EXERCISE PERFORMANCE WITH SINGLE CHAMBER RATE-RESPONSIVE PACING IN CONGENITAL HEART-DEFECTS AFTER OPERATION

被引:7
|
作者
PARIDON, SM [1 ]
KARPAWICH, PP [1 ]
PINSKY, WW [1 ]
机构
[1] WAYNE STATE UNIV,SCH MED,DETROIT,MI 48201
来源
AMERICAN JOURNAL OF CARDIOLOGY | 1991年 / 68卷 / 11期
关键词
D O I
10.1016/0002-9149(91)90201-U
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The use of various types of rate-responsive pacing systems (AAI-R, VVI-R) in anatomically normal hearts has resulted in improved exercise performance. This has been measured as improved work rate, maximal oxygen consumption, and oxygen consumption at which ventilatory anaerobic threshold is achieved. The usefulness of rate-responsive pacing in patients with congenital heart defects has not been extensively studied.1-3 Most patients with congenital heart defects are postoperative patients with either surgical atrioventricular block or sinus node dysfunction.4,5 The underlying structural cardiac defects are often complex and may contribute to impaired ventricular function. How these abnormalities affect physiologic cardiopulmonary response with single chamber rate-responsive pacing is unknown. We compared the exercise responses of patients with congenital heart defects using an implanted motion-sensing rate-responsive single chamber pacing system. This study was performed to evaluate potential efficacy of variable over fixed rate single chamber pacing in these patients. © 1991.
引用
收藏
页码:1231 / 1233
页数:3
相关论文
共 50 条
  • [21] DUAL CHAMBER RATE-RESPONSIVE PACING - FEASIBILITY STUDIES IN DDD PATIENTS USING CONTINUOUS PACEMAKER REPROGRAMMING
    REYNOLDS, D
    GOLI, V
    BENNETT, T
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1987, 10 (02): : 419 - 419
  • [22] DUAL CHAMBER RATE-RESPONSIVE PACING - FEASIBILITY STUDIES IN DDD PATIENTS USING CONTINUOUS PACEMAKER REPROGRAMMING
    REYNOLDS, D
    GOLI, V
    BENNETT, T
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1987, 10 (03): : 733 - 733
  • [23] AN IMPROVED SINGLE-LEAD ATRIAL-SYNCHRONOUS VENTRICULAR PACING SYSTEM FOR NATURAL, RATE-RESPONSIVE PACING
    GOLDREYER, BN
    BROWNLEE, RR
    SHIMMELGOLDEN, JB
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1987, 10 (05): : 1212 - 1212
  • [24] FONTAN OPERATION FOR COMPLEX CONGENITAL HEART-DEFECTS OTHER THAN TRICUSPID ATRESIA
    HELGASON, H
    MAYER, JE
    SANDERS, SP
    LANG, P
    JONAS, RA
    CASTANEDA, AR
    AMERICAN HEART JOURNAL, 1985, 110 (03) : 705 - 705
  • [25] RATE-RESPONSIVE PACING BY MEANS OF ACTIVITY SENSING VERSUS SINGLE RATE VENTRICULAR PACING - A DOUBLE-BLIND CROSSOVER STUDY
    SMEDGARD, P
    KRISTENSSON, BE
    KRUSE, I
    RYDEN, L
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1987, 10 (04): : 902 - 915
  • [26] SINGLE VERSUS DOUBLE CHAMBER RATE RESPONSIVE CARDIAC PACING - COMPARISON BY CARDIOPULMONARY NONINVASIVE EXERCISE TESTING
    VOGT, P
    GOY, JJ
    KUHN, M
    LEUENBERGER, P
    KAPPENBERGER, L
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1988, 11 (11): : 1896 - 1901
  • [27] RATE-RESPONSIVE PACING USING DYNAMIC RIGHT VENTRICULAR PRESSURE IN HEART-BLOCKED DOGS
    BENNETT, TD
    BAUDINO, M
    BORNZIN, G
    ANDERSON, K
    OLSON, W
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1985, 5 (02) : 393 - 393
  • [28] Rate-responsive pacing in patients with heart failure:: long-term results of a randomized study
    Naegele, Herbert
    Roediger, Wilfried
    Castel, Maria Angeles
    EUROPACE, 2008, 10 (10): : 1182 - 1188
  • [29] PREGNANCY OUTCOME AFTER SURGICAL REPAIR CONGENITAL HEART-DEFECTS (CHD)
    MORRIS, CD
    MENASHE, VD
    CIRCULATION, 1985, 72 (04) : 116 - 116
  • [30] RATE-RESPONSIVE PACING AS COMPARED TO FIXED-RATE VVI PACING IN PATIENTS AFTER ABLATION OF THE ATRIOVENTRICULAR-CONDUCTION SYSTEM
    TRAPPE, HJ
    KLEIN, H
    FRANK, G
    LICHTLEN, PR
    EUROPEAN HEART JOURNAL, 1988, 9 (06) : 642 - 648