CHARACTERISTICS OF A SILICON DETECTOR FOR INDUSTRIAL X-RAY COMPUTED-TOMOGRAPHY

被引:3
|
作者
MIYAI, H
KITAGUCHI, H
KAWASAKI, S
IZUMI, S
机构
[1] Energy Research Laboratory, Hitachi Ltd., Hitachi-shi, Ibaraki-ken, 319-12
关键词
D O I
10.1016/0168-9002(94)91611-X
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
We have evaluated a silicon solid state detector (Si-SSD) as a detector for Industrial X-ray Computed Tomography (IXCT) from the viewpoints of sensitivity and radiation damage. The detector which we used in this work, is a diffused junction type Si-SSD (43 X 3.8 X 0.5 mm) fabricated on high purity n-type silicon. We measured pulse height distributions for narrow pencil beam Co-60 gamma rays parallelly incident to the detector. The expected deposit energy was 0.146 +/- 0.001 MeV (11.7% of the incident photon energy). The calculated pulse height distribution using the general purpose EGS4 code was confirmed to be in good agreement with the measured one. The radiation damage was evaluated using the Co-60 gamma ray source. Exposure of up to 88 kGy(Si) was achieved over a period of 20 hours, with an exposure rate of 4.4 kGy(Si)/h (36 mC/kg s). It was confirmed that the Si-SSDs could be used at least up to 88 kGy(Si) with X-rays equivalent to Co-60 gamma rays.
引用
收藏
页码:97 / 100
页数:4
相关论文
共 50 条
  • [11] CERAMIC SCINTILLATORS FOR X-RAY COMPUTED-TOMOGRAPHY
    GRABMAIER, BC
    ROSSNER, W
    LEPPERT, J
    PHYSICA STATUS SOLIDI A-APPLICATIONS AND MATERIALS SCIENCE, 1992, 130 (02): : K183 - K187
  • [12] THE EFFECTS OF SCATTER IN X-RAY COMPUTED-TOMOGRAPHY
    JOSEPH, PM
    SPITAL, RD
    MEDICAL PHYSICS, 1982, 9 (04) : 464 - 472
  • [13] VIDEO BASED X-RAY COMPUTED-TOMOGRAPHY
    QU, LZ
    NALCIOGLU, O
    ROECK, WW
    RABBANI, B
    COLMAN, M
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1986, 33 (01) : 527 - 530
  • [14] RING ARTIFACTS IN X-RAY COMPUTED-TOMOGRAPHY
    CRANAGE, RW
    TOFTS, PS
    BRITISH JOURNAL OF RADIOLOGY, 1988, 61 (726): : 529 - 529
  • [15] NEW SCINTILLATORS FOR X-RAY COMPUTED-TOMOGRAPHY
    GRABMAIER, BC
    ROSSNER, W
    NUCLEAR TRACKS AND RADIATION MEASUREMENTS, 1993, 21 (01): : 43 - 45
  • [16] REGION-OF-INTEREST (ROI) MODE IN INDUSTRIAL X-RAY COMPUTED-TOMOGRAPHY
    REIMERS, P
    KETTSCHAU, A
    GOEBBELS, J
    NDT INTERNATIONAL, 1990, 23 (05): : 255 - 261
  • [17] APPLICATIONS OF X-RAY COMPUTED-TOMOGRAPHY TO COAL STUDIES
    MAYLOTTE, DH
    KOSKY, PG
    LAMBY, EJ
    SPIRO, CL
    DAVIS, A
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1984, 187 (APR): : 6 - FUEL
  • [18] THE APPLICATION OF X-RAY COMPUTED-TOMOGRAPHY TO MATERIALS DEVELOPMENT
    BOSSI, RH
    GEORGESON, GE
    JOM-JOURNAL OF THE MINERALS METALS & MATERIALS SOCIETY, 1991, 43 (09): : 8 - 15
  • [19] THE LARGEST AND SMALLEST X-RAY COMPUTED-TOMOGRAPHY SYSTEMS
    BURSTEIN, P
    BJORKHOLM, PJ
    CHASE, RC
    SEGUIN, FH
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1984, 221 (01): : 207 - 212
  • [20] HYBRID RECONSTRUCTION ALGORITHM FOR X-RAY COMPUTED-TOMOGRAPHY
    WAGGENER, R
    LEE, M
    MICKISH, D
    LANGE, J
    FELDMEIER, J
    MEDICAL PHYSICS, 1989, 16 (02) : 197 - 201