DISPOSABLE GLUCOSE SENSOR PLATE AND DISPOSABLE MULTIION SENSOR PLATE

被引:0
|
作者
MOCHIZUKI, A
HIRAKUNI, S
IIDA, H
机构
[1] Advanced Research Department, Taiyo Yuden Co. Ltd., Gunma, 370-33, 562 Hongo-Tsukanaka, Haruna-machi
关键词
D O I
10.1016/0925-4005(90)80262-X
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A disposable glucose sensor plate and a disposable multi-ion sensor plate sensitive to sodium, potassium, chloride and hydrogen ions have been developed for clinical use. For a disposable-type sensor, simplicity of operation, especially the elimination of calibration, is necessary in addition to measurement accuracy and precision. To obtain a stable potential, a simple reference electrode was fabricated on a plate together with the ion-sensitive electrode using electrolyte gel cake on a Ag/AgCl electrode. The ion sensors had a sensitivity of 55-58 mV/dec and showed a linear response relative to the logarithm of each ion activity. The response to a given solution was reproducible to within approximately ±1.0 mV, corresponding to a final error of ±4% without any electrode calibration. The glucose sensor plate was prepared by immobilization of GOD over the pH electrode of the sensor plate. Responses to a given glucose solution ranging from 10 to 250 mg/dl were obtained and were reproducible to within approximately 8% in a normal glucose range without calibration before use. These results suggest that further improvement is necessary in order to obtain uniform electrode electrochemical characteristics, so that clinical application without pre-use calibration can be achieved. © 1990.
引用
收藏
页码:510 / 513
页数:4
相关论文
共 50 条
  • [1] Disposable percutaneous glucose sensor
    Liao, K.
    Hogen-Esch, T.
    Richmond, F.
    Marcu, L.
    Loeb, G.
    2006 BIO- MICRO- AND NANOSYSTEMS CONFERENCE, 2006, : 101 - 101
  • [2] DEVELOPMENT OF DISPOSABLE GLUCOSE SENSOR
    NANKAI, S
    YOSHIOKA, T
    ADACHI, KI
    ISHIHARA, T
    TSUTSUMI, H
    NISHIMOTO, S
    DENKI KAGAKU, 1995, 63 (07): : 592 - 595
  • [3] Design and fabrication of a disposable, percutaneous glucose sensor
    Liao, Kuo-Chih
    Hogen-Esch, Thieo
    Richmond, Frances J.
    Marcu, Laura
    Clifton, William
    Loeb, Gerald E.
    OPTICAL FIBERS AND SENSORS FOR MEDICAL DIAGNOSTICS AND TREATMENT APPLICATIONS VI, 2006, 6083
  • [4] DISPOSABLE GLUCOSE SENSOR EMPLOYING POTASSIUM FERRICYANIDE AS A MEDIATOR
    KAWAGURI, M
    YOSHIOKA, T
    NANKAI, S
    DENKI KAGAKU, 1990, 58 (12): : 1119 - 1124
  • [5] Disposable Microfluidic Sensor Based on Nanocellulose for Glucose Detection
    Uddin, Khan Mohammad Ahsan
    Jokinen, Ville
    Ahangiri, Farzin
    Franssila, Sarni
    Rojas, Orlando J.
    Tuukkanen, Sampo
    GLOBAL CHALLENGES, 2019, 3 (02)
  • [6] NEW DISPOSABLE PARALLEL PLATE DIALYZER
    ACKERMAN, RA
    FIALKOFF, SL
    ARTIFICIAL ORGANS, 1977, 1 (01) : 119 - 119
  • [7] A NEW DISPOSABLE PLATE-KIDNEY
    FUNCKBRENTANO, JL
    SAUSSE, A
    VANTELON, J
    GRANGER, A
    ZINGRAFF, J
    MAN, NK
    TRANSACTIONS AMERICAN SOCIETY FOR ARTIFICIAL INTERNAL ORGANS, 1969, 15 : 127 - +
  • [8] A disposable blood cyanide sensor
    Tian, Yong
    Dasgupta, Purnendu K.
    Mahon, Sari B.
    Ma, Jian
    Brenner, Matthew
    Jian-HuaWang
    Boss, Gerry R.
    ANALYTICA CHIMICA ACTA, 2013, 768 : 129 - 135
  • [9] Development of disposable electrochemical sensor with replaceable glucose oxidase tip
    Wen, ZH
    Lju, DX
    Ye, BX
    Zhou, XY
    ANALYTICAL COMMUNICATIONS, 1997, 34 (01): : 27 - 30
  • [10] A fully inkjet-printed disposable glucose sensor on paper
    Bihar, Eloise
    Wustoni, Shofarul
    Pappa, Anna Maria
    Salama, Khaled N.
    Baran, Derya
    Inal, Sahika
    NPJ FLEXIBLE ELECTRONICS, 2018, 2 (01)