MAGNETIC-RESONANCE-IMAGING OF FISTULA-IN-ANO - TECHNIQUE, INTERPRETATION AND ACCURACY

被引:93
|
作者
BARKER, PG
LUNNISS, PJ
ARMSTRONG, P
REZNEK, RH
COTTAM, K
PHILLIPS, RK
机构
[1] ST BARTHOLOMEWS HOSP,DEPT SURG,LONDON EC1A 7BE,ENGLAND
[2] ST MARKS HOSP,LONDON,ENGLAND
[3] LONDON CLIN SCANNING SERV,LONDON,ENGLAND
关键词
D O I
10.1016/S0009-9260(05)82906-X
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The aim of this study was to document the appearances of fistula-in-ano on magnetic resonance imaging (MRI) and to prospectively evaluate the accuracy of MRI in the pre-operative assessment of anal fistulae. Patients with a clinical diagnosis of fistula-in-ano and awaiting surgery (n=35) were examined with MRI. The fistulous tracks with their secondary extensions and abscesses are readily seen as low signal on T1-weighted images and high signal areas on STIR images. In order to determine the accuracy of the MRI interpretations, an experienced coloproctologist operated on all 35 patients without the knowledge of the scan interpretations and the findings at surgery were compared with the MRI scan interpretations. Concordance rates between MRI and operative findings were 86% for presence and course of the primary track, 91% for the presence and site of secondary extensions or abscesses and 97% for the presence of horse-shoeing. Although operative findings by an experienced coloproctologist were taken as the gold standard, we have shown that in 9% of our study group, failure of healing was related to pathology missed at surgery which had been documented on pre-operative MRI. It is probable, therefore, that the accuracy of MRI is higher than the figures quoted above, MRI is advocated as the imaging method of choice in the assessment of anal fistulae and its use may lead to a reduction in the recurrence rate due to inaccurate surgical assessment.
引用
收藏
页码:7 / 13
页数:7
相关论文
共 50 条
  • [31] Ligation of the Intersphincteric Fistula Tract (LIFT): A Sphincter-Saving Technique for Fistula-in-Ano
    Shanwani, A.
    Nor, Azmi M.
    Amri, Nil
    DISEASES OF THE COLON & RECTUM, 2010, 53 (01) : 39 - 42
  • [32] THE LIGATION OF INTERSPHINCTERIC FISTULA TRACT (LIFT) FOR FISTULA-IN-ANO: SPHINCTER SAVING TECHNIQUE.
    Shanwani, A.
    Azmi, M.
    Amri, N.
    DISEASES OF THE COLON & RECTUM, 2009, 52 (04) : 779 - 779
  • [33] OPTIMIZATION OF PROSTATIC MAGNETIC-RESONANCE-IMAGING TECHNIQUE
    POON, PY
    BRONSKILL, MJ
    POON, CS
    MCCALLUM, RW
    HENKELMAN, RM
    JOURNAL OF THE CANADIAN ASSOCIATION OF RADIOLOGISTS-JOURNAL DE L ASSOCIATION CANADIENNE DES RADIOLOGISTES, 1991, 42 (06): : 423 - 430
  • [34] Role of digital infrared thermal imaging in surgical management of fistula-in-ano
    Sedat Carkit
    Talha Sarigoz
    Mustafa Bilgili
    Tamer Ertan
    European Surgery, 2024, 56 : 21 - 26
  • [35] INTERPRETATION AND CLINICAL-APPLICATION OF MAGNETIC-RESONANCE-IMAGING
    BYDDER, GM
    IEEE TRANSACTIONS ON MAGNETICS, 1990, 26 (05) : 2089 - 2091
  • [36] INTERPRETATION OF THE MAGNETIC-RESONANCE-IMAGING SIGNAL FROM A FOAM
    MCCARTHY, MJ
    AICHE JOURNAL, 1990, 36 (02) : 287 - 290
  • [37] FISTULA-IN-ANO - ENDOANAL SONOGRAPHY VERSUS ENDOANAL MR-IMAGING
    HUSSAIN, SM
    STOKER, J
    ELEVELT, AJ
    SCHOUTEN, WR
    LAMERIS, JS
    RADIOLOGY, 1995, 197 : 379 - 379
  • [38] Role of digital infrared thermal imaging in surgical management of fistula-in-ano
    Carkit, Sedat
    Sarigoz, Talha
    Bilgili, Mustafa
    Ertan, Tamer
    EUROPEAN SURGERY-ACTA CHIRURGICA AUSTRIACA, 2024, 56 (1-2): : 21 - 26
  • [39] ACCURACY IN STAGING CARCINOMA OF THE BLADDER BY MAGNETIC-RESONANCE-IMAGING
    JOHNSON, RJ
    CARRINGTON, BM
    JENKINS, JPR
    BARNARD, RJ
    READ, G
    ISHERWOOD, I
    CLINICAL RADIOLOGY, 1990, 41 (04) : 258 - 263
  • [40] MAGNETIC-RESONANCE-IMAGING FOR THE DIAGNOSIS OF ESOPHAGO-ANEURYSMAL FISTULA
    NAGAO, Y
    OKANOUE, T
    KONO, I
    KASHIMA, K
    KADOWAKI, S
    INTERNAL MEDICINE, 1992, 31 (03) : 400 - 403