A novel detection method for the cardiac glycosides digitoxin, digoxin, and their metabolites is described. Both isocratic and gradient water-acetonitrile elutions were employed with an octadecylsilane column. The effluent was monitored by integrated pulsed amperometry in an alkaline medium (pH>12) by adding sodium hydroxide post-column. Using isocratic elution, peak responses were linear from 10 to 70 ng, with lower limits of detection between 4 and 15 ng. This method allows easy modification of well-estalished high-performance liquid chromatographic systems, as well as comparable sensitivity and greater selectivity than UV detection.
引用
收藏
页码:289 / 295
页数:7
相关论文
共 50 条
  • [31] QUANTITATION OF NIZATIDINE IN CAPSULES USING HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY
    MATHEW, M
    DASGUPTA, V
    BETHEA, C
    DRUG DEVELOPMENT AND INDUSTRIAL PHARMACY, 1993, 19 (12) : 1497 - 1503
  • [32] QUANTITATION OF BACLOFEN IN TABLETS USING HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY
    DASGUPTA, V
    JOURNAL OF LIQUID CHROMATOGRAPHY, 1987, 10 (04): : 749 - 755
  • [33] QUANTITATION OF PYRIDOSTIGMINE IN PLASMA USING HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY
    YAKATAN, GJ
    TIEN, JY
    JOURNAL OF CHROMATOGRAPHY, 1979, 164 (03): : 399 - 403
  • [34] QUANTITATION OF BENZOYLNORECGONINE AND OTHER COCAINE METABOLITES IN MECONIUM BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY
    MURPHEY, LJ
    OLSEN, GD
    KONKOL, RJ
    JOURNAL OF CHROMATOGRAPHY-BIOMEDICAL APPLICATIONS, 1993, 613 (02): : 330 - 335
  • [35] ESTIMATION OF THE DISTRIBUTIONS OF CHAIN-LENGTH OF AMYLOPECTINS BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY WITH PULSED AMPEROMETRIC DETECTION
    KOIZUMI, K
    FUKUDA, M
    HIZUKURI, S
    JOURNAL OF CHROMATOGRAPHY, 1991, 585 (02): : 233 - 238
  • [36] SUGAR ANALYSIS OF GLYCOPROTEINS AND GLYCOLIPIDS AFTER METHANOLYSIS BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY WITH PULSED AMPEROMETRIC DETECTION
    LAMPIO, A
    FINNE, J
    ANALYTICAL BIOCHEMISTRY, 1991, 197 (01) : 132 - 136
  • [37] QUANTITATION OF METOLAZONE IN URINE BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY WITH FLUORESCENCE DETECTION
    FARTHING, D
    FAKHRY, I
    GEHR, TWB
    SICA, DA
    JOURNAL OF CHROMATOGRAPHY-BIOMEDICAL APPLICATIONS, 1990, 534 : 228 - 232
  • [38] QUANTITATION OF OXYCODONE IN HUMAN PLASMA USING HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY WITH ELECTROCHEMICAL DETECTION
    SMITH, MT
    WATT, JA
    MAPP, GP
    CRAMOND, T
    THERAPEUTIC DRUG MONITORING, 1991, 13 (02) : 126 - 130
  • [39] HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY AND UV DETECTION FOR THE SEPARATION AND QUANTITATION OF PROSTAGLANDINS
    TERRAGNO, A
    RYDZIK, R
    TERRAGNO, NA
    PROSTAGLANDINS, 1981, 21 (01): : 101 - 112
  • [40] QUANTITATION OF SERUM TOCOPHEROLS BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY WITH FLUORESCENCE DETECTION
    JANSSON, L
    NILSSON, B
    LINDGREN, R
    JOURNAL OF CHROMATOGRAPHY, 1980, 181 (02): : 242 - 247