Biomechanical comparison of a novel C1 posterior U-construct with four other techniques in a C1-C2 fixation model

被引:0
|
作者
Herzog, Joshua P. [1 ,4 ]
Zarkadis, Nicholas J. [2 ,4 ]
Prabhakar, Gautham [3 ,4 ]
Kusnezov, Nicholas A. [2 ,4 ]
机构
[1] Massachusetts Gen Hosp, Orthopaed Spine Ctr, Boston, MA 02114 USA
[2] William Beaumont Army Med Ctr, Dept Orthopaed Surg & Rehabil, El Paso, TX 79920 USA
[3] Texas Tech Univ, Hlth Sci Ctr El Paso, Paul L Foster Sch Med, El Paso, TX USA
[4] 5005 N Piedras St, El Paso, TX 79920 USA
关键词
Biomechanical stability; Cervical fixation; Atlantoaxial; Brooks wire;
D O I
10.1016/j.jor.2018.05.010
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: Compare the biomechanical stability of a novel "U" posterior cervical fixation construct to four other posterior cervical atlantoaxial fixation constructs. Methods: Eight fresh frozen human cadaver spines were tested after a simulated odontoid fracture, and following stabilization with each construct. Results: All constructs significantly decreased flexion-extension and axial rotation compared to the destabilized spine. The U construct provided significantly more axial stability than the Brooks wire technique. Conclusion: The novel U construct demonstrated comparable biomechanical stability to the existing constructs in all three planes of motion with the exception of axial rotation, in which it was inferior to TAS.
引用
收藏
页码:741 / 745
页数:5
相关论文
共 50 条
  • [31] Posterior C1-C2 screw-rod fixation and autograft fusion for the treatment of os odontoideum with C1-C2 instability
    Huang, Da-Geng
    Wang, Tao
    Hao, Ding-Jun
    He, Bao-Rong
    Liu, Tuan-Jiang
    Ma, Xiao-Wen
    Yu, Cheng-Cheng
    Feng, Hang
    Zhao, Song-Chum
    Hui, Hua
    CLINICAL NEUROLOGY AND NEUROSURGERY, 2017, 163 : 71 - 75
  • [32] C1-C2 Posterior Fixation: Are 4 Screws Better Than 2?
    Vergara, Pierluigi
    Bal, Jarnail Singh
    Casey, Adrian Thomas Hickman
    Crockard, Hugh Alan
    Choi, David
    NEUROSURGERY, 2012, 71 : 86 - 95
  • [33] Biomechanical comparison of C1-C2 posterior fixations - Cable, graft, and screw combinations - Point of view
    Cooper, PR
    SPINE, 1998, 23 (18) : 1955 - 1956
  • [34] Posterior C1-C2 transarticular screw fixation for atlantoaxial arthrodesis - Comment
    McCormick, PC
    NEUROSURGERY, 1998, 43 (02) : 280 - 280
  • [35] Biomechanical comparison of the pullout strengths of C1 lateral mass screws and C1 posterior arch screws
    Zarro, Christopher M.
    Ludwig, Steven C.
    Hsieh, Adam H.
    Seal, Charles N.
    Gelb, Daniel E.
    SPINE JOURNAL, 2013, 13 (12): : 1892 - 1896
  • [36] Posterior C1-C2 transarticular screw fixation for atlantoaxial arthrodesis - Reply
    Dickman, CA
    Sonntag, VKH
    NEUROSURGERY, 1999, 44 (03) : 688 - 689
  • [37] Posterior C1-C2 transarticular screw fixation for instability of the C0-C2 complex
    Martín-Ferrer, S
    Rimbau, J
    Joly, MC
    Teruel, J
    Pont, J
    NEUROCIRUGIA, 2000, 11 (01): : 43 - 49
  • [38] Atlantoaxial fusion: a biomechanical analysis of two C1-C2 fusion techniques
    Claybrooks, Roderick
    Kayanja, Mark
    Milks, Ryan
    Benzel, Edward
    SPINE JOURNAL, 2007, 7 (06): : 682 - 688
  • [39] Odontoid plate fixation without C1-C2 arthrodesis: Biomechanical testing of a novel surgical technique and comparison to the conventional screw fixation procedure
    Platzer, Patrick
    Eipeldauer, Stefan
    Vecsei, Vilmos
    CLINICAL BIOMECHANICS, 2010, 25 (07) : 623 - 627
  • [40] C1-C2 Posterior Fixation: Are 4 Screws Better Than 2? COMMENTS
    Sonntag, Volker K. H.
    Harrop, James S.
    NEUROSURGERY, 2012, 71 : 95 - 95