Biomechanical Comparison of 2 Different Locking Plate Fixation Methods in Vancouver B1 Periprosthetic Femur Fractures

被引:17
|
作者
Pletka, Joshua D. [1 ]
Marsland, Daniel [2 ]
Belkoff, Stephen M. [2 ]
Mears, Simon C. [2 ]
Kates, Stephen L. [1 ]
机构
[1] Univ Rochester, Dept Orthopaed Surg, Rochester, NY USA
[2] Johns Hopkins Univ, Johns Hopkins Bayview Med Ctr, Int Ctr Orthopaed Adv, Dept Orthopaed Surg, Baltimore, MD 21205 USA
关键词
periprosthetic fracture; femur; locking plate; working length; fixation;
D O I
10.1177/2151458510397609
中图分类号
R592 [老年病学]; C [社会科学总论];
学科分类号
03 ; 0303 ; 100203 ;
摘要
Locking plates are commonly used to treat fractures around a well-fixed femoral component. The optimal construct should provide sufficient fixation while minimizing soft-tissue dissection. The purpose of the current study was to determine whether plate length, working length, or bone mineral density affects survival of locking plate fixation for Vancouver type B1 periprosthetic hip fractures. A transverse osteotomy was created just distal to cemented femoral prostheses in 9 pairs of cadaveric femurs. Fractures were stabilized with long (20-hole) or short (12-hole) locking plates that were secured proximally with cables and screws and distally with screws only. Specimens were then cycled 10 000 times at 2500 Nof axial force and 15 Nm of torque to simulate full weightbearing. Amotion capture system was used to record fracture displacement during cycling. Failure occurred in 5 long and 3 short plates, with no significant differences found in the number of cycles to failure. For the specimens that survived, there were no significant differences found between long and short plates for displacement or rotation observed at the fracture site. Ashorter working length was not associated with increased failure rate. Lower bone mineral density was significantly associated with failure (P =.02). We concluded that long locked plates do not appear to offer a biomechanical advantage over short locking plates in terms of fixation survival, and that bone mineral density was a better predictor of failure than was the fixation construct type.
引用
收藏
页码:51 / 55
页数:5
相关论文
共 50 条
  • [1] Do Transcortical Screws in a Locking Plate Construct Improve the Stiffness in the Fixation of Vancouver B1 Periprosthetic Femur Fractures? A Biomechanical Analysis of 2 Different Plating Constructs
    Lochab, Jasjit
    Carrothers, Andrew
    Wong, Edwin
    McLachlin, Stewart
    Aldebeyan, Wassim
    Jenkinson, Richard
    Whyne, Cari
    Nousiainen, Markku T.
    JOURNAL OF ORTHOPAEDIC TRAUMA, 2017, 31 (01) : 15 - 20
  • [2] Optimizing Proximal Fixation in Vancouver B1 Periprosthetic Femur Fractures
    Yevtukh, Alexander
    Taylor, Aaron
    OPERATIVE TECHNIQUES IN ORTHOPAEDICS, 2023, 33 (02)
  • [3] Locking plate fixation for Vancouver B1 periprosthetic femoral fractures: a critical analysis of 135 cases
    Graham, Simon M.
    Moazen, Mehran
    Leonidou, Andreas
    Tsiridis, Eleftherios
    JOURNAL OF ORTHOPAEDIC SCIENCE, 2013, 18 (03) : 426 - 436
  • [4] The locking attachment plate for proximal fixation of periprosthetic femur fractures—a biomechanical comparison of two techniques
    Mark Lenz
    Markus Windolf
    Thomas Mückley
    Gunther O. Hofmann
    Michael Wagner
    Robert G. Richards
    Karsten Schwieger
    Boyko Gueorguiev
    International Orthopaedics, 2012, 36 : 1915 - 1921
  • [5] Tangential Bicortical Locked Fixation Improves Stability in Vancouver B1 Periprosthetic Femur Fractures: A Biomechanical Study
    Lewis, Gregory S.
    Caroom, Cyrus T.
    Wee, Hwabok
    Jurgensmeier, Darin
    Rothermel, Shane D.
    Bramer, Michelle A.
    Reid, John Spence
    JOURNAL OF ORTHOPAEDIC TRAUMA, 2015, 29 (10) : e364 - e370
  • [6] Plate fixation in periprosthetic femur fractures Vancouver type B1-Trochanteric hook plate or subtrochanterical bicortical locking?
    Lenz, Mark
    Stoffel, Karl
    Kielstein, Heike
    Mayo, Keith
    Hofmann, Gunther O.
    Gueorguiev, Boyko
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2016, 47 (12): : 2800 - 2804
  • [7] Managing Vancouver B1 fractures by cerclage system compared to locking plate fixation - a biomechanical study
    Gordon, Katharina
    Winkler, Martin
    Hofstaedter, Thomas
    Dorn, Ulrich
    Augat, Peter
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2016, 47 : S51 - S57
  • [8] Surgical Fixation of Vancouver Type B1 Periprosthetic Femur Fractures: A Systematic Review
    Dehghan, Niloofar
    McKee, Michael D.
    Nauth, Aaron
    Ristevski, Bill
    Schemitsch, Emil H.
    JOURNAL OF ORTHOPAEDIC TRAUMA, 2014, 28 (12) : 721 - 727
  • [9] The Effect of Fixation Technique on the Stiffness of Comminuted Vancouver B1 Periprosthetic Femur Fractures
    Choi, Jung Keun
    Gardner, Thomas R.
    Yoon, Ed
    Morrison, Todd A.
    Macaulay, William B.
    Geller, Jeffrey A.
    JOURNAL OF ARTHROPLASTY, 2010, 25 (06): : 124 - 128
  • [10] The locking attachment plate for proximal fixation of periprosthetic femur fractures-a biomechanical comparison of two techniques
    Lenz, Mark
    Windolf, Markus
    Mueckley, Thomas
    Hofmann, Gunther O.
    Wagner, Michael
    Richards, Robert G.
    Schwieger, Karsten
    Gueorguiev, Boyko
    INTERNATIONAL ORTHOPAEDICS, 2012, 36 (09) : 1915 - 1921