UNSTENTED SEMILUNAR HOMOGRAFT REPLACEMENT OF TRICUSPID-VALVE IN EBSTEINS MALFORMATION

被引:7
|
作者
KUMAR, N
GALLO, R
ALHALEES, Z
ALFADLEY, F
DURAN, CMG
机构
[1] Department of Cardiovascular Diseases, King Faisal Specialist Hospital, Research Centre, Riyadh
来源
ANNALS OF THORACIC SURGERY | 1995年 / 59卷 / 02期
关键词
D O I
10.1016/0003-4975(94)00803-F
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Tricuspid valve pathology in Ebstein's malformation requires replacement when it is not possible to repair or reconstruct this valve. In smaller children, in whom the right-sided atrioventricular valve is severely dysplastic and right ventricular volume is prohibitive, prosthetic replacement is not always possible. We report here on 3 patients who underwent stentless semilunar homograft replacement (top-hat procedure) of tricuspid valve for Ebstein's anomaly with good short-term outcome. This provides an attractive alternative in the management of a certain difficult subset of patients, avoids long term anticoagulation and probably is more durable.
引用
收藏
页码:320 / 322
页数:3
相关论文
共 50 条
  • [31] EBSTEINS MALFORMATION OF TRICUSPID VALVE - REVIEW OF 65 CASES
    BIALOSTOZKY, D
    HORWITZ, S
    ESPINOVE.J
    AMERICAN JOURNAL OF CARDIOLOGY, 1972, 29 (06): : 826 - +
  • [32] MR-IMAGING OF EBSTEINS-ANOMALY OF THE TRICUSPID-VALVE
    CHOI, YH
    PARK, JH
    CHOE, YH
    YOO, SJ
    AMERICAN JOURNAL OF ROENTGENOLOGY, 1994, 163 (03) : 539 - 543
  • [33] RESULTS OF MITRAL VALVE REPLACEMENT USING UNSTENTED FRESH SEMILUNAR VALVE HOMOGRAFTS
    YACOUB, MH
    TOWERS, M
    SOMERVIL.W
    CIRCULATION, 1971, 44 (04) : 70 - &
  • [34] ECHOCARDIOGRAPHIC CRITERIA FOR EBSTEINS-ANOMALY OF TRICUSPID-VALVE - REPLY
    GUSSENHOVEN, WJ
    SPITAELS, SEC
    BOM, N
    BECKER, AE
    BRITISH HEART JOURNAL, 1980, 44 (02): : 231 - 231
  • [35] A NEW RECONSTRUCTIVE OPERATION FOR EBSTEINS-ANOMALY OF THE TRICUSPID-VALVE
    CARPENTIER, A
    CHAUVAUD, S
    MACE, L
    RELLAND, J
    MIHAILEANU, S
    MARINO, JP
    ABRY, B
    GUIBOURT, P
    JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 1988, 96 (01): : 92 - 101
  • [36] PROSTHETIC REPLACEMENT OF TRICUSPID VALVE FOR EBSTEINS ANOMALY
    MANNIX, EP
    BERROYA, RB
    JOURNAL OF CARDIOVASCULAR SURGERY, 1971, 12 (05): : 355 - &
  • [37] MITRAL VALVE REPLACEMENT USING HOMOGRAFT SEMILUNAR VALVES
    ROSS, JK
    BRITISH HEART JOURNAL, 1971, 33 (01): : 145 - &
  • [38] REPLACEMENT OF CANINE TRICUSPID VALVE WITH A SEMILUNAR HETEROGRAFT
    GILBERT, JW
    GRAVANIS, MB
    MANSOUR, K
    TRAER, J
    JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 1968, 56 (01): : 88 - &
  • [39] TRICUSPID-VALVE ENDOCARDITIS - PROSTHETIC REPLACEMENT
    VIDNE, B
    LEVY, MJ
    JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 1974, 68 (01): : 47 - 50
  • [40] TRICUSPID-VALVE REPAIR FOR TRICUSPID-VALVE ENDOCARDITIS - TRICUSPID-VALVE RECYCLING
    ALLEN, MD
    SLACHMAN, F
    EDDY, AC
    COHEN, D
    OTTO, CM
    PEARLMAN, AS
    ANNALS OF THORACIC SURGERY, 1991, 51 (04): : 593 - 598