LINEAR STAPLING DEVICE IN PARTIAL RESECTION OF ABDOMINAL PARENCHYMATOUS ORGANS

被引:0
|
作者
SCHEIN, M
BANIEL, J
DEGIDIO, A
HASHMONAI, M
机构
关键词
D O I
暂无
中图分类号
R61 [外科手术学];
学科分类号
摘要
The use of the linear stapling device (LSD) is well-established in hollow-organ gastro-intestinal surgery. Its use in operations performed on parenchymatous viscera is less common. We present our experiences with the LSD in partial resection of the spleen (2 cases), pancreas (5 cases), liver (2 cases) and kidney (2 cases). To the best of our knowledge the use of the LSD for partial nephrectomy and resectional debridement of the liver has not been previously described. We suggest that LSDs are useful aids in the resection of parenchymatous organs, and allow rapid resection if applied to healthy tissues and in regions with an intact capsule.
引用
收藏
页码:47 / 48
页数:2
相关论文
共 50 条
  • [21] PHARYNGOESOPHAGEAL DIVERTICULUM SURGICAL THERAPY USING LINEAR STAPLING DEVICE
    Braga de Aquino, Jose Luis
    Said, Marcelo Manzano
    Salles Chagas, Jose Francisco
    Leandro-Merhi, Vania Aparecida
    Gallo-Junior, Eusebio Jose
    Cecchino, Gustavo Nardini
    Assuncao, Mayra Todeschini
    ABCD-ARQUIVOS BRASILEIROS DE CIRURGIA DIGESTIVA-BRAZILIAN ARCHIVES OF DIGESTIVE SURGERY, 2012, 25 (02): : 91 - 95
  • [22] LOCAL RECURRENCE AFTER LOW ANTERIOR RESECTION USING THE EEA STAPLING DEVICE
    ZIV, Y
    BENBARUCH, D
    WAIZER, A
    FLEX, D
    WOLLOCH, Y
    DISEASES OF THE COLON & RECTUM, 1988, 31 (12) : 945 - 947
  • [23] Sequential linear stapling technique for perineal resection of intractable pediatric rectal prolapse
    Lee, Jong In
    Vogel, Adam M.
    Suchar, Adam M.
    Glynn, Loretto
    Statter, Mindy B.
    Liu, Donald C.
    AMERICAN SURGEON, 2006, 72 (12) : 1212 - 1215
  • [24] Retroperitoneoscopic partial adrenalectomy using an endoscopic stapling device in patients with adrenal tumor
    Sasagawa, I
    Suzuki, H
    Tateno, T
    Izumi, T
    Shoji, N
    Nakada, T
    UROLOGIA INTERNATIONALIS, 1998, 61 (02) : 101 - 103
  • [25] Resection of parenchymatous organs using pulse YAG:Nd laser radiation at 1.44 μm and 1.32 μm wavelengths
    Zubeev, P
    Rotkov, A
    Vaganov, I
    Skvortsova, I
    Kamensky, V
    Gelikonov, G
    Sergeev, A
    LASERS IN SURGERY: ADVANCED CHARACTERIZATION, THERAPEUTICS, AND SYSTEMS IX, PROCEEDINGS OF, 1999, 3590 : 439 - 443
  • [26] Anastomotic Leakage Using Linear Stapling Device with Pre-attached Bioabsorbable Polyglycolic Acid Felt After Laparoscopic Anterior Resection
    Yamamoto, Seiichiro
    Kanai, Toshio
    Osumi, Koji
    Yo, Kikuo
    Takano, Kiminori
    Tsutsui, Mai
    Nakanishi, Ryo
    Yoshikawa, Yusuke
    Kaneko, Yasushi
    Nakagawa, Motohito
    ANTICANCER RESEARCH, 2017, 37 (12) : 7083 - 7086
  • [27] SURGICAL TACTICS IN INJURIES OF THE PARENCHYMATOUS ORGANS OF THE ABDOMINAL-CAVITY AND RETROPERITONEAL SPACE IN CHILDREN (A CLINICAL AND EXPERIMENTAL INVESTIGATION)
    STEPANOV, EA
    SMIRNOV, AN
    SAMSYGIN, SA
    KUZNECHIKHIN, EP
    KOSTOMAROVA, TD
    BELYKH, SI
    AKIMOVA, AY
    FIRSOVA, EV
    KHIRURGIYA, 1985, (07): : 46 - 50
  • [28] CUTANEOUS PERIANAL RECURRENCE OF CANCER AFTER ANTERIOR RESECTION USING THE EEA STAPLING DEVICE
    DEFRIEND, DJ
    KRAMER, E
    PRESCOTT, R
    CORSON, J
    GALLAGHER, P
    ANNALS OF THE ROYAL COLLEGE OF SURGEONS OF ENGLAND, 1992, 74 (02) : 142 - 143
  • [30] THE EEA-STAPLING DEVICE IN ANTERIOR RESECTION FOR CARCINOMA OF THE RECTUM - TECHNIQUE AND EARLY RECCURENCES
    ANDERBERG, B
    ENBLAD, P
    SJODAHL, R
    WETTERFORS, J
    ACTA CHIRURGICA SCANDINAVICA, 1983, 149 (01): : 99 - 103