Spirometers

被引:0
|
作者
de Jongh, F. [1 ]
机构
[1] Poli 12 Medisch Spectrum Twente, Lungfunct Lab, Haaksbergerstr 55, NL-7500 KA Enschede, Netherlands
关键词
D O I
暂无
中图分类号
R56 [呼吸系及胸部疾病];
学科分类号
摘要
There are many spirometers on the market. They can be divided roughly into a group that primarily measures volume and a group that primarily measures flow. Quality control and calibration should be performed on a regular basis to ensure that a device (still) functions appropriately. The types have different characteristics and are optimal for different circumstances (from a simple peak-flow meter to monitor asthma at home to an ultrasonic device to measure a patient in a pulmonary function lab). In this article, the characteristics of the currently available spirometers are discussed, as well as the requirements they should fulfil.
引用
收藏
页码:251 / 254
页数:4
相关论文
共 50 条
  • [21] ELECTRONICAL SPIROMETERS IN CLINICAL AND PRACTICAL USE
    KELLER, R
    SCHWEIZERISCHE RUNDSCHAU FUR MEDIZIN PRAXIS, 1974, 63 (43): : 1273 - 1275
  • [22] EVALUATION OF 2 PORTABLE ELECTRONIC SPIROMETERS
    TSCHOPP, JM
    ROULIN, JP
    JUILLAND, A
    ERNE, R
    SCHWEIZERISCHE MEDIZINISCHE WOCHENSCHRIFT, 1988, 118 (38) : 1382 - 1385
  • [23] EVALUATION OF 3 SPIROMETERS ON HEALTHY CHILDREN
    DALEN, G
    KJELLMAN, B
    ACTA PAEDIATRICA SCANDINAVICA, 1978, 67 (06): : 741 - 744
  • [24] Longitudinal validity of spirometers -: a challenge in longitudinal studies
    Künzli, N
    Kuna-Dibbert, B
    Keidel, D
    Keller, R
    Brändli, O
    Schindler, C
    Schweinzer, KM
    Leuenberger, P
    Ackermann-Liebrich, U
    SWISS MEDICAL WEEKLY, 2005, 135 (33-34) : 503 - 508
  • [25] Accuracy of spirometers used in primary care
    Hegewald, Matthew
    Gallo, Heather
    Linares, Olinto
    Jensen, Robert
    Morris, Alan
    EUROPEAN RESPIRATORY JOURNAL, 2015, 46
  • [26] EVALUATING COMMERCIALLY AVAILABLE SPIROMETERS - REPLY
    GARDNER, RM
    HANKINSON, JL
    WEST, BJ
    AMERICAN REVIEW OF RESPIRATORY DISEASE, 1980, 122 (01): : 173 - 175
  • [27] ACCURACY OF SPIROMETERS USED IN INTUBATED PATIENTS
    RASSULO, J
    MAKE, B
    CHEST, 1982, 82 (02) : 250 - 250
  • [28] SPIROMETERS AS A VECTOR FOR MYCOBACTERIUM-TUBERCULOSIS (MTB)
    BLEVINS, W
    FIELDS, S
    MURPHY, D
    RIVERA, M
    NICOTRA, B
    CHEST, 1986, 89 (06) : S530 - S530
  • [29] Considerations in the use of different spirometers in epidemiological studies
    Edith B. Milanzi
    Gerard H. Koppelman
    Marieke Oldenwening
    Sonja Augustijn
    Bernadette Aalders-de Ruijter
    Martijn Farenhorst
    Judith M. Vonk
    Marjan Tewis
    Bert Brunekreef
    Ulrike Gehring
    Environmental Health, 18
  • [30] Fusion of Basic Spirometers for Anesthetic Gas Concentration Sensing
    Kolbay, Patrick
    Orr, Joseph
    Kuck, Kai
    ANESTHESIA AND ANALGESIA, 2019, 128