Validation of 3D EM Reconstructions: The Phantom in the Noise

被引:16
|
作者
Heymann, J. Bernard [1 ]
机构
[1] Natl Inst Hlth, Natl Inst Arthrit & Musculoskeletal & Skin Dis, 50 South Dr, Bethesda, MD 20892 USA
来源
AIMS BIOPHYSICS | 2015年 / 2卷 / 01期
关键词
electron microscopy; 3D image processing; single particle analysis; gaussian noise; signal-to-noise ratio; structural biology; resolution;
D O I
10.3934/biophy.2015.1.21
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Validation is a necessity to trust the structures solved by electron microscopy by single particle techniques. The impressive achievements in single particle reconstruction fuel its expansion beyond a small community of image processing experts. This poses the risk of inappropriate data processing with dubious results. Nowhere is it more clearly illustrated than in the recovery of a reference density map from pure noise aligned to that map-a phantom in the noise. Appropriate use of existing validating methods such as resolution-limited alignment and the processing of independent data sets ("gold standard") avoid this pitfall. However, these methods can be undermined by biases introduced in various subtle ways. How can we test that a map is a coherent structure present in the images selected from the micrographs? In stead of viewing the phantom emerging from noise as a cautionary tale, it should be used as a defining baseline. Any map is always recoverable from noise images, provided a sufficient number of images are aligned and used in reconstruction. However, with smaller numbers of images, the expected coherence in the real particle images should yield better reconstructions than equivalent numbers of noise or background images, even without masking or imposing resolution limits as potential biases. The validation test proposed is therefore a simple alignment of a limited number of micrograph and noise images against the final reconstruction as reference, demonstrating that the micrograph images yield a better reconstruction. I examine synthetic cases to relate the resolution of a reconstruction to the alignment error as a function of the signal-to-noise ratio. I also administered the test to real cases of publicly available data. Adopting such a test can aid the microscopist in assessing the usefulness of the micrographs taken before committing to lengthy processing with questionable outcomes.
引用
收藏
页码:21 / 35
页数:15
相关论文
共 50 条
  • [31] Bilateral Filtering of 3D Point Clouds for Refined 3D Roadside Reconstructions
    Moorfield, Bradley
    Haeusler, Ralf
    Klette, Reinhard
    COMPUTER ANALYSIS OF IMAGES AND PATTERNS, CAIP 2015, PT II, 2015, 9257 : 394 - 402
  • [32] Validation of a Novel 3D Printed Contrast-Detail Phantom for Cardiac Nuclear Medicine
    Green, S.
    Grice, J.
    MEDICAL PHYSICS, 2020, 47 (06) : E562 - E562
  • [33] Validation of measurement-guided 3D VMAT dose reconstruction on a heterogeneous anthropomorphic phantom
    Opp, Daniel
    Nelms, Benjamin E.
    Zhang, Geoffrey
    Stevens, Craig
    Feygelman, Vladimir
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2013, 14 (04): : 70 - 84
  • [34] 3D dosimetric validation of ultrasound-guided radiotherapy with a dynamically deformable abdominal phantom
    Matrosic, Charles K.
    Culberson, Wesley
    Shepard, Andrew
    Jupitz, Sydney
    Bednarz, Bryan
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2021, 84 : 159 - 167
  • [35] A novel 2D/3D transformation for radiosurgery of ocular tumors: computer simulation and phantom validation
    Chen, Hairong
    Wu, Xiaodong
    Hatoum, Georges F.
    Zhao, Weizhao
    JOURNAL OF RADIATION ONCOLOGY, 2014, 3 (03) : 313 - 320
  • [36] Impedance mammograph 3D phantom studies
    Wtorek, J
    Stelter, J
    Nowakowski, A
    ELECTRICAL BIOIMPEDANCE METHODS: APPLICATIONS TO MEDICINE AND BIOTECHNOLOGY, 1999, 873 : 520 - 533
  • [37] Optimal noise reduction in 3D reconstructions of single particles using a volume-normalized filter
    Sindelar, Charles V.
    Grigorieff, Nikolaus
    JOURNAL OF STRUCTURAL BIOLOGY, 2012, 180 (01) : 26 - 38
  • [38] An Improved 3D Printed Cardiac Phantom
    Grice, Jared
    Green, Samantha
    Yuhas, Abigail
    JOURNAL OF NUCLEAR MEDICINE, 2020, 61
  • [39] Adaptive noise suppression technique for dense 3D point cloud reconstructions from monocular vision
    Diskin, Yakov
    Asari, Vijayan K.
    APPLICATIONS OF DIGITAL IMAGE PROCESSING XXXV, 2012, 8499
  • [40] 3D FEM and EM simulations for DRFs
    1600, Horizon House (43):