison of different locking plate fixation methods in distal tibia fractures
    Krzysztof Piątkowski
    Piotr Piekarczyk
    Krzysztof Kwiatkowski
    Mateusz Przybycień
    Bartłomiej Chwedczuk
    International Orthopaedics, 2015, 39 : 2245 - 2251
  • [32] Outcomes of cable fixation after Vancouver type B1 periprosthetic femoral fractures
    Yenigul, Ali Erkan
    Ermutlu, Cenk
    Onder, Cem
    Atici, Teoman
    Durak, Kemal
    ULUSAL TRAVMA VE ACIL CERRAHI DERGISI-TURKISH JOURNAL OF TRAUMA & EMERGENCY SURGERY, 2023, 29 (11): : 1314 - 1319
  • [33] Comparison of different locking plate fixation methods in distal tibia fractures
    Piatkowski, Krzysztof
    Piekarczyk, Piotr
    Kwiatkowski, Krzysztof
    Przybycien, Mateusz
    Chwedczuk, Bartlomiej
    INTERNATIONAL ORTHOPAEDICS, 2015, 39 (11) : 2245 - 2251
  • [34] Surgical Fixation of Vancouver Type B1 Periprosthetic Femur Fractures: A Systematic Review (vol 28, pg 721, 2014)
    Dehghan, N.
    McKee, M. D.
    Nauth, A.
    JOURNAL OF ORTHOPAEDIC TRAUMA, 2015, 29 (04) : E177 - E177
  • [35] Reversed Contralateral LISS Plate for Vancouver B1 Periprosthetic Femoral Shaft Fractures
    Russo, Matthew
    Malekzadeh, A. Stephen
    Hampton, Chadwick
    Hymes, Robert
    Schwartzbach, Cary
    Schulman, Jeffrey
    ORTHOPEDICS, 2015, 38 (06) : E467 - E472
  • [36] Periprosthetic Vancouver type B1 and C fractures treated by locking-plate osteosynthesis Fracture union and reoperations in 60 consecutive fractures
    Froberg, Lonnie
    Troelsen, Anders
    Brix, Michael
    ACTA ORTHOPAEDICA, 2012, 83 (06) : 648 - 652
  • [37] Treatment of B1 Distal Periprosthetic Femur Fractures
    Sheridan, Gerard A.
    Sepehri, Aresh
    Stoffel, Karl
    Masri, Bassam A.
    ORTHOPEDIC CLINICS OF NORTH AMERICA, 2021, 52 (04) : 335 - 346
  • [38] Locking Compression Plate and Cerclage Band for Type B1 Periprosthetic Femoral Fractures
    Xue, Huaming
    Tu, Yihui
    Cai, Minwei
    Yang, Anli
    JOURNAL OF ARTHROPLASTY, 2011, 26 (03): : 467 - 471
  • [39] Finite element analysis of double-plate fixation using reversed locking compression-distal femoral plates for Vancouver B1 periprosthetic femoral fractures
    Takahashi, Daisuke
    Noyama, Yoshihiro
    Asano, Tsuyoshi
    Shimizu, Tomohiro
    Irie, Tohru
    Terkawi, Mohamad Alaa
    Iwasaki, Norimasa
    BMC MUSCULOSKELETAL DISORDERS, 2021, 22 (01)
  • [40] Atypical Vancouver B1 Periprosthetic Fractures: The Unsolved Problem
    Vicenti, Giovanni
    Solarino, Giuseppe
    Ottaviani, Guglielmo
    Carrozzo, Massimiliano
    Simone, Filippo
    Zavattini, Giacomo
    Zaccari, Domenico
    Buono, Claudio
    Bizzoca, Davide
    Maccagnano, Giuseppe
    Moretti, Biagio
    GERIATRIC ORTHOPAEDIC SURGERY & REHABILITATION, 2023, 14