Corneal spherical aberration and its impact on choosing an intraocular lens for cataract surgery

被引:12
|
作者
Al-Sayyari, Tarfah M. [1 ]
Fawzy, Samah M. [2 ]
Al-Saleh, Ahmed A. [3 ]
机构
[1] King Saud Univ, POB 231818, Riyadh 11321, Saudi Arabia
[2] Ain Shams Univ, Ophthalmol Dept, Cairo, Egypt
[3] AlHokama Eye Specialist Ctr, Riyadh, Saudi Arabia
关键词
Spherical aberration; Z(4,0); Z(6,0); IOL; Cataract; Corneal aberration; Higher order aberration; Intraocular lens;
D O I
10.1016/j.sjopt.2014.06.005
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To analyze the post operative results of targeting zero spherical aberration by selecting the best-fit aspheric intraocular lens (IOL), based on preoperative corneal spherical aberration of patients with phacoemulsification surgery. Setting: AlHokama Eye Specialist Center, Riyadh, Saudi Arabia. Period: From the 1st of October 2012 until the 10th of April 2013. Methods: Fifty-three eyes, were subjected to phacoemulsification cataract surgery and divided into two groups, 34 eyes were implanted with aspheric IOLs based on their corneal spherical aberration targeting post operative zero total spherical aberration, whereas 19 eyes were implanted with neutral aspheric IOLs regardless of their corneal spherical aberrations (CSAs). As a pre and post routine examination, patients underwent: slit lamp testing, intraocular pressure (IOP) measuring, fundus examination, best spectacle corrected visual acuity (BSCVA), manifest refraction, pupillometry, axial length, contrast sensitivity, and corneal aberration measurement using Pentacam HR (OCULUS, Germany) at the 6-mm optical zone. Post operatively, visual function questionnaire (VF-14) was asked to all patients. Results: Fifty-three eyes of 45 patients, whose age ranged from 45 to 90 years old, were available for analysis, the selected group was implanted with: Tecnis ZA9003 or ZCB00 (Abbott Medical Optics) IOLs in 17 eyes with corneal spherical aberration of more than 0.27 mu m, AcrySof IQ SN60WF (Alcon Laboratories Inc.) IOLs were implanted in 4 eyes with CSA = (0.2-0.27) mu m, and Rayner 970C, 920H or 620H IOLs with spherical aberration (SA) = 0 in 13 eyes with CSA less than 0.20 mu m. The other group of 19 eyes was implanted with aspheric IOLs that have zero spherical aberration (Rayner 970C or 920H) regardless of their CSA. Root mean square (RMS) of total corneal aberration positively correlates to the pupil diameter (P = 0.0031, r = 0.3989). A low negative correlation was found between the corneal spherical aberration of the fourth ordered (Z40) and the axial length (r = -0.2009, P = 0.1492). There was no significant difference between the selected and non-selected group in contrast sensitivity, best spectacle corrected visual acuity, and visual satisfaction (P = 0.5316, P = 0.3919, P = 0.7667). Conclusion: Customized selection of aspheric IOLs based on the eyes' corneal spherical aberration has no significant importance comparing their results with the non-selected group.
引用
收藏
页码:274 / 280
页数:7
相关论文
共 50 条
  • [21] Importance of corneal spherical aberration in pupil area for multifocal intraocular lens selection: a case report
    Kim, Soojin
    Choi, Yoonseong
    Nam, Deokjo
    Choi, Sung-Ho
    BMC OPHTHALMOLOGY, 2025, 25 (01)
  • [22] Effect of cataract incision type on corneal spherical aberration
    Li, Xiaochun
    Cao, Xiaoguang
    Hou, Xian-Ru
    Yuan, Li
    Yu, Ying-Ying
    Bao, Yong-Zhen
    MEDICINE, 2022, 101 (35) : E30292
  • [23] Influence of corneal asphericity on the refractive outcome of intraocular lens implantation in cataract surgery
    Savini, Giacomo
    Hoffer, Kenneth J.
    Barboni, Piero
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2015, 41 (04): : 785 - 789
  • [24] Cataract surgery with toric intraocular lens implantation in patients with high corneal astigmatism
    Visser, Nienke
    Ruiz-Mesa, Ramon
    Pastor, Francisco
    Bauer, Noel J. C.
    Nuijts, Rudy M. M. A.
    Montes-Mico, Robert
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2011, 37 (08): : 1403 - 1410
  • [25] Transitional conic toric intraocular lens for the management of corneal astigmatism in cataract surgery
    Bandeira, Francisco
    Morral, Merce
    Elies, Daniel
    Eguiza, Sergio
    Souki, Spyridoula
    Manero, Felicidad
    Gueell, Jose L.
    CLINICAL OPHTHALMOLOGY, 2018, 12 : 1071 - 1079
  • [26] Scheimpflug Corneal Power Measurements for Intraocular Lens Power Calculation in Cataract Surgery
    Saad, Elie
    Shammas, Maya C.
    Shammas, H. John
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 2013, 156 (03) : 460 - 467
  • [27] Intraocular lens employed for cataract surgery
    Roszkowska, A. M.
    Torrisi, L.
    PLASMA PHYSICS BY LASER AND APPLICATIONS 2013 CONFERENCE (PPLA2013), 2014, 508
  • [28] Personalized correction of spherical aberration in cataract surgery
    Beiko, George H. H.
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2007, 33 (08): : 1455 - 1460
  • [29] High order aberration and straylight evaluation after cataract surgery with implantation of an aspheric,aberration correcting monofocal intraocular lens
    Florian T A Kretz
    Tamer Tandogan
    Ramin Khoramnia
    Gerd U Auffarth
    International Journal of Ophthalmology, 2015, 8 (04) : 736 - 741
  • [30] High order aberration and straylight evaluation after cataract surgery with implantation of an aspheric, aberration correcting monofocal intraocular lens
    Kretz, Florian T. A.
    Tandogan, Tamer
    Khoramnia, Ramin
    Auffarth, Gerd U.
    INTERNATIONAL JOURNAL OF OPHTHALMOLOGY, 2015, 8 (04) : 736 - 741