THE EFFECTS OF LUMINANCE ON FPL AND VEP ACUITY IN HUMAN INFANTS

被引:22
|
作者
ALLEN, D
BENNETT, PJ
BANKS, MS
机构
[1] UNIV CALIF BERKELEY,SCH OPTOMETRY,BERKELEY,CA 94720
[2] UNIV CALIF BERKELEY,DEPT PSYCHOL,BERKELEY,CA 94720
关键词
INFANT VISUAL DEVELOPMENT; ACUITY; PREFERENTIAL LOOKING; VISUAL EVOKED POTENTIALS;
D O I
10.1016/0042-6989(92)90061-M
中图分类号
Q189 [神经科学];
学科分类号
071006 ;
摘要
Grating acuity was measured in 16-week-old human infants. Three measurement techniques were used: forced-choice preferential-looking (FPL), and two visual-evoked-potential (VEP) techniques. The stimuli were counterphase flickering sinewave gratings with a space-average luminance of -1.0 or 2.0 log cd/m2. Slightly different luminance-dependent changes occur between FPL and VEP acuities, suggesting that some factor influences the two methods differently as stimulus luminance varies. A comparison between FPL acuities and VEP acuities within infants suggests a quantitative relationship between techniques. Infant's acuity for sinewave gratings with a space-average luminance of -2.0, -1.0, 0.0, 1.0 and 2.0 log cd/m2 was also measured using a single VEP paradigm. The results are compared to the same measurements in adults and to infant and adult ideal observers. VEP acuity in this group of infants improves by about 0.5 log units between -2.0 and 0.0 log cd/m2 and remains asymptotic between 0.0 and 2.0 log cd/m2. This result suggests that luminance-dependent changes in infant acuity cannot be fully accounted for by immaturities in the optics and photoreceptor spacing and efficiency.
引用
收藏
页码:2005 / 2012
页数:8
相关论文
共 50 条
  • [41] SPECTRAL-ANALYSIS OF THE VISUAL EVOKED-POTENTIAL (VEP) - EFFECTS OF STIMULUS LUMINANCE
    JUTAI, JW
    GRUZELIER, JH
    CONNOLLY, JF
    PSYCHOPHYSIOLOGY, 1984, 21 (06) : 665 - 672
  • [42] GRATING ACUITY OF THE GOLDEN-HAMSTER - EFFECTS OF STIMULUS ORIENTATION AND LUMINANCE
    EMERSON, VF
    EXPERIMENTAL BRAIN RESEARCH, 1980, 38 (01) : 43 - 52
  • [43] Visual acuity outcomes measured by sweep-VEP in infants with dense congenital unilateral cataract.
    Salomao, SR
    Birch, EE
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 1997, 38 (04) : 4625 - 4625
  • [44] LUMINANCE EFFECTS ON VISUAL-ACUITY AND SMALL LETTER CONTRAST SENSITIVITY
    RABIN, J
    OPTOMETRY AND VISION SCIENCE, 1994, 71 (11) : 685 - 688
  • [45] VEP estimation of visual acuity: a systematic review
    Hamilton, Ruth
    Bach, Michael
    Heinrich, Sven P.
    Hoffmann, Michael B.
    Odom, J. Vernon
    McCulloch, Daphne L.
    Thompson, Dorothy A.
    DOCUMENTA OPHTHALMOLOGICA, 2021, 142 (01) : 25 - 74
  • [46] Evaluation of the “Freiburg Acuity VEP” on Commercial Equipment
    Michael Bach
    Jeffrey D. Farmer
    Documenta Ophthalmologica, 2020, 140 : 139 - 145
  • [47] Is VEP an objective method for determination of visual acuity?
    Scipioni, L
    Rispoli, E
    Gagliardi, F
    Rispoli, M
    Repossi, A
    Vingolo, EM
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2000, 41 (04) : S623 - S623
  • [48] Evaluation of Visual Acuity with Sweep VEP Method
    Cebeci, Zafer
    Yeniad, Baris
    Gezer, Acun
    TURK OFTALMOLOJI DERGISI-TURKISH JOURNAL OF OPHTHALMOLOGY, 2008, 38 (04): : 342 - 345
  • [49] Optimizing the stimulus for sweep VEP acuity estimation
    Norcia, AM
    Pettet, MW
    Candy, RC
    Skoczenski, A
    Good, WV
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 1999, 40 (04) : S820 - S820
  • [50] VEP estimation of visual acuity: a systematic review
    Ruth Hamilton
    Michael Bach
    Sven P. Heinrich
    Michael B. Hoffmann
    J. Vernon Odom
    Daphne L. McCulloch
    Dorothy A. Thompson
    Documenta Ophthalmologica, 2021, 142 : 25 - 74