SELF-SUPPORTING CYLINDRICAL MULTIWIRE PROPORTIONAL CHAMBERS WITH TWO-DIMENSIONAL READ-OUT

被引:5
|
作者
KOBAYASHI, M
KUROKAWA, SI
FUJITANI, T
NAGASHIMA, Y
OMORI, T
SUGIMOTO, S
YAMAGUCHI, Y
IWAHORI, JI
YOSHIDA, H
TAKEUTCHI, F
机构
[1] KYOTO SANGYO UNIV,KITA KU,KYOTO 603,JAPAN
[2] OSAKA UNIV,DEPT PHYS,TOYONAKA,OSAKA 560,JAPAN
[3] FUKUOKA DENT COLL,FAC ENGN,FUKUOKA 814,JAPAN
关键词
NUCLEAR INSTRUMENTATION - Readout Systems - PHYSICS - High Energy;
D O I
10.1016/0168-9002(86)90257-3
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Cylindrical MWPCs have been constructed with anode diameters of 240-430 mm and a length of 750 mm. Cathode strips run helically with 38 degree -61 degree to the anode wires, and the induced charges were read out by ADC. Both the anode and the cathode efficiency were well above 99%. The resolution ( sigma ) for the longitudinal position of the avalanche was 0. 6 mm by the center of gravity method, if the cathode was read out per 12 mm width by summing two adjacent cathode strips.
引用
收藏
页码:51 / 58
页数:8
相关论文
共 48 条
  • [1] SOME READ-OUT SYSTEMS FOR PROPORTIONAL MULTIWIRE CHAMBERS
    CHARPAK, G
    BOUCLIER, R
    BRESSANI, T
    FAVIER, J
    ZUPANCIC, C
    NUCLEAR INSTRUMENTS & METHODS, 1968, 65 (02): : 217 - &
  • [2] HIGH-VOLTAGE READ-OUT FOR MULTIWIRE PROPORTIONAL CHAMBERS
    FISCHER, G
    PLCH, J
    NUCLEAR INSTRUMENTS & METHODS, 1972, 100 (03): : 515 - &
  • [3] LARGE RADIUS SELF-SUPPORTING CYLINDRICAL MULTIWIRE PROPORTIONAL CHAMBERS TO BE USED AT THE ASTERIX EXPERIMENT AT LEAR
    AHMAD, S
    BIZOT, JC
    DELCOURT, B
    JEANJEAN, J
    JEANJEAN, M
    NGUYENNGOC, H
    WODRICH, WR
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH, 1983, 217 (1-2): : 169 - 172
  • [4] A STACK OF TWO-DIMENSIONAL MULTIWIRE PROPORTIONAL CHAMBERS AS PART OF AN ELECTROMAGNETIC CALORIMETER
    MOUELLIC, B
    SANTIARD, JC
    PIA, MG
    CHEMARIN, M
    FAY, J
    LARSEN, B
    BROM, JM
    ESCOUBES, B
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1987, 262 (2-3): : 269 - 283
  • [5] A STUDY OF THE DETECTION ACCURACY OF PROPORTIONAL CHAMBERS WITH CATHODE READ-OUT
    BARABASH, LS
    BARANOV, AM
    BONDARENKO, GB
    CHALYSHEV, VV
    DOLGOSHEIN, BA
    GOLUTVIN, IA
    KANTSEROV, VA
    KARPUKHIN, AV
    KHABAROV, VS
    KOMOGOROVA, LV
    KONOVALOV, VP
    KONOVALOVA, TN
    NEVSKY, PL
    POPOV, AA
    PUGACHEVICH, VP
    SUMAROKOV, AV
    YATSUNENKO, YA
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1985, 236 (02): : 271 - 273
  • [6] STACK OF TWO-DIMENSIONAL MULTIWIRE PROPORTIONAL CHAMBERS AS PART OF AN ELECTROMAGNETIC CALORIMETER.
    Moueellic, B.
    Santiard, J.C.
    Pia, M.G.
    Chermarin, M.
    Fay, J.
    Larsen, B.
    Brom, J.M.
    Escoubes, B.
    Nuclear instruments and methods in physics research, 1987, A262 (2-3): : 269 - 283
  • [7] MULTI-DELAY LINE CATHODE READ OUT OF MULTIWIRE PROPORTIONAL CHAMBERS
    CHAMINADE, R
    LEGRELE, C
    LUGOL, JC
    SILLON, Y
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1979, 26 (01) : 203 - 208
  • [8] A large area MicroGap chamber with two-dimensional read-out
    Angelini, F
    Bellazzini, R
    Brez, A
    Massai, MM
    Raffo, R
    Spandre, G
    Spezziga, M
    Bozzo, M
    Caner, A
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1996, 43 (03) : 1237 - 1242
  • [9] Data recovery in two-dimensional read-out of optical tape
    Simone, AD
    Mitkas, PA
    Betzos, GA
    ODS - 1997 OPTICAL DATA STORAGE TOPICAL MEETING, CONFERENCE DIGEST, 1997, : 58 - 59
  • [10] Data recovery during two-dimensional read-out of optical tape
    Simone, AD
    Mitkas, PA
    Betzos, GA
    OPTICAL DATA STORAGE '97, 1997, 3109 : 116 - 125