DISPOSABLE GLUCOSE SENSOR PLATE AND DISPOSABLE MULTIION SENSOR PLATE

被引:0
|
作者
MOCHIZUKI, A
HIRAKUNI, S
IIDA, H
机构
[1] Advanced Research Department, Taiyo Yuden Co. Ltd., Gunma, 370-33, 562 Hongo-Tsukanaka, Haruna-machi
关键词
D O I
10.1016/0925-4005(90)80262-X
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A disposable glucose sensor plate and a disposable multi-ion sensor plate sensitive to sodium, potassium, chloride and hydrogen ions have been developed for clinical use. For a disposable-type sensor, simplicity of operation, especially the elimination of calibration, is necessary in addition to measurement accuracy and precision. To obtain a stable potential, a simple reference electrode was fabricated on a plate together with the ion-sensitive electrode using electrolyte gel cake on a Ag/AgCl electrode. The ion sensors had a sensitivity of 55-58 mV/dec and showed a linear response relative to the logarithm of each ion activity. The response to a given solution was reproducible to within approximately ±1.0 mV, corresponding to a final error of ±4% without any electrode calibration. The glucose sensor plate was prepared by immobilization of GOD over the pH electrode of the sensor plate. Responses to a given glucose solution ranging from 10 to 250 mg/dl were obtained and were reproducible to within approximately 8% in a normal glucose range without calibration before use. These results suggest that further improvement is necessary in order to obtain uniform electrode electrochemical characteristics, so that clinical application without pre-use calibration can be achieved. © 1990.
引用
收藏
页码:510 / 513
页数:4
相关论文
共 50 条
  • [31] A disposable microbial sensor for rapid BOD measurement
    Anjum, M
    Shekhar, H
    Hyun, SH
    Cho, HJ
    Micro Total Analysis Systems 2004, Vol 2, 2005, (297): : 306 - 308
  • [32] DISPOSABLE SOLID-STATE OXYGEN SENSOR
    KIMMICH, HP
    KUYPERS, MH
    ENGELS, JML
    MAAS, HGR
    ADVANCES IN EXPERIMENTAL MEDICINE AND BIOLOGY, 1983, 159 : 83 - 92
  • [33] Defence applications of Disposable Organic Sensor Networks
    Beale, DAR
    Hume, AL
    Hodges, RN
    Calloway, VP
    Kimber, SD
    UNMANNED/UNATTENDED SENSORS AND SENSOR NETWORKS, 2004, 5611 : 156 - 167
  • [34] Disposable chemiluminometric sensor for rapid determination of EDTA
    Younes Taferssiti Zarouila
    Maria Del Carmen Valencia Mirón
    Luís Fermín Capitán-Vallvey
    Microchimica Acta, 2007, 157 : 63 - 71
  • [35] Disposable sensor for electrochemical determination of chloride ions
    Bujes-Garrido, Julia
    Julia Arcos-Martinez, M.
    TALANTA, 2016, 155 : 153 - 157
  • [36] Disposable sensor detects "shoe bomb" explosive
    Bushee, Margaret W.
    PHOTONICS SPECTRA, 2011, 45 (01) : 21 - 23
  • [37] Piezoresistive disposable weight sensor with increased sensitivity
    Erdil, Kuter
    Ayrac, Tugce
    Akcan, O. Gokalp
    Gokdel, Y. Daghan
    TURKISH JOURNAL OF ELECTRICAL ENGINEERING AND COMPUTER SCIENCES, 2020, 28 (02) : 984 - 998
  • [38] Simple quantitative measurement of glycogen in shell ligament using disposable blood glucose sensor
    Wada, N
    Takimoto, S
    Tokunaga, H
    Baba, H
    JOURNAL OF THE JAPANESE SOCIETY FOR FOOD SCIENCE AND TECHNOLOGY-NIPPON SHOKUHIN KAGAKU KOGAKU KAISHI, 1997, 44 (02): : 153 - 155
  • [39] Facile and scalable disposable sensor based on laser engraved graphene for electrochemical detection of glucose
    Farshad Tehrani
    Behzad Bavarian
    Scientific Reports, 6
  • [40] Performance of a New Disposable Zero-Calibration Continuous Glucose Monitoring (CGM) Sensor
    Bode, Bruce W.
    Bailey, Timothy S.
    Castorino, Kristin N.
    Christiansen, Mark P.
    Garg, Satish K.
    Kaiserman, Kevin B.
    Liljenquist, David R.
    Shulman, Dorothy I.
    Slover, Robert H.
    Shin, John
    Peng, Fen
    Huang, Suiying
    Rhinehart, Andrew S.
    Vigersky, Robert A.
    DIABETES, 2022, 71