LIMITATIONS OF FOREHEAD PULSE OXIMETRY

被引:18
|
作者
JORGENSEN, JS [1 ]
SCHMID, ER [1 ]
KONIG, V [1 ]
FAISST, K [1 ]
HUCH, A [1 ]
HUCH, R [1 ]
机构
[1] UNIV ZURICH HOSP,DEPT OBSTET,PERINATAL PHYSIOL UNIT,CH-8091 ZURICH,SWITZERLAND
来源
JOURNAL OF CLINICAL MONITORING | 1995年 / 11卷 / 04期
关键词
MONITORING; PULSE OXIMETRY; MEASUREMENT TECHNIQUES;
D O I
10.1007/BF01617520
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
During initial clinical tests to calibrate our reflectance pulse oximetry system, we observed serious physiologic limitations to the use of pulse oximetry in the forehead region. We present a case of simultaneous reflectance and transmission mode pulse oximetry monitoring in a child undergoing cardiac surgery for congenital cyanotic heart disease with a large intracardiac shunt. During general anesthesia, when the patient was endotracheally intubated and mechanically ventilated, the transmission mode saturation agreed well with arterial oxygen saturation measurements; but, our reflectance pulse oximeter, with the sensor applied to the forehead, displayed spuriously lower (-18%) oxygen saturations. Before and after anesthesia and surgery, there was fine agreement between reflectance and transmission mode saturation values. We suggest that the difference was caused by vasodilatation and pooling of venous blood due to compromised venous return to the heart, and a combination of arterial and venous pulsations in the forehead region. This means that the reflectance pulse oximeter measured a mixed arterial-venous oxygen saturation.
引用
收藏
页码:253 / 256
页数:4
相关论文
共 50 条
  • [31] Limitations of pulse oximetry in neonates: a double-blinded study; Protocol presentation
    Guleria, A.
    Koh, A.
    BRITISH JOURNAL OF ANAESTHESIA, 2015, 115 (06) : E950 - E950
  • [32] Pulse oximetry: Understanding its basic principles facilitates appreciation of its limitations
    Chan, Edward D.
    Chan, Michael M.
    Chan, Mallory M.
    RESPIRATORY MEDICINE, 2013, 107 (06) : 789 - 799
  • [33] Pulse oximetry and high-dose vasopressors: a comparison between forehead reflectance and finger transmission sensors
    Nesseler, Nicolas
    Frenel, Jean-Vincent
    Launey, Yoann
    Morcet, Jeff
    Malledant, Yannick
    Seguin, Philippe
    INTENSIVE CARE MEDICINE, 2012, 38 (10) : 1718 - 1722
  • [34] Forehead oximetry: Another (little) brick in the wall
    Bambi, Stefano
    Orlandi, Irene
    Lumini, Enrico
    Becattini, Giovanni
    HEART & LUNG, 2008, 37 (01): : 76 - 76
  • [35] Everything About Pulse Oximetry-Part 1: History, Principles, Advantages, Limitations, Inaccuracies, Cost Analysis, the Level of Knowledge About Pulse Oximeter Among Clinicians, and Pulse Oximetry Versus Tissue Oximetry
    Tekin, Kemal
    Karadogan, Muhammed
    Gunaydin, Secil
    Kismet, Kemal
    JOURNAL OF INTENSIVE CARE MEDICINE, 2023, 38 (09) : 775 - 784
  • [36] PULSE OXIMETRY
    TREMPER, KK
    CHEST, 1989, 95 (04) : 713 - 715
  • [37] Pulse oximetry
    Jubran, A
    INTENSIVE CARE MEDICINE, 2004, 30 (11) : 2017 - 2020
  • [38] Pulse Oximetry
    Nasr, Viviane G.
    DiNardo, James A.
    PEDIATRICS IN REVIEW, 2019, 40 (11) : 605 - 608
  • [39] Pulse oximetry
    Amal Jubran
    Intensive Care Medicine, 2004, 30 : 2017 - 2020
  • [40] PULSE OXIMETRY
    ROLLY, G
    VERSICHELEN, L
    ANNALES FRANCAISES D ANESTHESIE ET DE REANIMATION, 1989, 8 (03): : 171 - 174