THE DEVELOPMENT OF NEUTRON DOSIMETER USING CR-39 DETECTOR

被引:1
|
作者
ELKHATIB, AM [1 ]
ABOUELKHIER, AA [1 ]
FAWZY, MA [1 ]
ELCHENNAWI, SE [1 ]
机构
[1] KING ABDULAZIZ UNIV,FAC MED,JEDDAH,SAUDI ARABIA
来源
关键词
CHEMICAL ETCHING; ELECTROCHEMICAL ETCHING; CR-39 TRACK DETECTOR; CONVERTER; RADIATOR; DETECTOR SENSITIVITY; THERMAL-; INTERMEDIATE-; FAST-NEUTRON DOSIMETER;
D O I
10.1080/10420159408221054
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
The local demands for an improved neutron dosimeter have been grown in recent years. This work outlines a design for a dosimeter to measure incident neutron doses with any energy (thermal, intermediate and fast). Moreover this study presents the effect of radiators and converters on the sensitivity of chemically etched CR-39 detectors, as well as the sensitivity of electrochemically etched detectors at different frequencies and applied voltages.
引用
收藏
页码:319 / 325
页数:7
相关论文
共 50 条
  • [41] NEUTRON SENSITIVITY OF CR-39 SSNTD
    BIRKHOLZ, W
    WINKLER, C
    BAUMBACH, H
    NUCLEAR TRACKS AND RADIATION MEASUREMENTS, 1991, 19 (1-4): : 453 - 456
  • [42] FAST-NEUTRON SPECTROMETRY BASED ON PROTON DETECTION IN CR-39 DETECTOR
    DAJKO, G
    SOMOGYI, G
    NUCLEAR TRACKS AND RADIATION MEASUREMENTS, 1986, 12 (1-6): : 607 - 610
  • [43] FAST NEUTRON SPECTROMETRY BASED ON PROTON DETECTION IN CR-39 DETECTOR.
    Dajko, G.
    Somogyi, G.
    Nuclear tracks, 1985, 12 (1-6): : 607 - 610
  • [44] A simulation of neutron interaction from Am-Be source with the CR-39 detector
    Milenkovic, Biljana
    Nikezic, Dragoslav
    Stevanovic, Nenad
    RADIATION MEASUREMENTS, 2010, 45 (10) : 1338 - 1341
  • [45] A REVIEW OF THE USE OF CR-39 TRACK DETECTOR IN PERSONNEL NEUTRON DOSIMETRY AND SPECTROMETRY
    MATIULLAH
    AHMAD, N
    DURRANI, SA
    KUDO, K
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 1990, 51 (01): : 76 - 84
  • [46] Improvement of neutron detection efficiency with high sensitive CR-39 track detector
    Oda, K
    Ichijo, H
    Miyawaki, N
    Yamauchi, T
    Nakane, Y
    RADIATION MEASUREMENTS, 2001, 34 (1-6) : 171 - 175
  • [47] Registration of alpha particles using CR-39 nuclear detector
    Abdalla, Ayman M.
    Al-Naggar, Tayseer I.
    Alhandhal, Rayah H.
    Albargi, Hasan B.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2022, 1042
  • [48] MAKROFOL AND CR-39 RECOIL TRACK ETCH DETECTORS AS A SUPPLEMENT OF A UNIVERSAL ALBEDO NEUTRON DOSIMETER
    PIESCH, E
    JASIAK, J
    URBAN, M
    NUCLEAR TRACKS AND RADIATION MEASUREMENTS, 1984, 8 (1-4): : 323 - 326
  • [49] Characteristics of the solid state nuclear detector CR-39 for neutron radiography purposes
    Pugliesi, R
    Pereira, MAS
    de Moraes, MAPV
    de Menezes, MO
    APPLIED RADIATION AND ISOTOPES, 1999, 50 (02) : 375 - 380
  • [50] AN IMPROVED CR-39 DETECTOR MATERIAL WITH LOW BACKGROUND FOR ALPHA AND NEUTRON MEASUREMENTS
    GUHR, A
    SARENIO, O
    LASSARY, D
    RADIATION PROTECTION DOSIMETRY, 1990, 34 (1-4) : 35 - 38