MODEL FOR AMPEROMETRIC ENZYME ELECTRODE OBTAINED THROUGH DIGITAL-SIMULATION AND APPLIED TO IMMOBILIZED GLUCOSE OXIDASE SYSTEM

被引:270
|
作者
MELL, LD [1 ]
MALOY, JT [1 ]
机构
[1] W VIRGINIA UNIV,DEPT CHEM,MORGANTOWN,WV 26506
关键词
D O I
10.1021/ac60352a006
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
引用
收藏
页码:299 / 307
页数:9
相关论文
共 50 条
  • [21] QUINONE-MEDIATED GLUCOSE-OXIDASE ELECTRODE WITH THE ENZYME IMMOBILIZED IN POLYPYRROLE
    JANDA, P
    WEBER, J
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1991, 300 (1-2) : 119 - 127
  • [22] X-ray Microanalysis of the activity of immobilized glucose oxidase on enzyme electrode
    Li, T
    Yao, ZH
    Qiu, MD
    An, W
    Shi, DG
    SPECTROSCOPY AND SPECTRAL ANALYSIS, 2005, 25 (07) : 1151 - 1154
  • [23] X-ray microanalysis of the activity of immobilized glucose oxidase on enzyme electrode
    Li, Tong
    Yao, Zi-Hua
    Qiu, Man-De
    An, Wei
    Shi, Da-Gang
    Guang Pu Xue Yu Guang Pu Fen Xi/Spectroscopy and Spectral Analysis, 2005, 25 (07): : 1151 - 1154
  • [24] AN AMPEROMETRIC GLUCOSE SENSOR MADE BY MODIFICATION OF A GRAPHITE ELECTRODE SURFACE WITH IMMOBILIZED GLUCOSE-OXIDASE AND ADSORBED MEDIATOR
    JONSSON, G
    GORTON, L
    BIOSENSORS, 1985, 1 (04) : 355 - 368
  • [25] Amperometric glucose enzyme electrode by immobilizing glucose oxidase in multilayers on self-assembled monolayers surface
    Hou, SF
    Yang, KS
    Fang, HQ
    Chen, HY
    TALANTA, 1998, 47 (03) : 561 - 567
  • [26] AMPEROMETRIC ENZYME ELECTRODE FOR DETERMINATION OF GLUCOSE BASED ON THIN-LAYER SPECTROELECTROCHEMISTRY OF GLUCOSE-OXIDASE
    DURLIAT, H
    COMTAT, M
    ANALYTICAL CHEMISTRY, 1984, 56 (02) : 148 - 152
  • [27] AMPEROMETRIC ENZYME ELECTRODE SYSTEM FOR THE FLOW-INJECTION ANALYSIS OF GLUCOSE
    MOODY, GJ
    SANGHERA, GS
    THOMAS, JDR
    ANALYST, 1986, 111 (06) : 605 - 609
  • [28] A biosensor system for chlorophenols using chloroperoxidase and a glucose oxidase based amperometric electrode
    Saby, C
    Luong, JHT
    ELECTROANALYSIS, 1998, 10 (01) : 7 - 11
  • [29] Amperometric enzyme electrode for free cholesterol determination prepared with cholesterol oxidase immobilized in poly(vinylferrocenium) film
    Ozer, B. Cem
    Ozyoruk, Haluk
    Celebi, Serdar S.
    Yildiz, Atilla
    ENZYME AND MICROBIAL TECHNOLOGY, 2007, 40 (02) : 262 - 265
  • [30] A Biosensor System for Chlorophenols Using Chloroperoxidase and a Glucose Oxidase Based Amperometric Electrode
    Saby, C.
    Luong, J. H. T.
    Electroanalysis, 10 (01):