COMPARISON OF DIRECT-CURRENT AND 3-PHASE AC ARC FURNACES

被引:0
|
作者
KOHLE, S
机构
来源
STAHL UND EISEN | 1994年 / 114卷 / 05期
关键词
D O I
暂无
中图分类号
TF [冶金工业];
学科分类号
0806 ;
摘要
The power of the three-phase a.c. furnace is limited in Germany according of the VDE standards to about 96 MW, which makes it possible to achieve a yearly production of 1.2 million t at a tap weight of 160 t. The power of the direct-current furnace is limited to similar levels by the voltage and length of the electric arc and by the current-carrying capacity of the graphite electrode. At a realistic assessment of the graphite consumption, clearly lower processing costs of the direct-current furnace can be achieved only through energy saving. The main advantages of the direct-current furnace are the more uniform melting of the charge and the smaller voltage fluctuations in the supply system. If the latter advantage is irrelevant because of a powerful supply system, the higher investment costs of the direct-current furnace represent, similarly to the bottom electrode, a disadvantage.
引用
收藏
页码:37 / 41
页数:5
相关论文
共 50 条
  • [31] BASIC THEORY, RECENT HISTORY AND PRELIMINARY ECONOMICS OF 3-PHASE AC PLASMA REACTOR FURNACES
    BROWN, WG
    CIM BULLETIN, 1991, 84 (950): : 149 - 152
  • [32] Modeling of a direct-current arc in a plasmatron with step electrodes
    A. F. Bublievskii
    O. I. Yas’ko
    E. I. Yurinok
    Journal of Engineering Physics and Thermophysics, 1999, 72 (5) : 927 - 934
  • [33] KINETICS OF THE SUBSTANCE EVAPORATION INTO THE PLASMA OF A DIRECT-CURRENT ARC
    KUROCHKIN, VD
    KRAVCHENKO, LF
    DOPOVIDI AKADEMII NAUK UKRAINSKOI RSR SERIYA A-FIZIKO-MATEMATICHNI TA TECHNICHNI NAUKI, 1979, (12): : 1051 - 1053
  • [34] BROADENING OF CESIUM LINES IN THE PLASMA OF A DIRECT-CURRENT ARC
    GOLDFARB, VM
    ILYINA, EV
    OPTIKA I SPEKTROSKOPIYA, 1964, 17 (02): : 302 - 304
  • [35] Gain Fault Detection Method for 3-phase AC Current Sensors
    Tanaka H.
    Akita Y.
    IEEJ Transactions on Industry Applications, 2023, 143 (06) : 455 - 463
  • [36] The no-load performance of 3-phase transformer bank under direct-current bias based on the 3D transient analysis
    Yao, YY
    Xie, DX
    Bai, BD
    Zeng, LS
    ICEMS'2001: PROCEEDINGS OF THE FIFTH INTERNATIONAL CONFERENCE ON ELECTRICAL MACHINES AND SYSTEMS, VOLS I AND II, 2001, : 281 - 284
  • [37] An Efficient Simulation Method for Current and Power distribution in 3-Phase Electrical Smelting Furnaces
    Halvorsen, S. A.
    Olsen, H. A. H.
    Fromreide, M.
    IFAC PAPERSONLINE, 2016, 49 (20): : 167 - 172
  • [38] PRESSURE OF POWERFUL 3-PHASE ARC
    STOLBOV, VI
    IEVLEV, VA
    KLIMAKHIN, ON
    AUTOMATIC WELDING USSR, 1974, 27 (08): : 9 - 12
  • [39] Toward a Simplified Arc Impingement Model in a Direct-Current Electric Arc Furnace
    Al-Nasser, Mohamad
    Kharicha, Abdellah
    Barati, Hadi
    Pichler, Christoph
    Hackl, Gernot
    Gruber, Markus
    Ishmurzin, Anton
    Redl, Christian
    Wu, Menghuai
    Ludwig, Andreas
    METALS, 2021, 11 (09)
  • [40] THE DIRECT-CURRENT ARC FURNACE, A NEW TYPE OF MELTING UNIT
    ESSMANN, H
    GRUNBERG, D
    STAHL UND EISEN, 1982, 102 (21): : I16 - I17