TOPEX-POSEIDON MICROWAVE RADIOMETER PERFORMANCE AND IN-FLIGHT CALIBRATION

被引:65
|
作者
RUF, CS
KEIHM, SJ
SUBRAMANYA, B
JANSSEN, MA
机构
[1] BALL CORP, PASADENA, CA USA
[2] HUGHES STX, LANHAM, MD USA
[3] CALTECH, JET PROP LAB, PASADENA, CA USA
关键词
D O I
10.1029/94JC00717
中图分类号
P7 [海洋学];
学科分类号
0707 ;
摘要
Results of the in-flight calibration and performance evaluation campaign for the TOPEX/POSEIDON microwave radiometer (TMR) are presented. Intercomparisons are made between TMR and various sources of ground truth, including ground-based microwave water vapor radiometers, radiosondes, global climatological models, special sensor microwave imager data over the Amazon rain forest, and models of clear, calm, subpolar ocean regions. After correcting for preflight errors in the processing of thermal/vacuum data, relative channel offsets in the open ocean TMR brightness temperatures were noted at the approximate to 1 K level for the three TMR frequencies. Larger absolute offsets of 6-9 K over the rain forest indicated a approximate to 5% gain error in the three channel calibrations. This was corrected by adjusting the antenna pattern correction (APC) algorithm. A 10% scale error in the TMR path delay estimates, relative to coincident radiosondes, was corrected in part by the APC adjustment and in part by a 5% modification to the value assumed for the 22.235 GHz water vapor line strength in the path delay retrieval algorithm. After all in-flight corrections to the calibration, TMR global retrieval accuracy for the wet tropospheric range correction is estimated at 1.1 cm RMS with consistent performance under clear, cloudy, and windy conditions.
引用
收藏
页码:24915 / 24926
页数:12
相关论文
共 50 条
  • [31] Global mean sea level changes observed by Topex-Poseidon and ERS-1
    Cazenave, A.
    Dominh, K.
    Gennero, M.C.
    Ferret, B.
    Physics and Chemistry of the Earth, 23 (9-10): : 1069 - 1075
  • [32] Microwave Radiometer Calibration on Decadal Time Scales Using On-Earth Brightness Temperature References: Application to the TOPEX Microwave Radiometer
    Brown, Shannon
    Desai, Shailen
    Keihm, Stephen
    Lu, Wenwen
    JOURNAL OF ATMOSPHERIC AND OCEANIC TECHNOLOGY, 2009, 26 (12) : 2579 - 2591
  • [33] Microwave radiometer calibration on decadal time scales using on-earth brightness temperature references: Application to the TOPEX microwave radiometer
    Brown, Shannon
    Desai, Shailen
    Keihm, Stephen
    Lu, Wenwen
    Journal of Atmospheric and Oceanic Technology, 2009, 26 (12): : 2579 - 2591
  • [34] Use of the Topex-Poseidon dual-frequency radar altimeter over land surfaces
    Papa, F
    Legresy, B
    Rémy, F
    REMOTE SENSING OF ENVIRONMENT, 2003, 87 (2-3) : 136 - 147
  • [35] The use of Topex-Poseidon, ERS-1 and ERS-2 altimeters to detect meddles
    Villares, P
    Bruno, M
    Alonso, JJ
    Ruiz-Cañavate, A
    Catalán, M
    Catalán, M
    REMOTE SENSING IN THE 21ST CENTURY: ECONOMIC AND ENVIRONMENTAL APPLICATIONS, 2000, : 449 - 454
  • [36] In-flight performance and calibration of the autonomous minisatellite PROBA
    de Lafontaine, J
    Lafleur, JR
    Jean, I
    Van den Braembussche, P
    Vuilleumier, P
    SPACEFLIGHT MECHANICS 2003, PTS 1-3, 2003, 114 : 801 - 819
  • [37] AirMISR laboratory calibration and in-flight performance results
    Chrien, NL
    Bruegge, CJ
    Gaitley, BJ
    REMOTE SENSING OF ENVIRONMENT, 2001, 77 (03) : 328 - 337
  • [38] Global oceanic precipitation: A joint view by TOPEX and the TOPEX microwave radiometer
    Chen, G
    Chapron, B
    Tournadre, J
    Katsaros, K
    Vandemark, D
    JOURNAL OF GEOPHYSICAL RESEARCH-OCEANS, 1997, 102 (C5): : 10457 - 10471
  • [39] CALIBRATION OF THE TOPEX/POSEIDON ALTIMETERS AT LAMPEDUSA - ADDITIONAL RESULTS AT HARVEST
    MENARD, Y
    JEANSOU, E
    VINCENT, P
    JOURNAL OF GEOPHYSICAL RESEARCH-OCEANS, 1994, 99 (C12) : 24487 - 24504
  • [40] SWS in-flight calibration
    Shipman, RF
    Morris, PW
    Beintema, DA
    Boxhoorn, DR
    Feuchtgruber, H
    Heras, AM
    Huygen, R
    Kester, DJM
    Lahuis, F
    Leech, K
    Lorente, R
    Lutz, D
    Roelfsema, PR
    Salama, A
    Schaeidt, SG
    Valentijn, EA
    Vandenbussche, B
    Wieprecht, E
    PROCEEDINGS OF THE CONFERENCE ON THE CALIBRATION LEGACY OF THE ISO MISSION, 2003, 481 : 107 - 111