Evaluation of the Optilite (TM) system for the determination of immunoglobulin free light chains in serum (sFLC)

被引:0
|
作者
Infusino, Ilenia [1 ,2 ]
Borille, Simona [1 ]
Panteghini, Mauro [1 ,2 ]
机构
[1] ASST Fatebenefratelli Sacco, UOC Patol Clin, Via GB Grassi 74, I-20157 Milan, Italy
[2] Univ Milan, Ctr Ric Riferibilita Metrol Med Lab CIRME, Milan, Italy
关键词
D O I
10.19186/BC_2018.001
中图分类号
Q5 [生物化学]; Q7 [分子生物学];
学科分类号
071010 ; 081704 ;
摘要
The measurement of sFLC kappa and lambda and kappa/lambda ratio calculation is recommended for evaluation and management of plasma cell disorders. However, some analytical issues persist in their measurements, among which a too large long-term imprecision seems to be the main challenge. We evaluated the new Optilite system (The Binding Site) for sFLC determination by comparing its performance with specifications for bias, imprecision (as CV) and total error derived from biological variation of sFLC. We collected data during one year of routine use by employing three reagent lots. The system alignment was checked using the two-level (L and H) Optilite control material by comparing the obtained long-term experimental mean (n=233, both levels) with the manufacturer's assigned values. The protocol for CV evaluation employed the liquid-frozen BioRad Liquichek Control and a frozen serum pool tested for 125 and 79 runs, respectively. Inaccuracy was evaluated by results of four UK-NEQAS exercises [system-specific (Optilite) consensus value as reference]. Average cumulative bias [1.1% (L) and -2.0% (H) for sFLC kappa; 5.4% (L) and 0.1% (H) for sFLC lambda, respectively] fulfilled the desirable goals. CVs for sFLC kappa (7.1% for Liquichek and 6.6% for the pool, respectively), sFLC lambda (7.8% for both Liquichek and the pool) and kappa/lambda ratio (8.9% for Liquichek and 10.2% for the pool, respectively) failed however to reach minimum quality goals. In EQAS evaluation, all sFLC kappa and lambda and 3 out of 4 kappa/lambda ratio results were within the allowable total error. In our experience, the Optilite system shows a good method alignment suitable for sFLC interpretation using fixed cut-offs. However, the assay reproducibility is probably not suitable for optimal long-term monitoring of individual patients.
引用
收藏
页码:32 / 38
页数:7
相关论文
共 50 条
  • [21] Highly sensitive, automated immunoassay for immunoglobulin free light chains in serum and urine
    Bradwell, AR
    Carr-Smith, HD
    Mead, GP
    Tang, LX
    Showell, PJ
    Drayson, MT
    Drew, R
    CLINICAL CHEMISTRY, 2001, 47 (04) : 673 - 680
  • [22] Increased serum concentrations of free immunoglobulin light-chains - A new clinical biomarker for the evaluation of heart failure
    Matsumori, A
    Horii, T
    Nakano, T
    Isomura, T
    Suma, H
    CIRCULATION, 2005, 112 (17) : U819 - U819
  • [23] Serum free light chains
    Forsyth, Julia
    Hill, Peter
    ANNALS OF CLINICAL BIOCHEMISTRY, 2008, 45 : 444 - 445
  • [24] Serum free light chain reference intervals in an Optilite and their influence on clinical guidelines
    Morales-Garcia, Luis J.
    Pacheco-Delgado, Maria S.
    CLINICAL BIOCHEMISTRY, 2021, 92 : 54 - 60
  • [25] A NEW STRATEGY TO REMOVE SERUM FREE LIGHT CHAINS (SFLC) IN PATIENTS WITH MULTIPLE MYELOMA (MM) AND ACUTE KIDNEY INJURY (AKI)
    Festuccia, Francescaromana
    Giammarioli, Elisa
    Fofi, Claudia
    Antolino, Giusy
    La Verde, Giacinto
    Tafuri, Agostino
    Punzo, Giorgio
    Mene, Paolo
    NEPHROLOGY DIALYSIS TRANSPLANTATION, 2015, 30
  • [26] Early Response Using Serum Immunoglobulin Free Light Chain (sFLC) Measurement Predicts Response to Therapy in Waldenstrom Macroglobulinemia (WM)
    Leleu, Xavier
    Roccaro, Aldo M.
    Leduc, Renee
    Poulain, Stephanie
    Moreau, Anne-Sophie
    Gay, Julie
    Dulery, Remy
    Richardson, Paul G.
    Ghobrial, Irene M.
    BLOOD, 2008, 112 (11) : 1286 - 1286
  • [27] DETERMINATION OF KAPPA AND LAMBDA LIGHT-CHAINS IN SERUM IMMUNOGLOBULIN-G, IMMUNOGLOBULIN-A AND IMMUNOGLOBULIN-M
    HARALDSSON, A
    KOCKJANSEN, MJH
    JAMINON, M
    VONECKARTS, PBJM
    DEBOO, T
    WEEMAES, CMR
    BAKKEREN, JAJM
    ANNALS OF CLINICAL BIOCHEMISTRY, 1991, 28 : 461 - 466
  • [28] FREE IMMUNOGLOBULIN LIGHT CHAINS IN COPD MODELS
    Braber, S.
    Blokhuis, B. R.
    Redegeld, F. A.
    Kraneveld, D.
    Folkerts, G.
    NAUNYN-SCHMIEDEBERGS ARCHIVES OF PHARMACOLOGY, 2009, 380 (03) : 270 - 270
  • [29] Quantification of Free Immunoglobulin Light Chains in Urine
    Singh, Gurmukh
    Cotter, Thomas
    Mon, May Ye
    Xu, Hongyan
    Bollag, Roni J.
    JOURNAL OF APPLIED LABORATORY MEDICINE, 2023, 8 (06): : 1101 - 1114
  • [30] Determination of serum free light chains as a marker of systemic lupus flare
    Ana Belén Rodríguez-Cambrón
    Juana Jiménez-Jiménez
    María Ángeles Blázquez-Cañamero
    Francis Rey Pazos
    Cristina Macía-Villa
    María Alcalde-Villar
    Paz Collado-Ramos
    Félix Manuel Cabero Del Pozo
    Eva Álvarez-Andrés
    Ana Cruz-Valenciano
    Clinical Rheumatology, 2020, 39 : 449 - 454