Brachial artery blood flow during submaximal isometric contraction of the biceps brachii and triceps brachii in humans: A preliminary observation

被引:0
|
作者
Ledro, Giulia [1 ]
Turrina, Andrea [2 ]
Picelli, Alessandro [1 ,3 ]
Stecco, Carla [4 ]
Principe, Francesco [5 ]
Cacciatori, Carlo [5 ]
Smania, Nicola [1 ,6 ]
机构
[1] Univ Verona, Neuromotor & Cognit Rehabil Res Ctr, Dept Neurol Neuropsychol Morphol & Movement Sci, Ple LA Scuro 10, I-37134 Verona, Italy
[2] Madrid Sch Osteopathy, Italian Sect, Verona, Italy
[3] Univ Roma La Sapienza, Rome, Italy
[4] Univ Padua, Dept Human Anat & Physiol, Sect Anat, Padua, Italy
[5] Univ Verona, Inst Radiol, Verona, Italy
[6] GB Rossi Univ Hosp, Neurol Rehabil Unit, Verona, Italy
关键词
Brachial artery; Brachial fascia; Blood flow velocity; Diameter; Muscle contraction;
D O I
10.1016/j.jbmt.2012.07.014
中图分类号
R49 [康复医学];
学科分类号
100215 ;
摘要
The purpose of this study was to evaluate brachial artery blood flow changes during submaximal isometric contraction of the biceps and triceps brachii, in order to clarify the influence of the upper arm muscles activity on the local arterial flow. The brachial artery blood flow velocity and diameter were evaluated in twenty healthy men (mean age 29.6 years) at baseline (resting position) and during submaximal isometric contraction of the biceps and triceps brachii by means of ultrasonography (B-MODE and Doppler ultrasound methods). The brachial artery blood flow velocity was significantly higher than resting position during submaximal isometric contraction of the biceps (P < 0.001) and triceps brachii (P = 0.019). As to the brachial artery diameter, no significant change was observed during submaximal isometric contractions of the biceps and triceps brachii. Our preliminary findings suggest that the brachial artery blood flow velocity similarly increases during submaximal isometric contraction of the biceps and triceps brachii. (C) 2012 Elsevier Ltd. All rights reserved.
引用
收藏
页码:165 / 168
页数:4
相关论文
共 36 条
  • [21] Localized Electrical Impedance Myography of the Biceps Brachii Muscle during Different Levels of Isometric Contraction and Fatigue
    Li, Le
    Shin, Henry
    Li, Xiaoyan
    Li, Sheng
    Zhou, Ping
    SENSORS, 2016, 16 (04):
  • [22] Effect of innervation zones in estimating biceps brachii force-EMG relationship during isometric contraction
    Rantalainen, Timo
    Klodowski, Adam
    Piitulainen, Harri
    JOURNAL OF ELECTROMYOGRAPHY AND KINESIOLOGY, 2012, 22 (01) : 80 - 87
  • [23] Differential control of blood flow in masseter and biceps brachii muscles during stress
    Rashid, Anas
    Roatta, Silvestro
    ARCHIVES OF ORAL BIOLOGY, 2022, 141
  • [25] Acoustic and electrical activities during voluntary isometric contraction of biceps brachii muscles in patients with spastic cerebral palsy
    Akataki, K
    Mita, K
    Itoh, K
    Suzuki, N
    Watakabe, M
    MUSCLE & NERVE, 1996, 19 (10) : 1252 - 1257
  • [26] Changes in synchronization of the motor unit in muscle fatigue condition during the dynamic and isometric contraction in the Biceps Brachii muscle
    Liu, Xiangyu
    Zhou, Meiyu
    Geng, Yanjuan
    Meng, Long
    Wan, Huiying
    Ren, Haoran
    Zhang, Xinyue
    Dai, Chenyun
    Chen, Wei
    Ye, Xinming
    NEUROSCIENCE LETTERS, 2021, 761
  • [27] Correlations Between Myoelectric and Hemodynamic Parameters Changes in Biceps Brachii During Sustained Isometric Contraction in Healthy Elderly
    Zampella C.
    Calanni L.
    Barbero M.
    Cescon C.
    Giovanetti G.
    Negro M.
    D’Antona G.
    Journal of Science in Sport and Exercise, 2019, 1 (2) : 116 - 123
  • [28] Sex-related differences in corticospinal excitability outcome measures of the biceps brachii during a submaximal elbow flexor contraction
    Olarogba, Olalekan B.
    Lockyer, Evan J.
    Antolinez, Angie K.
    Button, Duane C.
    PHYSIOLOGICAL REPORTS, 2024, 12 (15):
  • [29] Fatigue analysis of interference EMG signals obtained from biceps brachii during isometric voluntary contraction at various force levels
    Dimitrova, N. A.
    Arabadzhiev, T. I.
    Hogrel, J. -Y.
    Dimitrov, G. V.
    JOURNAL OF ELECTROMYOGRAPHY AND KINESIOLOGY, 2009, 19 (02) : 252 - 258
  • [30] Behavior of oxygen saturation and blood filling in the venous capillary system of the biceps brachii muscle during a fatiguing isometric action
    Dech, Silas
    Bittmann, Frank
    Schaefer, Laura
    EUROPEAN JOURNAL OF TRANSLATIONAL MYOLOGY, 2020, 30 (01) : 79 - 87